Használati útmutató Stanley S100

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Stanley S100 (50 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 13 ember találta hasznosnak és 8 felhasználó értékelte átlagosan 4.9 csillagra

Oldal 1/50
9
REV A 08STHT77403
S100
2
11
>
3
3
3
33
sec
sec
sec
sec
sec
9
2 36 7
11
>
3
3
3
33
sec
sec
sec
sec
sec
4 5
3
3
3
33
sec
sec
sec
sec
sec
177403
1
Stanley Stud Sensor 100
The Stud Sensor 100 uses electronic signals to locate the edges of
studs, joists or live AC wires through drywall or other common building
materials. Once the edge of a stud has been detected, the Stud Sensor
100 displays red LEDs and sounds an audible tone. A marking channel
allows you to easily note the stud edges on the wall.
Note: Read all instructions prior to operating the Stud Sensor 100 and
DO NOT remove any labels from the tool.
WARNING:
Protect Your Eyes, Wear Safety Goggles.
Usage
Detecting Wood / Metal Studs
2Hold the Stud Sensor 100 at
against the surface, making rm
contact.
3 Press in and hold the activation
button. The green and top red LED
will light.
Note:The unit cannot be moved
before calibration is complete.
6When it detects the stud edge,
the top LED will go on and an
audible tone will sound. Use the
marking channel located at the top
of the unit to mark the stud edge.
7 Repeat the above steps from
the other side of the stud. Coming
from the opposite direction, mark
the other edge of the stud.
OPERATING INSTRUCTIONS
Battery
1Open door on back of unit and connect a 9 volt
battery (not included)to clip. Put battery back into
case and close back battery door.
Note:Recommend to replace a new 9 volt
battery when low battery - fl ashing green LED.
11 If the red LED stays lit, move the Stud
Sensor 100 to a different location and try again.
Releasing the activation button will turn off the
sensor.
Note:While calibrating, the Stud Sensor 100
must not be placed directly over a stud, dense
material such as metal, or over a wet or newly
painted area, or it will not properly calibrate.
9Slide the Stud Sensor 100 slowly across the surface in a straight
line. As it detects a stud, the red LEDs will go on.
Marking Channel
Live Wire Warning LED
LED Display
Activation Button
Self-Calibration Complete /
Low Battery Indicator
4 When the red LED goes off, the
unit is calibrated.
5Keep holding the activation
button during all of the following
procedures.
Note:Once the Activation button
is released, the unit shuts off.
Live Wire Detected
STUD Detected

Értékelje ezt az útmutatót

4.9/5 (8 Vélemények)

Termékspecifikációk

Márka: Stanley
Kategória: nincs kategorizálva
Modell: S100

Szüksége van segítségre?

Ha segítségre van szüksége Stanley S100, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Stanley

Stanley
Stanley

Stanley SL229 Útmutató

4 Szeptember 2024
Stanley

Stanley SL227 Útmutató

4 Szeptember 2024
Stanley

Stanley SHR263 Útmutató

4 Szeptember 2024
Stanley
Stanley
Stanley

Stanley SFMCN616 Útmutató

25 Augusztus 2024

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva

Moza

MOZA SR-P Útmutató

10 Április 2025
Caterchef
Ifm

IFM E40581 Útmutató

9 Április 2025
Livn

Livn Bolt Útmutató

9 Április 2025
Livn

Livn Beats Útmutató

9 Április 2025
Ifm

IFM O3R252 Útmutató

9 Április 2025