Használati útmutató Atlona AT-VTP-800
Atlona
nincs kategorizálva
AT-VTP-800
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Atlona AT-VTP-800 (12 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 14 ember találta hasznosnak és 7.5 felhasználó értékelte átlagosan 4.9 csillagra
Oldal 1/12

Installation Guide
AT-VTP-800
1
Velocity 8” Touch Panel
AT-VTP-800
1 x AT-VTP-800
1 x Metal mounting plate
4 x Mounting screws
1 x Wall installation template
1 x 2-gang mud ring
1 x Installation Guide
Package Contents
Operating Notes
• The Velocity 8” Touch Panel (AT-VTP-800) must be on the same network as the Velocity
Gateway (AT-VGW-HW) or it will be unable to sync for control.
• The AT-VTP-800 is PoE capable, to power the unit, simply plug it into a 802.3at compatible
network switch. If the network switch is not PoE capable, a PoE injector (purchased separately)
can be used.
IMPORTANT: Velocity Gateway (AT-VGW-HW) must be set up before the AT-VTP-800 is
fully functional.
The Atlona AT-VTP-800-BL and AT-VTP-800-WH are 8” touch panels in black and white,
respectively, for the Atlona Velocity™ Control System. They feature contemporary, rened styling
for modern presentation environments with 1280x800 native resolution, and a capacitive glass
surface that supports multi-touch and gesture interactions. These touch panels conveniently
install into a wall or furniture via a US two-gang opening. Also available is the optional AT-VTP-
TMK tabletop mounting kit for placement on a meeting table or lectern. The VTP-800-BL and
VTP-800-WH feature Power over Ethernet (PoE), enabling a single network connection for data
and power. Setting up the touch panels is eortless as the AV control GUI is automatically
uploaded from the Velocity Control Gateway processor during system conguration.

Installation Guide
AT-VTP-800
2
The AT-VTP-800 has two mounting options. In-wall or an optional stand (available through atlona.
com).
Mounting Instructions
In-wall
1 Use the included wall mount template to create a hole in the wall the correct 2-Gang size for
the unit.
2 Install the back box (not included) or mud ring (included) into the wall.
3 Screw the included metal mounting plate into the mud ring using the 4 included screws.
4 Remove the two screws from the bottom of the touch panel.
5 Run the Ethernet cable through the mud ring and metal mounting plate.
6 Connect the Ethernet and/or power cable into the back of the touch panel.
7 Line up the touch panel with the mounting plate and thread the metal hooks into the four
holes on the back of the panel.
8 Gently press the touch panel down to ensure it is fully seated on the mounting plate.
9 Replace the two bottom screws to secure the touch panel to the metal mounting plate.

Installation Guide
AT-VTP-800
3
Stand
1 Place the stand on the table/desk
a If the rubber no slip guard is not secure enough, use four wall screws and thread them
though the four holes on the bottom of the unit and into the desk/table.
2 Thread the Ethernet cable through the bottom rounded hole on the back of the stand and
back out the rectangular hole on the front of the stand.
3 Plug the Ethernet cable into the back of the touch panel.
4 Place the touch panel on the stand, pushing the excess cable back through the stand at the
same time as resting the back panel of the touch panel in the rectangular front hole of the
stand.
5 Secure the touch panel to the stand using the four stand screws (included in the stand box).
a Thread the screws through the 4 pre-drilled holes in the front of the stand into the four
screw holes on the back of the touch panel.
NOTE: Tight the screws by hand. To avoid damage to the touch panel, do not
overtighten.
Installation and Set Up
1 Connect the Ethernet cable into the back of the unit.
a If the Ethernet cable is connected to a non PoE switch, use a PoE injector using 802.3at
(purchased separately).
2 Secure the unit in either the wall or optional stand, as explained in the mounting instructions.
3 The Velocity logo will display during the booting process and will go directly into setup.
Press to start the setup process.CONTINUE
NOTE: Installation of the Velocity Touch Panel can only be done after the VGW-HW
has been set up. View the AT-VGW-HW Installation Guide and Velocity Manual for
instructions.
Termékspecifikációk
Márka: | Atlona |
Kategória: | nincs kategorizálva |
Modell: | AT-VTP-800 |
Szüksége van segítségre?
Ha segítségre van szüksége Atlona AT-VTP-800, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva Atlona
1 Április 2025
14 Január 2025
14 Január 2025
11 Január 2025
11 Január 2025
11 Január 2025
11 Január 2025
11 Január 2025
11 Január 2025
11 Január 2025
Útmutatók nincs kategorizálva
- nincs kategorizálva Pressalit
- nincs kategorizálva UAvionix
- nincs kategorizálva Cudy
- nincs kategorizálva G.Skill
- nincs kategorizálva JDC
- nincs kategorizálva Digitech
- nincs kategorizálva DMax
- nincs kategorizálva Hooker
- nincs kategorizálva Cablexpert
- nincs kategorizálva Absco
- nincs kategorizálva Motu
- nincs kategorizálva One Stop Systems
- nincs kategorizálva Pinolino
- nincs kategorizálva Umidigi
- nincs kategorizálva Drawmer
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025