Használati útmutató Blaze B800
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Blaze B800 (8 oldal) a Fűtő kategóriában. Ezt az útmutatót 9 ember találta hasznosnak és 5 felhasználó értékelte átlagosan 4.9 csillagra
Oldal 1/8

Revision B
Installaon Instrucons
Contemporary and Stylish
Keep instrucons for future reference
Glen Dimplex Australia proudly supports the acvies of Landcare Australia through its membership of the AHHA
B500
B800

CONTENTS
1. INSTALLATION ................................................................... 1
1.1. IMPORTANT INFORMATION .................................... 1
1.2. INSTALLING THE HEATER ......................................... 2
1.2.1. Posioning the Heater 2 ........................................
1.2.2. Standard Installaon ........................................... 2
1.2.3. Corner Installaon 2 ..............................................
1.2.4. Floor Protector .................................................... 2
1.3. REDUCING CLEARANCES TO COMBUSTIBLES .......... 3
1.4. INSTALLING THE FLUE .............................................. 3
1.5. INSTALLING THE BAFFLE PLATE ............................... 4
1.6. INSTALLING THE FIRE BRICKS 5 ..................................
1.7. TECHNICAL DRAWINGS 6 ...........................................
1. INSTALLATION
1.1. IMPORTANT INFORMATION
The unit must be installed according to all manufacturers’
instrucons included in manual. The manufacturer is not this
liable for installaons that do not meet the requirements
outlined in this manual.
Most building regulatory authories in Australia require any
wood heater installaon to comply with Installaon Standard
AS/NZS 2918. Dierent states and councils may have varying
regulaons. Check local building regulaons before installing
the appliance.
All Blaze wood heaters have been tested to ensure they will
meet the appropriate safety standard requirements if the
instrucons in this manual are followed. As the safety and
emissions performance can be aected by altering the
appliance, no modicaons are allowed without wrien
permission from the manufacturer.
WE RECOMMEND THAT THE INSTALLATION OF YOUR BLAZE
WOOD HEATER BE CARRIED OUT BY A QUALIFIED INSTALLER.
WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE
INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE
APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING
CODE OR CODES.
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH
THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS
OF AS/NZS 4012 & AS/NZS 4013 WHERE REQUIRED BY THE
REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE
IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING
‘TESTED TO AS/NZS 4012 & AS/NZS 4013’.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED
FOR COMPLIANCE WITH AS/NZS 4012 & AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM
COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS
CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED
IN THE FIRST INSTANCE.
CAUTION: CRACKED AND BROKEN COMPONENTS, EG. GLASS
PANELS OR CERAMIC TILES, MAY RENDER THE INSTALLATION
UNSAFE.
THE INSTALLATION INSTRUCTIONS IN THIS MANUAL
APPLY TO THE BLAZE B50 AND B80 FREE-STANDING 0 0
WOOD HEATER MODELS.
THEY HAVE BEEN TESTED FOR EMISSIONS AND
EFFICIENCY AND COMPLY ACCORDING TO AS/NZS 4012 &
AS/NZS 4013.

1.2. INSTALLING THE HEATER
1.2.1. Posioning the Heater
Review the necessary clearances specied in this secon
before considering where to posion the heater.
Also check the praccability of installing the ue system in
relaon to any obstrucng roof beams before posioning the
heater.
The clearance distances can only be reduced if the
surrounding walls are made of non-combusble material such
as stone, brick or concrete. If non-combusble material,
distance can be reduced to 100 mm. Alternavely, shielding of
the wall(s) can reduce clearances (refer to next secon for
more detail).
Clearances to combusble surfaces vary depending on the
type of ue shielding used, and if oponal side shields have
been added to the heater.
1.2.2. Standard Installaon
Dimensions given in the table and image below represent the
minimum clearance (in millimetres) to combusble materials.
A = Minimum oor protector width
B = Minimum oor protector depth from door opening
X = Rear clearance
Y = Side clearance
Dimensions (mm)
Model
X
Y
A
B
B500
125
350
900
300
B800
125
300
1000
400
1.2.3. Corner Installaon
Dimensions given in the table and image below represent the
minimum clearance (in millimetres) to combusble materials.
A = Minimum oor protector width
B = Minimum oor protector depth from door opening
Z = Corner clearance
Dimensions (mm)
Model
Z
A
B
B500
100
900
300
B800
100
1000
400
1.2.4. Floor Protector
Unless the heater will be standing on a heat resistant oor
such as concrete slab with slate or les, it will be necessary to
provide a oor protector.
The minimum required dimensions for the oor protector are
shown in the previous secons. It may be desirable, for
example aesthec reasons, for the oor protector to be larger
than these minimum dimensions.
The oor protector shall be constructed of non-combusble
material no less than 15mm thick and with a thermal
conducvity not greater than 0.33W/m °K, eg. compressed
cement sheet.
The oor protector may be laid directly on the combusble
oor.
For more details and variaons on oor protectors refer to
AS/NZS 2918 Clause 2.2, 3.3.1, & 3.3.2.
Termékspecifikációk
Márka: | Blaze |
Kategória: | Fűtő |
Modell: | B800 |
Szüksége van segítségre?
Ha segítségre van szüksége Blaze B800, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Fűtő Blaze
19 Augusztus 2024
17 Augusztus 2024
13 Augusztus 2024
11 Augusztus 2024
10 Augusztus 2024
9 Augusztus 2024
5 Augusztus 2024
4 Augusztus 2024
4 Augusztus 2024
4 Augusztus 2024
Útmutatók Fűtő
- Fűtő Beper
- Fűtő Arlec
- Fűtő Sun Joe
- Fűtő Milwaukee
- Fűtő Nevir
- Fűtő Excelair
- Fűtő Grandhall
- Fűtő Supra
- Fűtő Unold
- Fűtő Bomann
- Fűtő Xiaomi
- Fűtő Nestor Martin
- Fűtő Corbero
- Fűtő Heat Storm
- Fűtő Uniprodo
Legújabb útmutatók Fűtő
6 Április 2025
4 Április 2025
30 Március 2025
30 Március 2025
30 Március 2025
30 Március 2025
27 Március 2025
27 Március 2025
27 Március 2025
27 Március 2025