Használati útmutató Entes EPM-06C-96
                    Entes
                    
                    Mérőberendezések
                    
                    EPM-06C-96
                
                                
                
                
                                
                Olvassa el alább 📖 a magyar nyelvű használati útmutatót Entes EPM-06C-96 (4 oldal) a Mérőberendezések kategóriában. Ezt az útmutatót 25 ember találta hasznosnak és 13 felhasználó értékelte átlagosan 5.0 csillagra
                        Oldal 1/4
                    
                    
                    
1
MULTIMETER
EPM-06 / 06C / 06CS
                                   INDEX
Precautions for Installation and Safe Usage.........................................................................1
Front  Panel and Usage of  Buttons.............................................................................1
General Information and Applications.............................................................................1
Using  the  Buttons............................................................................................2
Transformer Menu (Ctr / trn / Utr / ConnECtýon) ........................................................................2
User  Password  Settings  (Pin  Menu).......................................................................2
Act ivat ing  the  User  Password  (Pin  Act  Menu)......................................................2
Changing  the  User  Password  (Pin  CHg  Menu).........................................................2
Output  Setting  Menu  ..............................................................................3
Current  Setting  Menu  (SP  Current  Menu)  ................................................................3
High/Low  Current  Settings  (SP  Cur  Hý,  SP  Cur  Lo  Menu)..........................................3
Hysteresis  Settings  for High/Low  Currents (CUr Hý Hys,  CUr Lo  Hys  Menu).................3
Delay-on Time for  High/Low  Currents (Hý on dEL, Lo  on dEL Menu)..............................3
Delay-off Time for High/Low Currents (Hý oFF dEL, Lo oFF dEL Menu).......................................3
Start  and  Auto  Function  (StArt  dEL  and  Auto  rSt   Menu).........................................4
Instant  Trip  Function  (CUr ýnS trP Menu).................................................................4
Voltage  Setpoint  Menu  (SP  Volt  Menu)  ..................................................................4
High/Low  Voltage  Set tings  (SP  UoL  Hý,  SP  UoL  Lo  Menu)..................................4
Hysteresis  Settings  for  High/Low  Voltages  (UoL  Hý  Hys,  UoL  Lo  Hys  Menu)............5
Delay-on  Time  f or  High/Low  Volt ages  (Hý  on  dEL,  Lo  on  dEL  Menu).............5
Delay-of f  Time  for  High/Low  Voltages  (Hý  oFF  dEL,  Lo  oFF  dEL  Menu)................5
Frequency Menu .........................................................................................................6
High/Low  Frequency  Set tings  (Frq  Hý,  Frq  Lo  Menu).............................................6
Hysteresis Settings for High/Low Frequencies (Frq Hý HyS, Frq Lo HyS) ..............................6
Delay-on  /  Delay-off  Time  for  High/Low  Frequencies  (Frq  on  dEL,  Frq  oFF  dEL)....6
Phase Sequence (Voltage Sequence Menu) and Instant Trip (UoL ýnS trP Menu) Menu ........6
Erasing  the  Max.,  Min.  and  Max.  Demand  Values  (Reset  Menu)........................6
Demand Time for Demand and Max. Demand (dE tý Menu)....................................................7
Communucation  Menu  (RS-485)  .........................................................................7
Technical Features and Default Factory Settings ................................................................7
Connection  Diagram  ................................................................................................8
Output, SP Current and SP Volt menus are available for EPM-06C/06CS; RS-485 menu
is available for EPM-06CS.
Dimensions
Connection Diagram
MULTIMETER
EPM-06 / 06C / 06CS
8
A3794 / Rev.5
Available only for EPM-06C/06CS
Available only for EPM-06CS
Panel Cut-out
91mm
91mm
Type PR 19 (96x96)
   70mm
Wall      79.3mm
90mm
Tip 19
50mm
1  .......
Phase LEDs:The LEDs turn on when the voltage value, which is applied 
to one of the current inputs, reach 30 V
2  ....... First displays k LED (for L1). Measurement parameter is the unit of kilo 
when LED is turned on. ie: kA, kV
3  ....... Display for 
L1.
4  ....... Second displays k LED  . Measurement parameter(for L2 and neutral current)
is the unit of kilo when LED is turned on. ie: kA, kV
5  ....... Display for 
L2 and neutral current.
6  ....... Third displays k LED (for L3). Measurement parameter is the unit of kilo 
when LED is turned on. ie: kA, kV
7  ....... Display for 
L3.
8  ....... Displays network frequency when Hz LED is turned on.
9  .......  Display for frequency and Cos  (forEPM-06C/06CS).j
10 .......First warning output LED (Out1). Turned on when the output is activated.
11 .......Second warning output LED (Out2). Turned on when the output is activated.
12 .......Over  current   /  voltag e  warning  output   for  L1.  (EPM-06C/06CS)
13 .......Low  current  /  voltag e  warning  output  f or  L1.  (EPM-06C/06CS)
14 .......Over  current   /  voltag e  warning  output   for  L2.  (EPM-06C/06CS)
15 .......Low  current  /  voltag e  warning  output  f or  L2.  (EPM-06C/06CS)
16 .......Over  current   /  voltag e  warning  output   for  L3.  (EPM-06C/06CS)
17 .......Low  current  /  voltag e  warning  output  f or  L3.  (EPM-06C/06CS)
18 ....... Over current / frequency warning output for frequency (EPM-06C/06CS).
19 .......Low current / frequency warning output for frequency (EPM-06C/06CS).
20 .......   LED for max. instant current and voltage. Max. instant currents and H
voltages are displayed when this LED is turned on.
21 .......  LED for min. instant current and voltage. Min. instant currents and L
voltages are displayed when this LED is turned on.
22 .......  LED for max. demand. Max. demand values are displayed when this M
LED is turned on.
23 .......SET  button. It  is used to  enter  into  the  menu and  to  save the  values.
   If SET button is pressed for 3 sec. in the measurement mode, you can 
   enter into menus. This button is used for monitoring the max. (H), Min. 
   (L) current values and max. demand values in measurement mode.
24 ....... Downward selection button. And also switching between the phases for 
   EPM-06C/06CS.
25 .......Upward selection button. And also  switching  between  the  phases for
EPM-06C/06CS.
26 .......
ESC button. Displaying the neutral current during the measurement mode. 
Escaping from the menu. And also used for switching off the Latch function
while this function has activated.
27 ....... Over voltage warning LED which is 
displayed 
in fourth display.
28 ....... Low voltage warning LED which is 
displayed 
in fourth display.
29 .......These LEDs are used for which phase refers to measurement of voltage 
in 4th display.
30 ....... Display for monitoring the phase voltages (According to related phase).
31 .......This LED; indicates Cos  when L1, L2 or L3 activated for monitoring j
voltage values in 4th display.
Indicates average value of   are activated.inductive Cos  when L1-L2j
Indicates average value of   are activated.capacitive Cos  when L2-L3j
32 .......   LED for monitored phase in 4th display.k
~
Un
Out 2 Out 1
PK-26
I
L3
I
L2
I
L1
k l
K L
k l
K L
k l
K L
L1 L2 L3 N
GND A B TR
PR-19
kl
K L
kl
K L
k l
K L
IL1 IL2 IL3
Out 1 Out 2 GND B A TR
     70mm
     79.3mm
90mm
Type PR 19 (96x96)
     96mm
96mm
60.6
106.0
10.8 30.1 7.6 9.5
26.5 21.5
53.0
58.0
10.0
8.5
14.0
45.0
90.0
Type PK 26
*
**
30 9
1 10 11
12
13
14
15
16
17
27
28
18
19 23
21
20
26
24
25
22
29
8 31 32
5
4
6
7
2
3
112 14 163 5 7
28 27
30
26
23
24 25 21
20
22
931 8
19 18
4
6
15 1713
29
2
10
11
32
General information
EPM-06/06C/06CS is designed for measuring the below parameters in a 3-Phase
system. Phase current, frequency, neutral current and voltages (Phase-Phase and
Phase-Neutral).
EPM-06C/06CS;
Device has 2 warning 
output
 which named as Out1 and Out2. (NO-Normally Open)
Please refer to Output menu for the functions of the relays.
Note: For CT-25 models:
Summary of the Contact Operations
Voltage
Frequency
Current
Phase Seq.
Voltage
Frequency
Current
Under
Under
Under
Over
Over
Over
ALTERNATIVE 2 (H-L)
Current
Voltage
Frequency
Phase Seq.
Under/Over
Under/Over
Under/Over
ALTERNATIVE 1 (U-I)
Out 1
Out 2
-->
-->
-->
-->
-->
-->
-->
-->
-->
Failure to follow those instructions will result in death or serious injury.
- Disconnect all power before working on equipment.
- When the device is connected to the network, do not remove the front
  panel.
- Do not try to clean the device with solvent or the like.Only clean with dry
  cloth.
- Verify correct terminal connections when wiring.
- Electrical equipment should be serviced only by your component seller.
- Only for rack panel mounting.
- Fuse must be F type and limit value doesnt exceed 1A.
In CT-25 (120A) compliant models, only CT-25 current transformer
must be used.
Other type of CTs have a high risk to damage to device.
PRECAUTIONS FOR INSTALLATION AND SAFE USE
Valid for EPM-06C/06CS
No responsibility is assured by the manufacturer or any of its subsidiaries
for any consequences arising out of the use of this material.
17 18 19 20
RS485
System
N
L1
L2
L3
1 A
L1
L2
L3
N
Current Measurement Inputs
Auxiliary
Supply
1 2 3 4 5 6
11 12
Output Relay
13 14 1 165
Choose according to
contactor current
7 8 9 10
Voltage Measurement Inputs
k: When CT-25 is used, Red cable is connected to k terminal.
l: When CT-25 is used, Black cable is connected to l terminal.
N
L1
L2
L3
1
 A
Current Measurement
Inputs
Auxiliary
Supply
Relay utput
System
Choose according to
contactor current
Voltage Measurement
Inputs
RS485
Termékspecifikációk
| Márka: | Entes | 
| Kategória: | Mérőberendezések | 
| Modell: | EPM-06C-96 | 
Szüksége van segítségre?
Ha segítségre van szüksége Entes EPM-06C-96, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Mérőberendezések Entes
                        
                         26 Augusztus 2024
                        
                    
                                                            
                        
                         26 Augusztus 2024
                        
                    
                                                            
                        
                         26 Augusztus 2024
                        
                    
                                                            
                        
                         26 Augusztus 2024
                        
                    
                                                            
                        
                         26 Augusztus 2024
                        
                    
                                                            
                        
                         26 Augusztus 2024
                        
                    
                                                            
                        
                         22 Augusztus 2024
                        
                    
                                                            
                        
                         22 Augusztus 2024
                        
                    
                                                            
                        
                         22 Augusztus 2024
                        
                    
                                                            
                        
                         22 Augusztus 2024
                        
                    
                                                            Útmutatók Mérőberendezések
- Mérőberendezések Lund
- Mérőberendezések Noyafa
- Mérőberendezések Vemer
- Mérőberendezések GQ
- Mérőberendezések Topex
- Mérőberendezések Oregon Scientific
- Mérőberendezések Kemo
- Mérőberendezések Chauvin Arnoux
- Mérőberendezések MSW
- Mérőberendezések Eurolite
- Mérőberendezések Soehnle
- Mérőberendezések Perel
- Mérőberendezések Flex
- Mérőberendezések Electronics International
- Mérőberendezések Circutor
Legújabb útmutatók Mérőberendezések
                        
                         3 Április 2025
                        
                    
                                                            
                        
                         3 Április 2025
                        
                    
                                                            
                        
                         3 Április 2025
                        
                    
                                                            
                        
                         3 Április 2025
                        
                    
                                                            
                        
                         3 Április 2025
                        
                    
                                                            
                        
                         3 Április 2025
                        
                    
                                                            
                        
                         3 Április 2025
                        
                    
                                                            
                        
                         3 Április 2025
                        
                    
                                                            
                        
                         3 Április 2025
                        
                    
                                                            
                        
                         3 Április 2025