RANGE HOOD CORD KIT
Installation Instructions
WARNING
CORD KIT INSTALLATION
1. Remove this
electrical knockout
only.
2. Use bushing to
connect plate to
BUSHING
PLATE
CORD
CONNECTOR
3. Align plate with
knockout and attach
cord connector to
BLACK
WIRES
WHITE
WIRES
GREEN
GROUND WIRE
GROUND
SCREW*
4. Connect black wires together. Connect togeth-white wires
er. Connect green ground wireground screw beneath .
*If the range hood has an internal ground connection beneath
a ground screw, A SECOND GROUND SCREW MUST BE
USED for the cord kit ground.
99523894J
CAUTION
TO REDUCE THE RISK OF FIRE AND ELECTRICAL SHOCK,
THIS RANGE HOOD CORD-CONNECTION KIT IS U.L. CLAS-
SIFIED ONLY FOR USE WITH THE RANGE HOOD MODEL
SERIES LISTED BELOW:
BROAN SERIES
40000, 41000, 42000,
43000, 46000, 52000,
53000, 88000, 89000,
AP1, APE, B30, CBD1,
CBD3, CBX1, CJD1,
CJD3, E661, QDE,
QL1, QML, QP1, QP2,
QP3, QP4, QS1, QS2,
QS3, QSE, QT20000,
RP1, RP2
NUTONE SERIES
RL, SL, WA65,
WS1, WS2, WS3,
NSP1, NS65
KENMORE SERIES
5094, 5104, 5114, 5134, 5154, 5164, 5174, 5184,
5204, 5205, 5214, 5215, 5234, 5244, 5254,
5260, 5261, 5270, 5271, 5324, 5334, 5501,
5502, 5511, 5512, 5521, 5522, 5535, 5580,
5817, 5818
ELECTRICAL RECEPTACLE LOCATION
A grounded, electrical receptacle for this cord kit must be in a
location that will not allow the cord to come in contact with any
heat source. Inside the cabinet above the range is the most com-
mon location.
Do not plug into receptacles that would permit cord to come
into contact with heat sources.
FOR USE WITH RANGE HOODS ONLY.
GROUNDING INSTRUCTIONS
Range Hoods must be grounded. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by providing
an escape wire for the electric current. After attaching this cord
kit to the range hood, it is equipped with a cord having a ground-
ing wire with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded.
WARNING - Improper grounding can result in a risk of electric
shock.
Consult a qualified electrician if the grounding instructions are not
completely understood, or if doubt exists as to whether the range
hood is properly grounded.
Do not use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the appliance.
This kit includes the following:
(1) 36” Cord & Plug with Cord Connector
(1) Anti-Rotation Plate with Lock Bushing
(2) Wire Nuts
WIRING CONNECTIONS
Other cord kits are not U.L. Classified - unless the specific
model numbers are listed.

Értékelje ezt az útmutatót

4.6/5 (7 Vélemények)

Termékspecifikációk

Márka: Broan
Kategória: légvezető búra
Modell: ALT230WW

Szüksége van segítségre?

Ha segítségre van szüksége Broan ALT230WW, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók légvezető búra Broan

Útmutatók légvezető búra

Legújabb útmutatók légvezető búra

Smeg
Smeg

Smeg KD6XE Útmutató

22 Június 2024
Smeg

Smeg KDD90CNE Útmutató

22 Június 2024
Smeg
Smeg

Smeg KD61XE2 Útmutató

22 Június 2024
Smeg

Smeg KDC61XE2 Útmutató

22 Június 2024
Smeg

Smeg KICGR52X Útmutató

22 Június 2024
Smeg

Smeg KL175XE Útmutató

22 Június 2024
Smeg

Smeg KICV90BL Útmutató

22 Június 2024