WATER COOLED OIL FREE CENTRIFUGAL CHILLERS
Operating Manual
D-EOMWC01405- 3 19_0 EN

D-EOMW - 3 - 2/ C01405 18_0 EN 52
TABLE OF CONTENTS
1 SAFETY CONSIDERATIONS ......................................................................................................................................... 5
1.1 General 5 ....................................................................................................................................................................
1.2 Before switching the unit ......................................................................................................................................... 5
1.3 Avoid electrocution .................................................................................................................................................. 5
2 GENERAL DESCRIPTION 6 .............................................................................................................................................
2.1 Basic Information .................................................................................................................................................... 6
2.2 Abbreviations used 6 ..................................................................................................................................................
2.3 Controller Operating Limits ..................................................................................................................................... 6
2.4 Controller Architecture ............................................................................................................................................ 6
2.5 Communication Modules 7 .........................................................................................................................................
3 USING THE CONTROLLER ........................................................................................................................................... 8
3.1 Navigating ............................................................................................................................................................... 9
3.2 Passwords ............................................................................................................................................................... 9
3.3 Editing ................................................................................................................................................................... 10
3.4 Basic Control System Diagnostic .......................................................................................................................... 10
3.5 Controller maintenance ......................................................................................................................................... 11
3.6 Optional Remote User Interface ........................................................................................................................... 11
3.7 Embedded Web Interface ..................................................................................................................................... 11
4 MENU STRUCTURE ..................................................................................................................................................... 13
4.1 Main Menu ............................................................................................................................................................ 13
4.2 View/Set Unit ......................................................................................................................................................... 13
Thermostat Ctrl ............................................................................................................................................. 13
Network Ctrl .................................................................................................................................................. 14
Pumps ........................................................................................................................................................... 14
Condenser .................................................................................................................................................... 14
Evaporator .................................................................................................................................................... 15
Master/Slave ................................................................................................................................................. 15
4.2.6.1 Data ...................................................................................................................................................... 15
4.2.6.2 Options ................................................................................................................................................. 16
4.2.6.3 Thermostat Ctrl .................................................................................................................................... 16
4.2.6.4 Timers .................................................................................................................................................. 16
4.2.6.5 Standby Chiller ..................................................................................................................................... 16
Rapid Restart ................................................................................................................................................ 17
Date/Time ..................................................................................................................................................... 17
Scheduler ...................................................................................................................................................... 17
Power Conservation ..................................................................................................................................... 17
Controller IP setup ........................................................................................................................................ 18
Daikin on Site ............................................................................................................................................... 18
Software Options .......................................................................................................................................... 19
4.2.13.1 Changing the Password for buying new Software Options . ................................................................ 19
4.2.13.2 Inserting the Password in a Spare Controller ...................................................................................... 19
4.2.13.3 Modbus MSTP Software Option .......................................................................................................... 21
4.2.13.4 BACNET MSTP ................................................................................................................................... 22
4.2.13.5 BACNET IP .......................................................................................................................................... 23
Menu Password ............................................................................................................................................ 23
4.3 Active Setpoint ...................................................................................................................................................... 24
4.4 Evaporator LWT .................................................................................................................................................... 24
4.5 Condenser LWT .................................................................................................................................................... 24
4.6 Unit Capacity ......................................................................................................................................................... 24
4.7 Unit Mode .............................................................................................................................................................. 24
4.8 Unit Enable ............................................................................................................................................................ 25
4.9 Timers ................................................................................................................................................................... 25
4.10 Alarms ................................................................................................................................................................... 25

D-EOMW - 3 - 3/ C01405 18_0 EN 52
4.11 Commission Unit ................................................................................................................................................... 25
Alarm Limits .................................................................................................................................................. 25
Calibrate Sensors ......................................................................................................................................... 26
4.11.2.1 Unit Calibrate Sensors ......................................................................................................................... 26
4.11.2.2 Compressor Calibrate Sensors ............................................................................................................ 26
Scheduled Maintenance ............................................................................................................................... 26
4.12 About this Chiller ................................................................................................................................................... 26
5 WORKING WITH THIS UNIT ........................................................................................................................................ 27
5.1 Unit Setup ............................................................................................................................................................. 27
Control Source .............................................................................................................................................. 27
Available Mode Setting ................................................................................................................................. 27
It has to be noted that in case the selected mode cannot be managed by the unit, it will revert to Cool. ................. 28
Temperature Settings ................................................................................................................................... 28
5.1.3.1 LWT Setpoint Setting ........................................................................................................................... 28
5.1.3.2 Thermostat Control Settings ................................................................................................................ 28
5.1.3.3 Pumps .................................................................................................................................................. 29
Power Conservation ..................................................................................................................................... 29
5.1.4.1 Demand Limit ....................................................................................................................................... 29
5.1.4.2 Current Limit (Optional) ........................................................................................................................ 30
5.1.4.3 Setpoint Reset ..................................................................................................................................... 30
5.1.4.4 Setpoint Reset by External 4-20 mA Signal ......................................................................................... 30
5.1.4.5 Setpoint Reset by Evaporator Return Temperature ............................................................................ 30
5.1.4.6 Soft Load .............................................................................................................................................. 31
Date/Time ..................................................................................................................................................... 31
5.1.5.1 Date,Time and UTC Settings ............................................................................................................... 31
Scheduler ...................................................................................................................................................... 31
5.2 Unit Start- up .......................................................................................................................................................... 31
Unit Status .................................................................................................................................................... 31
Prepare the unit to start ................................................................................................................................ 32
5.2.2.1 Unit Switch Enable ............................................................................................................................... 32
Keypad Enable ............................................................................................................................................. 32
5.2.3.1 BMS Enable ......................................................................................................................................... 32
5.3 Condensation Control ........................................................................................................................................... 33
6 ALARMS AND TROUBLESHOOTING ......................................................................................................................... 34
6.1 Unit Alerts .............................................................................................................................................................. 34
Bad Demand Limit Input ............................................................................................................................... 34
Bad Leaving Water Temperature Reset Input .............................................................................................. 34
Condenser Pump #1 Failure (W/C units only) .............................................................................................. 34
Condenser Pump #2 Failure (W/C units only) .............................................................................................. 35
Evaporator Pump #1 Failure ......................................................................................................................... 35
Evaporator Pump #2 Failure ......................................................................................................................... 35
External Event .............................................................................................................................................. 36
Password Over Time .................................................................................................................................... 36
6.2 Unit Pumpdown Stop Alarms ................................................................................................................................ 36
Condenser Entering Water Temperature (EWT) sensor fault ...................................................................... 36
Condenser Leaving Water Temperature (LWT) sensor fault ....................................................................... 36
Evaporator Entering Water Temperature (EWT) sensor fault ...................................................................... 37
Evaporator Water Temperatures inverted .................................................................................................... 37
Liquid Temperature Sensor fault .................................................................................................................. 37
6.3 Unit Rapid Stop Alarms ......................................................................................................................................... 38
PVM alarm (A/C units only) .......................................................................................................................... 38
Condenser Water Freeze alarm (W/C units only) ........................................................................................ 38
Condenser Water Flow Loss alarm (W/C units only) ................................................................................... 38
Emergency Stop ........................................................................................................................................... 39
Evaporator Flow Loss alarm ......................................................................................................................... 39
Evaporator Leaving Water Temperature (LWT) sensor fault ....................................................................... 39
Termékspecifikációk
Márka: | Daikin |
Kategória: | légkondicionáló |
Modell: | EWWSC14DZXSA2 |
Szüksége van segítségre?
Ha segítségre van szüksége Daikin EWWSC14DZXSA2, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók légkondicionáló Daikin
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
30 Március 2025
16 Január 2025
16 Január 2025
10 Január 2025
10 Január 2025
Útmutatók légkondicionáló
- légkondicionáló Vaillant
- légkondicionáló SPT
- légkondicionáló Duracraft
- légkondicionáló Guzzanti
- légkondicionáló Be Cool
- légkondicionáló Coolix
- légkondicionáló Aermec
- légkondicionáló Handson
- légkondicionáló InAlto
- légkondicionáló Friedrich
- légkondicionáló Suntec
- légkondicionáló Sauber
- légkondicionáló Anslut
- légkondicionáló Blaupunkt
- légkondicionáló Columbia Vac
Legújabb útmutatók légkondicionáló
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025