Használati útmutató Daikin FCQG60FVEB
Daikin
nincs kategorizálva
FCQG60FVEB
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Daikin FCQG60FVEB (12 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 6 ember találta hasznosnak és 3.5 felhasználó értékelte átlagosan 4.3 csillagra
Oldal 1/12

5
1
4
2
45
6
7
3
2
8
A
B
1 1
12
–14~24
–15~18
–14~21
–15~18
–19~21
–20~15.5
18-35
12-28
18-35
12-28
18-35
12-28
RQ71-100-125
21-32
14-23
21-32
14-23
10-30
10-30
10-27
RXS35-50-60
4MXS68-80
RZQG71-100-125-140
RR71-100-125
RXS35-50-60
3MXS52-68
3MXS52-68
5MXS90
4MXS68-80
5MXS90
≤80%
≤80%
≤80%
≤80%
≤80%
–10~46
–15~46
–10~46
–15~50
–5~46
°C DB
°C WB
°C DB
°C WB
RZQ200-250
18-35
14-28
≤80%
–5~46
°C DB
°C WB
°C DB
°C WB
°C DB
°C WB
°C DB
°C WB
°C DB
°C WB
°C DB
°C WB
°C DB
°C DB
°C DB
°C WB
18-35
14-28
RZQSG71-100-125-140
≤80%
–5~46
°C DB
°C WB
–9~21
–10~15
RQ71-100-125
10-27
°C DB
°C WB
°C DB
RZQG71-100-125-140
–14~21
–15~15
10-27
°C DB
°C WB
°C DB
–14~21
–15~15.5
10-27
°C DB
°C WB
RZQSG71-100-125-140
°C DB
°C DB
RZQ200-250
3
2
3
4
2+3
4
1
9
1
5
6
1
2
5
3
4

Operation manual
1
CONTENTS Page
What to do before operation .............................................................. 1
Important information regarding the refrigerant used ........................ 1
Safety considerations ........................................................................ 1
Names and functions of parts............................................................ 2
Operation range................................................................................. 2
Operation procedure.......................................................................... 3
Optimum operation ............................................................................ 3
Maintenance ...................................................................................... 3
Not a malfunction of the air conditioner............................................. 5
Troubleshooting ................................................................................. 6
Disposal requirements....................................................................... 6
The English text is the original instruction. Other languages are
translations of the original instructions.
WHAT TO DO BEFORE OPERATION (See figure 2)
Ask your dealer for installation and re-installation of the air
conditioner.
Incomplete installation performed by yourself may result in water
leakage, electric shock and fire.
Be sure only to use accessories made by Daikin which are
specifically designed for use with the equipment and have them
installed by a professional.
This operation manual is for the following systems with standard
control. Before initiating operation, contact your dealer for the
operation manual that corresponds to your system.
If your installation has a customised control system, ask your dealer
for the operation that corresponds to your system.
■ Heat pump type
This system provides cooling, heating, automatic, and fan
operation modes.
■ Straight cooling type
This system provides cooling, and fan operation modes.
IMPORTANT INFORMATION REGARDING THE
REFRIGERANT USED
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.
Refrigerant type: R410A
GWP
(1)
value: 1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.
SAFETY CONSIDERATIONS
To gain full advantage of the air conditioner's functions and to avoid
malfunction due to mishandling, we recommend that you read this
instruction manual carefully before use.
The precautions described herein are classified as WARNING and
CAUTION. They both contain important information regarding safety.
Be sure to observe all precautions without fail.
After reading, keep this manual in a convenient place so that you can
refer to it whenever necessary. If the equipment is transferred to a
new user, be sure also to hand over the manual.
Warning
■ Be aware that prolonged, direct exposure to cool or warm air
from the air conditioner, or to air that is too cool or too warm can
be harmful to your physical condition and health.
■ When the air conditioner is malfunctioning (giving off a burning
odour, etc.) turn off power to the unit and contact your local
dealer. Continued operation under such circumstances may
result in a failure, electric shocks or fire hazards.
■ Do not attempt to install or repair the air conditioner yourself.
Improper workmanship may result in water leakage, electric
shocks or fire hazards. Please contact your local dealer or
qualified personnel for installation and maintenance work.
■ Do not place objects, including rods, your fingers, etc., in the air
inlet or outlet. Injury may result due to contact with the air
conditioner's highspeed fan blades.
■ Consult your local dealer regarding what to do in case of
refrigerant leakage. When the air conditioner is to be installed in
a small room, it is necessary to take proper measures so that
the amount of any leaked refrigerant does not exceed the
concentration limit in the event of a leakage. Otherwise, this may
lead to an accident due to oxygen depletion.
■ Contact professional personnel about attachment of accessories
and be sure to use only accessories specified by the
manufacturer. If a defect results from your own workmanship, it
may result in water leaks, electric shock or fire.
■ Consult your local dealer regarding relocation and reinstallation
of the air conditioner. Improper installation work may result in
leakage, electric shocks or fire hazards.
FCQG35~140FVEB
FCQHG71~140FVEB
Split system air conditioners
Operation manual
THANK YOU FOR PURCHASING THIS DAIKIN AIR
CONDITIONER. CAREFULLY READ THIS OPERATION
MANUAL BEFORE USING THE AIR CONDITIONER. IT
WILL TELL YOU HOW TO USE THE UNIT PROPERLY
AND HELP YOU IF ANY TROUBLE OCCURS. AFTER
READING THE MANUAL, FILE IT AWAY FO R FUTURE
REFERENCE.
A Pair system or simultaneous operation system
B Multi system
1 Unit with remote controller
2 Unit without remote controller (When used as simultaneous
operation)
WARNING
If the warning is not observed, it may cause serious casualties.
CAUTION
If the caution is not observed, it may cause injury or damage to the
equipment.
Termékspecifikációk
Márka: | Daikin |
Kategória: | nincs kategorizálva |
Modell: | FCQG60FVEB |
Szüksége van segítségre?
Ha segítségre van szüksége Daikin FCQG60FVEB, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva Daikin
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
10 Január 2025
10 Január 2025
10 Január 2025
Útmutatók nincs kategorizálva
- nincs kategorizálva McGregor
- nincs kategorizálva Platinet
- nincs kategorizálva Akasa
- nincs kategorizálva SoundPEATS
- nincs kategorizálva Proline
- nincs kategorizálva Hotpoint
- nincs kategorizálva M-Audio
- nincs kategorizálva Avidsen
- nincs kategorizálva Croozer
- nincs kategorizálva Louis Tellier
- nincs kategorizálva Sunstech
- nincs kategorizálva Choice
- nincs kategorizálva Solid State Logic
- nincs kategorizálva X4 Life
- nincs kategorizálva Fisher
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025