Evolutionautopilotset-upand
commissioningwithp70/p70R
p70&p70RandEvolutionautopilot—
overview
Thisdocumentwillguideyouthroughthestepsrequiredin
setting-upandcommissioningyourEvolutionautopilotsystem
usingaRaymarinep70/p70Rautopilotcontrolhead.
IfyouareanexistinguserofRaymarineautopilotsystems,
thisdocumentwillalsohelpyoutounderstandthedifferences
betweenthecommissioningprocessforexistingSPXautopilot
systems,andtheEvolutionautopilotsystem.Forexample,there
areanumberofexistingset-upandcommissioningstepsthat
youmightalreadybefamiliarwithforSPXsystems,whichare
nolongerrequiredorareslightlydifferentforEvolutionautopilot
systems.
Evolutionautopilotinstallation
ForinformationoninstallingandconnectinganEvolutionautopilot
system,refertotheinstallationinstructionsthataccompanythe
EV-1andEV-2units,asappropriate.
Evolutionautopilotoperationwithp70
&p70R
Generaloperationofthep70/p70RisthesameforEvolution
autopilotsystemsasitiswithexistingSPXautopilotsystems.
Refertodocumentnumber81355forp70/p70Roperation
instructions.Thisdocumentissuppliedwithallp70/p70Runits.
YoucandownloadthelatestversionfromtheRaymarinewebsite:
www.raymarine.com.
Autopilotcommissioning—main
differencesbetweenEvolutionand
SPXsystems
TheEvolutionsystemprovidesanumberoffeaturestoimprove
uponthecommissioningprocessrequiredbyexistingSPXand
someotherautopilotsystems.
•Built-inheadingandattitudesensor—noadditionaluxgate
compassrequired.
•Automaticset-up—theruddergain,counterrudder,manual
compasscalibrationandautolearnsettingsrequiredforexisting
SPXsystemsarenolongerrequired.Thisresultsinagreatly
simplieddocksidecalibrationprocessforEvolutionautopilot
systems.
Autopilotresponselevels
TheEvolutionautopilotsystemfeaturesanumberofdifferent
responselevelstohelpyouquicklycongurethesystemfor
optimumperformanceforthecurrentconditions.
Theavailableresponselevelsare:
•Leisure—suitableforlongpassageswheretightheading
controlisnotcritical.
•Cruising—goodcourse-keepingwithoutoverworkingthepilot.
•Performance—emphasisontightheadingcontrol.
YoucanchangetheresponselevelatanytimebyselectingMENU
>ResponseLevel.ThenselectSavetokeepthechanges.
Initialsetupandcommissioning
Commissioningpre-requisites
Beforecommissioningyoursystemforthersttime,checkthat
thefollowingprocesseshavebeencarriedoutcorrectly:
•Autopilotsysteminstallationcompletedinaccordancewiththe
Installationinstructions.
•SeaTalk ng networkinstalledinaccordancewiththeSeaTalk ng
ReferenceManual.
•Wheretted,theGPSreceiverhasbeeninstalledand
connectedinaccordancewiththeassociatedInstallation
instructions.
Checkalsothatthecommissioningengineerisfamiliarwiththe
installationandcomponentsoftheautopilotsystemincluding:
•Vesseltype.
•Vesselsteeringsysteminformation.
•Whattheautopilotwillbeusedfor.
•Systemlayout:componentsandconnections(youshouldhave
aschematicofthevessel’sautopilotsystem).
Initialset-up
Initialset-upinvolvesthefollowingsteps:
Important:Beforeproceedingwiththeinitialset-upor
commissioningofap70/p70R,ensurethatyourp70/p70Ris
runningthelatestsoftware.p70/p70RoperationwithEvolution
systemsrequiresp70/p70Rsoftwareversion2orlater.Refer
tohttp://www.raymarine.co.uk/view/?id=797todownloadthe
latestsoftwareandviewinstructionsonhowtoupgradethe
softwareonyourp70/p70R,usingamultifunctiondisplay.
1.Power-upyourp70/p70R.
2.Specifyyourpreferredlanguageandappropriatevesseltype,
usingtheSet-upwizard.
3.Completethedocksidecalibrationprocess,usingthe
Docksidewizard:
Forvesselswithout
arudderreference
transducer:
Forvesselswitharudder
referencetransducer:
DriveTypeselectionDriveTypeselection
AlignRudder(rudderalignment)
RudderLimitsettingRudderLimitsetting
HardOverTime(ifyoudonot
alreadyknowyourhardovertime,
youshouldskipthisstepinthe
DocksideWizardandenterthe
valuemanuallyafterwards.
RudderDrivecheckRudderDrivecheck
4.Oncethedocksidewizardiscomplete,specifythehard-over
time(onlyappliestosystemsthatdoNOTincludearudder
referencetransducer).
5.Familiarizeyourselfwiththeimportantinformationinthis
documentrelatedtocompasslinearization.Followthe
guidelinesprovidedtoensurethattheprocessiscompleted
successfully.
6.Onceyou’vesuccessfullycompletedallthestepslistedabove,
youshouldalsofamiliarizeyourselfwiththeinformation
relatedtocompasslock.
Documentnumber:82285-5
Termékspecifikációk
| Márka: | Raymarine |
| Kategória: | nincs kategorizálva |
| Modell: | Evolution p70 |
Szüksége van segítségre?
Ha segítségre van szüksége Raymarine Evolution p70, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva Raymarine
12 Január 2025
15 Augusztus 2024
14 Augusztus 2024
14 Augusztus 2024
14 Augusztus 2024
14 Augusztus 2024
13 Augusztus 2024
13 Augusztus 2024
12 Augusztus 2024
12 Augusztus 2024
Útmutatók nincs kategorizálva
- nincs kategorizálva Rikon
- nincs kategorizálva SXT
- nincs kategorizálva Rittal
- nincs kategorizálva Sanus Systems
- nincs kategorizálva Hoshizaki
- nincs kategorizálva 2box
- nincs kategorizálva Eventide
- nincs kategorizálva Sensative
- nincs kategorizálva Generac
- nincs kategorizálva BenQ
- nincs kategorizálva Kernau
- nincs kategorizálva Connect IT
- nincs kategorizálva Parisot
- nincs kategorizálva Bebe Confort
- nincs kategorizálva V-Tone
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025