Használati útmutató APC Switched Rack PDU
APC
nincs kategorizálva
Switched Rack PDU
Olvassa el alább 📖 a magyar nyelvű használati útmutatót APC Switched Rack PDU (18 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 14 ember találta hasznosnak és 7.5 felhasználó értékelte átlagosan 4.1 csillagra
Oldal 1/18

Overview and Specifications
990-3456B Release Date: 11/15/21
APC
70 Mechanic Street
02035 Foxboro, MA
USA
www.apc.com
As standards, specifications, and design change from time
to time, please ask for confirmation of the information
given in this publication.
© 2021
Schneider Electric. APC, the APC logo, and
EcoStruxure are trademarks of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their
respective owners.
Switched Rack Power Distribution Unit (AP8653)
Overview
The APC Switched Rack Power Distribution
Unit (PDU) distributes power to devices in a
rack. The PDU measures total load plus
phase, bank, and outlet load. In addition,
configured users can control the state of the
outlets. You can access the PDU through
Web, Telnet, SNMP, SSH, or EcoStruxure™
IT Expert interfaces for comprehensive
control and monitoring functionality.
Outlets. The Rack PDU has twenty-one (21)
IEC-320-C13 and three (3) IEC-320-C19
locking outlets . (The locking feature is
compatible with APC locking input cords and
APC locking jumper cords.)
Overcurrent protection. The Rack PDU
has two (2) 16 A, 1-pole hydraulic-magnetic
circuit breakers
1.
Display interface. The liquid crystal display
(LCD) and input buttons allow you to
monitor current, power, and voltage
measurements of the Rack PDU. Local
communication can be established through
the serial port , and remote communication
through the network port . The USB port
allows for firmware upgrades, and the CAN
ports enable data transfer for future
expansion options. The environmental sensor
port allows for monitoring of the
temperature and humidity of the room or
enclosure.
Power cord. The 3.0-m (10-ft) power cord
terminates with a 32 A, 3-pin IEC-309
connector
:.
Toolless mounting: The Rack PDU has two toolless mounting pegs for 0 U mounting
capability in a rack or enclosure.
TRIPPED
TRIPPED
pdu0558a
Network
Main
Menu
Scroll
Select
In Serial
USB
Out
Temp/Humidity
10
/
100
x
Reset
Warning
OK
Overload
By ElectricScheider
Rack PDU
Network
Main
Menu
Scroll
Select
In Serial
USBOut
Temp/Humidity
10/
100
x
Reset
Warning
OK
Overload
By ElectricScheider
Rack PDU
Termékspecifikációk
| Márka: | APC |
| Kategória: | nincs kategorizálva |
| Modell: | Switched Rack PDU |
Szüksége van segítségre?
Ha segítségre van szüksége APC Switched Rack PDU, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva APC
9 Április 2025
29 Március 2025
29 Március 2025
29 Március 2025
11 December 2024
11 December 2024
5 December 2024
15 Október 2024
14 Október 2024
4 Október 2024
Útmutatók nincs kategorizálva
- GoClever
- Advance
- Sifflus
- Quantum
- Kitronik
- Fujifilm
- Boori
- Radio Flyer
- Eoslift
- Urbanista
- Veritas
- Tescoma
- Anybus
- Drawmer
- Soma
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025