SHATTERPRO 3 GLASSBREAK DETECTOR
INSTALLATION I NSTRUCTIONS
- 1 -
Figure 1 - Mounting Locations
Figure 2 - Multiple Window Coverage
Microphone
LED
Figure 3 - Attaching the Cover
7. Connect the system wires to the appropriate screw terminals on the base
and tighten the screws.
8. Replace the cover as follows:
- Round housing: Line up the tabs on the base with the correspond-
ing tabs on the cover, press together and turn clockwise until the
cover snaps firmly into place. See Figure 3.
- Rectangle housing: Press the cover back down over the detector
until the cover snaps firmly into place.
9. Apply power. The red LED should flash once.
10. Test the detector. See Testing the Detector.
F
NL
D
I
S
DK
DESCRIPTION
The ShatterPro 3 is an acoustic glassbreak detector designed to detect
breaking glass from framed windows in the perimeter of a building. The
detector is mounted in the building interior and uses a power supply from a
12 VDC control panel. The detector is available in either a low-profile round
housing or a rectangular housing that connects easily to a single-gang box.
SELECTING A L OCATION FOR THE D ETECTOR
Mount the detector on ceilings or on walls opposite or adjacent the window
to be protected. See Figure 1. Use the following guidelines to determine the
best location to install the detector.
wMount at least 1m from the glass windows being protected.
wWindows must be at least 30 x 60 cm square.
wAvoid locations where lined, insulating or sound deadening curtains are
used.
wMount 30cm away from wall corners.
wAvoid locations where interior closed wooden shutters are used.
wLocate in a suitable environment as follows:
- Temperature between 0° and 50°C
- Humidity between 10 and 90% non-condensing
wMount the detector on a stable surface up to 7.6 m from the farthest point
on the glass surface. See Figure 1.
wAvoid locations that expose the detector to possible false alarm sources
such as: Glass airlocks and vestibule areas, kitchens, residential car
garages, small utility rooms, stairwells, bathrooms, small acoustically live
rooms, air vents.
SELECTING THE B EST L OCATION FOR M ULTIPLE W INDOW
COVERAGE
The detector has a 360° coverage pattern that can cover several windows
in a single room as follows (See Figure 2):
wDraw an imaginary line from the center of each window to be covered
in towards the center of the room.
wMount the detector as close to where the lines intersect as possible.
wDo not mount the detector at more than a 60° angle from the center of any
window to be protected.
INSTALLING THE D ETECTOR
All wiring must conform to national approvals.
Important ! If you are unsure about a location, connect a 9 V battery to the
detector and test it before permanently mounting. See Testing the Detector.
To install the detector:
1. Run the security system wiring to the detector location.
2. Remove the front cover as follows:
- Round housing: Press the release tab on the lip of the base, twist
the cover counterclockwise, and lift off.
- Rectangle housing: Gently pry up the slot on the bottom of the
cover to unlock the cover. Lift up the cover until it latches in the open
position.
3. Set the range with J3 on the circuit board. See Setting the Range.
4. Remove the appropriate wiring and mounting knockout holes from the
base. See Figure 4.
5. Pull the wires through the knockout holes and use two screws to attach
the base to the surface. Use wall anchors if necessary.
6. Strip 1 cm of insulation from each wire.
GB
Ceiling
mount
Detector
60° max.
60° max.
7.6 m
max.
7.6 m
max.
Ceiling
mount
Wall
mount
Termékspecifikációk
| Márka: | Aritech |
| Kategória: | Biztonság |
| Modell: | SHATTERPRO 3 |
Szüksége van segítségre?
Ha segítségre van szüksége Aritech SHATTERPRO 3, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Biztonság Aritech
16 Január 2025
13 Augusztus 2024
12 Augusztus 2024
4 Augusztus 2024
30 Július 2024
16 Július 2024
14 Július 2024
4 Július 2024
4 Július 2024
4 Július 2024
Útmutatók Biztonság
- Biztonság Nor-tec
- Biztonság Fracarro
- Biztonság V-TAC
- Biztonság Audiovox
- Biztonság Eufy
- Biztonság Trust
- Biztonság Powerfix
- Biztonság Powermax
- Biztonság Goobay
- Biztonság FlinQ
- Biztonság Ednet
- Biztonság Technaxx
- Biztonság Plustek
- Biztonság Kocom
- Biztonság Profile
Legújabb útmutatók Biztonság
15 Január 2025
15 Január 2025
12 Január 2025
11 Január 2025
5 Október 2024
23 Szeptember 2024
23 Szeptember 2024
23 Szeptember 2024
22 Szeptember 2024
20 Szeptember 2024