PROPANE (LP) CONVERSION INSTRUCTIONS
31-11086 Rev. 2 06-19 GEA
CGS750M, CGS995, add CGS750P
BURNER OUTPUT RATINGS: BTU/HR
Propane (LP) Gas 10” W.C.P.
BURNER
BTU
RATE
ORIFICE
LF18,000
LF1N/A0.027None69L
LF2N/A0.027None69L
LF3N/A0.027None69L
LFCN/A0.016None40L
LR5,0000.026Red/Yellow66L
CF9,5000.0365Orange/Light Blue92L
CR9,5000.0365Orange/Light Blue92L
RF15,0000.045Orange/Silver114L
RR12,0000.039Blue/Magenta99L
Upper Bake7,0000.031Brown031L
Broil13,5000.042Grey042L
Lower Bake13,5000.043Green043L
To adjust your range for use with propane (LP) gas, follow
these instructions:
1. Disconnect all electrical power, at the main circuit breaker or
fuse box.
6KXWRႇWKHJDVVXSSO\WRWKHUDQJHE\FORVLQJWKHPDQXDO
VKXWRႇYDOYH
CONVERTING THE PRESSURE REGULATOR
CONVERTING THE COOKTOP BURNERS
A. Remove the top grates, burner caps and burner heads.
B. Using a 7 mm or 9/32” nut driver, remove the top burner
RUL¿FHV7KHVHPD\EHDFFHVVHGWKURXJKWKHEXUQHU
opening in the base.
&5HPRYHWKHSURSDQH/3RUL¿FHVIURPWKHER[SURYLGHG
7KHSURSDQH/3RUL¿FHVKDYHWKHOHWWHU³/´RQWKHWRS
To aid in identifying the proper location for the propane (LP)
RUL¿FHVGXULQJFRQYHUVLRQIURP1DWXUDO*DVWR3URSDQH/3
Gas, color codes have been added to the side or top of the
RUL¿FH6HHWKHFKDUWEHORZ(DFKRUL¿FHPD\DOVRVKRZD
series of engraved marks (I, II, III . . .) located on the top.
1. Use an adjustable wrench to unscrew the hex-nut cap from
the pressure regulator.
&RPSOHWHO\UHPRYHWKHSURWHFWLYHSODVWLFFDSRႇWKH
threaded metal cap.
3. Turn the metal cap so the type of gas being converted to is
displayed and replace the protective plastic cover.
4. Screw the hex-nut cap back into the regulator.
(Do not over tighten)
TOOLS REQUIRED:
Adjustable wrench
Socket wrench with
1/2” socket and extension
Phillips head screwdriver
Flat bladed screwdriver
(blade approximately
3/32” across)
Nut drivers: 1/4”, 9/32”
or 7mm
PROPANE (LP) CONVERSION INSTRUCTIONS
PROPANE
NAT
Rotate cap counter-
clockwise to loosen
Cap assembly
NOTICE:
6DYHWKHVHRUL¿FHVIRUIXWXUHFRQYHUVLRQEDFNWRQDWXUDOJDV
WARNING
Do not operate the cooktop or oven
burners of this range when using propane (LP) (bottled) gas
EHIRUHFRQYHUWLQJWKHSUHVVXUHUHJXODWRUDQGEXUQHURUL¿FHV
for propane (LP) gas use. Failure to do so could cause high
ÀDPHVDQGWR[LFIXPHVZKLFKFDQUHVXOWLQVHULRXVLQMXU\
7KHSUHVVXUHUHJXODWRUDQGWKHEXUQHURUL¿FHVDUHVHWIRU
natural gas. To use propane (LP) gas, the regulator and burner
RUL¿FHVPXVWEHFRQYHUWHG
7KHSURSDQH/3RUL¿FHVIRUWKHFRRNWRSEXUQHUVDUHVKLSSHG
on the back of the range in the location shown.
',QVWDOOWKHSURSDQH/3RUL¿FHVLQWKHLUSUHFLVHORFDWLRQV
7RSUHYHQWOHDNDJHPDNHVXUHWKHRUL¿FHVSXGVDUHVHFXUHO\
screwed into the gas supply tubes.
(,QVWDOOWKHROGRUL¿FHVSXGVLQWRWKHPHWDOER[RUEUDFNHW
along with these instructions, and replace onto the back of the
range for possible future conversion.
LR
LF2LF1
LFC
LF3
LF
RR
RF
CR
CF
Propane
Red/Yellow
Propane
Blue/Magenta
Propane
Orange/Light Blue
Propane
None
Propane
None
Propane
None
Propane
None
Propane
Orange/Silver
Propane
Orange/Light Blue
Multi-ringRound burner
Burner cap
Burner cap
Burner cap
Burner head
Burner head
Base
Base
2UL¿FHORFDWHG
through this
opening
Pressure
Regulator
Location
Rear of Range
Propane (LP)
Conversion Kit
CHECK SURFACE BURNERS
3XVKDQGWXUQDNQREWRWKH/,7(SRVLWLRQ$FOLFNLQJVRXQG
indicates proper operation of the ignition system. When lighting
DQ\EXUQHUVSDUNVZLOODSSHDUDWDOOEXUQHUVEXWJDVÀRZV
from only the one selected. Once air is purged from the supply
line, burner should light within 4 seconds. After burner lights,
URWDWHWKHNQRERXWRIWKH/,7(SRVLWLRQ7U\HDFKEXUQHULQ
succession until all burners have been checked.
Quality of Flames
'HWHUPLQHWKHTXDOLW\RIÀDPHVYLVXDOO\1RUPDOEXUQHUÀDPHV
should look like (A) or (B).
/RQJEULJKW\HOORZÀDPHVDUHQRWQRUPDO1RUPDOÀDPHVPD\
show signs of an orange tint when well heated or signs of
ÀLFNHULQJRUDQJHGXHWRSDUWLFOHVLQWKHJDVRUDLU
95
III
Denotes 0.95mm Orifice size opening
Denotes LP (Propane)
WARNING
Explosion Hazard
Death or serious injury can result from failure to follow
these instructions.
Service by a qualified service technician only.
Shut off gas supply and disconnect power before servicing.
Reconnect all grounding devices after service.
Replace all parts and panels before operating.
(A) Soft blue flames—
Normal for natural gas
(B) Yellow tips on
outer cones—
Normal for propane (LP) gas