Használati útmutató APSystems DS3
Olvassa el alább 📖 a magyar nyelvű használati útmutatót APSystems DS3 (22 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 14 ember találta hasznosnak és 7.5 felhasználó értékelte átlagosan 4.9 csillagra
Oldal 1/22

Please scan this QR code to have
access to our APPs and Products
informaon
APsystems DS3 series
DS3-L and DS3 Microinverters
EMEA region
Installaon Manual
ALTENERGY POWER SYSTEM Inc.
emea.APsystems.com
APsystems
Cypresbaan 7, 2908 LT, Capelle aan den Ijssel
The Netherlands
Tel: +31- - info.emea@APsystems.com10 2582670 EMAIL:
Rue des Monts d’Or, ZAC de Folliouses Sud-Les Echets 01700 Miribel,
France
TEL: +33- - - -40 EMAIL:info.emea@APsystems.com481 65 60
© All Rights Reserved

APsystems DS3 series Installaon/User Manual
1
Table of Contents
1.Important Safety Instrucons ...................................................................................................... 2
1.1 Safety Instrucons ...................................................................................................................................... 2
1.2 Radio Interference Statement .................................................................................................................... 3
1.3 Symbols replace words on the equipment, on a display, or in manuals ................................................... 4
2.APsystems Microinverter System Introducon............................................................................ 5
2.1 Key elements of an APsystems system ....................................................................................................... 5
2.2 The advantages of an APsystems system ................................................................................................... 6
3.APsystems Microinverter DS3 series Introducon ....................................................................... 7
3.1 Characteriscs of the DS3 microinverter .................................................................................................... 7
3.2 Features of the DS3 microinverter.............................................................................................................. 7
4.APsystems Microinverter System Installaon.............................................................................. 8
4.1 Addional accessories supplied by APsystems .......................................................................................... 8
4.2 Other required accessories not supplied by APsystems ............................................................................ 8
4.3 Installaon Procedures ............................................................................................................................... 9
4.3.1 Step 1 - Verify that grid voltage is matching with microinverter rang ......................................... 9
4.3.2 Step 2 Y3 AC Bus Cable distribuon– ............................................................................................. 9
4.3.3 Step 3 - Attach the APsystems Microinverters to the Racking ........................................................ 9
4.3.4 Step 4 - Ground the system ............................................................................................................ 10
4.3.5 Step 5 - Connect the APsystems microinverter to AC bus cable ................................................... 10
4.3.6 Step 6 - Install a Bus Cable End Cap at the end of AC bus cable ....................................................11
4.3.7 Step 7 - Connect APsystems Microinverters to the PV Modules .................................................. 12
4.3.8 Step 8 - Complete the APsystems installaon map ...................................................................... 13
4.3.9 Step 9 - Warning Noce ................................................................................................................. 13
5. Microinverter system operang instrucons ............................................................................ 14
6.Troubleshoong ......................................................................................................................... 15
6.1 Status Indicaons and Error Reporng .................................................................................................... 15
6.1.1 Start up LED .................................................................................................................................... 15
6.1.2 Operaon LED ................................................................................................................................ 15
6.1.3 GFDI Error ....................................................................................................................................... 15
6.2 ECU_APP .................................................................................................................................................... 15
6.3 Installer EMA (web portal or EMA Manager APP) ................................................................................... 15
6.4 Trouble Shoong Guide ............................................................................................................................ 15
6.5 APsystems Technical Support ................................................................................................................... 16
6.6 Maintenance ............................................................................................................................................. 16
7.Replace a microinverter............................................................................................................. 17
8.Technical Data ............................................................................................................................ 18
8.1 DS3 series Microinverter Datasheet ......................................................................................................... 19
9. DS3 series - Wiring Diagram ..................................................................................................... 20
9.1 Sample Wiring Diagram - Single Phase ..................................................................................................... 20
10 APsystems Microinverter & Energy Communication Unit Installaon Map ............................. 21

APsystems DS3 series Installaon Manual
2
1.Important Safety Instrucons
This manual contains important instrucons to follow during installaon and maintenance of the APsystems
Photovoltaic Grid-connected Microinverter. To reduce the risk of electrical shock and ensure a safe installaon and
operaon of the APsystems Microinverter, the following symbols appear throughout this document to indicate
dangerous condions and important safety instrucons.
Specicaons are subject to change without noce. Please ensure you are using the most recent update found at
hps://emea.apsystems.com/resources/library/
This indicates informaon that is important for opmized microinverter operaon. Follow these instrucons
closely.
1.1 Safety Instrucons
Only qualified professionals should install and/or replace APsystems Microinverters.
Perform all electrical installaons in accordance with local electrical codes.
Before installing or using the APsystems Microinverter, please read all instrucons and cauonary markings
in the technical documents and on the APsystems Microinverter system and the solar array.
Do NOT disconnect the PV module from the APsystems Microinverter without rst disconnecng the AC
power.
Be aware that the body of the APsystems Microinverter is the heat sink and can reach a temperature of 80°C.
To reduce risk of burns, do not touch the body of the Microinverter.
Do NOT attempt to repair the APsystems Microinverter. If the micro is suspected to be faulty, please contact
your local APsystems Technical Support to start troubleshoong and obtain a RMA (Return Merchandise
Authorizaon) number to start the replacement process if needed. Damaging or opening the APsystems
Microinverter will void the warranty.
Cauon!
When connecng a microinverter, it is recommended to rst connect the AC Bus cable to the ground then
connect the AC connector to ensure proper earthing of the micro-inverter, then do the DC connecons. When
disconnecng a microinverter disconnect the AC by opening the branch circuit breaker rst but maintain the
protective earthing conductor in the branch circuit breaker connected to the microinverter, then disconnect
the DC inputs.
Please install AC breakers on the AC side of the inverter.
Termékspecifikációk
Márka: | APSystems |
Kategória: | nincs kategorizálva |
Modell: | DS3 |
Szüksége van segítségre?
Ha segítségre van szüksége APSystems DS3, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva APSystems
1 Október 2024
3 Szeptember 2024
3 Szeptember 2024
3 Szeptember 2024
28 Augusztus 2024
28 Augusztus 2024
Útmutatók nincs kategorizálva
- nincs kategorizálva Gre
- nincs kategorizálva Armcross
- nincs kategorizálva Auto Joe
- nincs kategorizálva Nowsonic
- nincs kategorizálva Peerless-AV
- nincs kategorizálva Simpark
- nincs kategorizálva Icy Dock
- nincs kategorizálva Mimo Monitors
- nincs kategorizálva Premier
- nincs kategorizálva Meradiso
- nincs kategorizálva CDVI
- nincs kategorizálva Projecta
- nincs kategorizálva Tube-Tech
- nincs kategorizálva Insect Lore
- nincs kategorizálva Steren
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025