Használati útmutató Cocraft DL-04

Oldalak 4 Angol nincs kategorizálva

Olvassa el ingyen online a(z) Cocraft DL-04 használati útmutatóját, vagy töltse le PDF-ben. Az útmutatót 24 alkalommal tekintették meg. Kérdése van a modellről? Tegyen fel kérdést

GREAT BRITAIN
For consumer contact, please visit www.clasohlson.co.uk
and click on customer service.
Digital Spirit Level
Art. No 40-8180 Model DL-04 (D600XP)
Please read theentire instruction manual before use and save it for future
reference. Wereserve theright for any errors in text or images and for making any
necessary technical changes to this document. Ifyou should have any questions
concerning technical problems please contact our Customer Services.
Safety
• Always keep thespirit level out of thereach of children and animals.
• Remove exhausted batteries.
• Do not incinerate exhausted batteries.
• Do not short-circuit thebatteries.
• Do not mix old and new batteries.
• Make sure that thebatteries are inserted as indicated by themarkings in
thebattery compartment.
Care and maintenance
The spirit level is aprecision instrument and must be handled with care.
Do not expose thespirit level to dust and moisture. The spirit level must not
be subjected to blows, vibration and extreme temperatures. If thespirit level
is to be unused for along time, remove thebatteries.
Disposal
Follow local ordinances when disposing of this product. If you are unsure
about how to dispose of this product contact local council.
Description
• 600 mm digital spirit level.
• Sturdy aluminium frame.
• Two bubble vials for level and plumb, high precision, deviation only ± 0.5 mm/m.
• Digital slope measurement, accuracy ± 0.2°. Resultcan be displayed in °,
%, mm/m or in/ft.
• V-shaped groove along theentire underside allows precision measurement
on pipes as well.
If you choose theunits in/ft, thedisplay
shows H = 6 7/8” (H=L·tan α, L = 3.28 ft,
α = 30°). If you choose slope in %,
thedisplay shows H = 57.72 (H=L·tan , α
L = 100, α= 30°).
Buttons
1. [CAL] Press to enter calibration mode.
2. [UNIT] ] Press to toggle between different display units: ° (degrees),
% (slope), mm/m and in/ft (rising - falling).
3. [Hold] Press to save thecurrently displayed data. Whenthe hold function
has been activated, thedisplay shows H”. Press[Hold] again to deac-“
tivate thefunction.
4. [REF] Press to save areference point. Whenthe reference point has been
saved, thedisplay shows S”. Press[REF] again to deactivate it.“
5. [Audio] Switch buzzer on/off. Whenthe buzzer is on, it sounds at 0°, 45°
and 90° (± 0.5°).
6. [] Press to switch on thespirit level. Holddown for about three seconds
to switch off thespirit level.
Display icons
7. Showsgraphically whether thelevel is sloping up or down or is level.
8. Showsthat thebuzzer is active
9. Hshows that thehold function has been activated (display data frozen)
10. Sshows that areference point has been saved
11. Showsthe slope
12. Batterystatus
Examples of different displays for thesame slope. Press[UNIT] to change
thedisplay units.
Measuredslope is
displayed in
degrees: 30°
Measuredslope
is displayed as
apercentage:
57,72 %
Measuredslope is
displayed in
millimetres/metre:
577 mm/m
Measuredslope
is displayed in
inches per foot:
6 7/8 in/ft
Ifthe angle is greater than 45° but less
than 90° (H=L/tan ).α
NOTE: The display switches off automatically when thebatteries are low.
Tosave thebatteries there is an automatic switch-off function which switches
off thespirit level if it has been motionless for three minutes.
Use
1. Press []; thedisplay comes on.
2. Placethe spirit level on alevel surface. Theslope is displayed directly as 0–90°.
3. Theangle is displayed in both directions.
Measurement from a reference surface
During measurement you can save ameasured
value as 0° so that it can be used as areference
for thenext measurement.
Example: You want to use theslope (A) as
areference for thenext measurement (B).
1. Place thespirit level on thereference surface (A).
2. Press [REF]. Thedisplay shows 0”.“
3. Place thespirit level on thenew measurement
surface (B).
4. Read off theangle between (A) and (B) on
thedisplay.
Calibrating the spirit level
1. Placethe spirit level on aat surface with aslope of less than 5°.
Ifthe slope is greater, thedisplay shows “Err”.
2. Holddown [CAL] for about ve seconds to start calibration.
3. Whenthe display shows “CAL 1”, release thebutton and wait for
theactual slope to be displayed.
4. Turnthe spirit level through 180° and put it back on thesame surface.
5. Holddown [CAL] for about ve seconds and release thebutton when
“CAL 2” appears.
6. “CAL 2” ashes three times and thereading is displayed again.
Technical specification
Length600 mm
Accuracy, digital slope gauge± 0.2°
Accuracy of bubble vials± 0.5 mm/m
Measuring range0 to 90°
Units of measurement°, %, mm/m, in/ft
Environment for use0 °C to 40 °C
1
3
9
8 10 12
52
711
4
6
H=L·tan α
H=L/tan α
45°<< 90°α

Értékelje ezt az útmutatót

Termékspecifikációk

Márka: Cocraft
Kategória: nincs kategorizálva
Modell: DL-04

Szüksége van segítségre?

Ha segítségre van szüksége Cocraft DL-04, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek