In-Line Network
Surge Protector,
10 Gbps, Cat6a
Model: B110-SP-10G
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2022 Tripp Lite. All rights reserved.
Quick Start Guide
WARRANTY REGISTRATION
Register your product today and be
automatically entered to win an ISOBAR
®
surge protector in our monthly drawing!
tripplite.com/warranty
Español 9 • Français 17 • Русский 25
2
B110-SP-10G 10 Gbps In-Line Network Surge Protector
Grounding Wire
Mounting Screws (x4)
Screw Anchors (x4)
Grounding Wire Screw
Quick Start Guide
Protects your network equipment’s inputs and outputs against electro-
static discharge (ESD), power surges and cable discharge events
Meets the following IEC regulations:
o IEC 61000-4-2: Indirect discharge (4kV), direct discharge (8kV)
o IEC 61000-4-5 (Lightning) 2kA (8/20µs), 1kV (8/20µs)
Easy to connect between network source and device using
standard Cat5/5e/6/6a/8 cabling
Rapid reaction time under 1 ns helps prevent damage from
lightning/power surges
Supports Ethernet network data transmission speeds up to 10 Gbps
Plug-and-play operation with no software required for easy,
immediate installation
Supports distance between the B110-SP-10G and equipment up
to 330 ft. (100 m)
Compliant with the Federal Trade Agreements Act (TAA) for GSA
(General Services Administration) Schedule and other federal
procurement contracts
Package Includes
Product Features
3
Note: The following instructions assume that two network devices are
currently connected together.
Single Device Protection:
1. Disconnect the installed patch cable from the device you wish
to protect and attach it to the “Cable End” of the In-Line 10G
Network Surge Protector.
2. With a user-supplied Cat5/5e/6/6a/8 patch cable, connect the
device to be protected to the “Equipment End” of the In-Line
10G Network Surge Protector.
Note: For best protection performance, the patch cable between
the “Equipment End” on the B110-SP-10G and the equipment
to be protected should not exceed 330 ft. (100 m). Tripp Lite’s
N261-Series Cat6a Snagless Patch Cables are recommended.
3. Connect the ground wire to the In-Line 10G Network Surge
Protector and then to earth ground.
Installation

Termékspecifikációk

Márka: Tripp Lite
Kategória: nincs kategorizálva
Modell: B110-SP-10G

Szüksége van segítségre?

Ha segítségre van szüksége Tripp Lite B110-SP-10G, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Tripp Lite

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva

MOZA

MOZA SR-P Útmutató

10 Április 2025
CaterChef

CaterChef 445001 Útmutató

9 Április 2025
IFM

IFM E40581 Útmutató

9 Április 2025
Livn

Livn Bolt Útmutató

9 Április 2025
Livn

Livn Beats Útmutató

9 Április 2025
IFM

IFM O3R252 Útmutató

9 Április 2025