INSTRUCTIONS
1. To determine if the Strike Shim positions need adjustment, measure dimension “R” (see Figure 1) from the center to the edge
of the latch. When necessary rearrange Strike Shims according to the chart below. The “shipped as default” positions are
illustrated in Figure 2.
SHIM PLACEMENT CHART
Note: Shims consist of two thin and one thick. Install with the indicated hardware per the appropriate measurement R range.
Fig. 1
I N S T A L L A T I O N
© 2015 RutheRfoRd ContRols Int’l | A doRMA GRoup CoMpAny
www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com
When installing an electric strike on an inactive door of a set of double doors, it can be treated the same as a frame installation in most situations. For
more information contact the Technical Service Department at 1-800-265-6630 or 519-621-7651.
Fire labeled heavy-duty electric strike
F1114
isf1114 Pcn14079
r06/15Gr
Fig. 2
Measurement “R” “S1” Shims “S1” Screws “S2” Shims “S2” Screws
5/16” (8.2mm) or Less None M4 x 10mm 1 thick, 2 thin M4 x 10mm
5/16” - 3/8”, (8.2 - 9.7mm) 1 thin M4 x 10mm 1 thick, 1 thin M4 x 10mm
3/8” - 7/16”, (9.7 - 10.7mm) 1 thick M4 x 10mm 2 thin M4 x 10mm
7/16” - 1/2”, (10.7 - 12.2mm) 1 thick, 1 thin M4 x 14mm 1 thin M4 x 10mm
1/2” - 9/16” (12.2 - 13.7mm) 1 thick, 2 thin M4 x 14mm none none
S1 S2
Shipped as Default
“R” distance
from center to
edge of latch
“R” distance from
center to edge of latch
Deadlock
Trigger
Deadlock
Trigger
Mortise Lock Cylindrical Lock

2. Determine the horizontal centerline.
FOR MORTISE LOCKS: Position the strike against the edge
of the door with the deadlock trigger fully on the strike’s
angled ramp and the latch within the strike cavity. Move
door close to the frame. The horizontal centerline is clearly
molded into the strike’s pry-guard. Transfer onto door frame.
FOR CYLINDRICAL LOCKS: Simply align the center of the
latch with the center of the strike cavity. Move door close
to the frame. The horizontal centerline is clearly molded
into the strike’s pry-guard. Transfer onto door frame.
3. Determine the vertical centerline of the door lock face,
carefully considering any stops or gasket and transfer onto
the door frame.
4. Use the vertical and horizontal centerlines marked on the
drawing below to prepare the door frame for cutting.
5. If required, install the optional “no weld” mounting
tabs.
6. Connect the incoming wiring from the power supply to
the terminal screws on the strike insert. RCI door strikes
are not polarity sensitive although be certain to observe
proper polarity if a suppression diode is required for access
control applications. To meet BHMA A156.31 install the
MOV provided across the red & black power wires.
7.
Install the door strike in the door frame using the screws provided.
8. See Installation Tips on page 3.
I N S T A L L A T I O N
Fire labeled heavy-duty electric strike
F1114
© 2015 RutheRfoRd ContRols Int’l | A doRMA GRoup CoMpAny
www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com
INSTRUCTIONS Cont’d.
In or Out... we make it Easy!®
NOTE: Specifications subject to change without notice.
* Dimension F is measured from face of mounting tab to face of frame.
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
A 1-1/4” 1.25 31.8
/B 4-7 8” 4.87 123.8
C 3-3/8” 3.38 85.7
D 1-1/2” 1.50 38.1
/E 3 8” 0.38 9.5
/F 1 8” 0.13 3.2
G 1-11/16” 1.69 42.9
X
4-1/K 8” 4.13 104.8
M 12-24 N/A N/A
F1114
Vertical Centre Line of Door
Lock and Mounting Face Plate
Fig. 3
2

I N S T A L L A T I O N
Fire labeled heavy-duty electric strike
F1114
© 2015 RutheRfoRd ContRols Int’l | A doRMA GRoup CoMpAny
www.rutherfordcontrols.com • Phone: 1.800.265.6630 • fax: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com
In or Out... we make it Easy!®
These photos show three simple steps to a quick and easy strike insertion.
iNstallatiON seQueNce tiPs
Frame Preparation:
Should the frame not be cut out
for the F1114, follow the directions
located in Fig 3 on Page 2.
Initial Position:
Place the strike as shown with the
mounting tab located between the
face plate and the insert.
STEP 1
Strike Position:
Rotate the strike into the frame.
Note that the strike is angled
slightly forward to clear the Pry-
Guard.
STEP 2
Final Push:
Push the strike into the frame. The
pry-guard should be behind the
front lip of the frame.
STEP 3
Ready to Secure:
The strike is now in position ready
to be secured by the two (2) 12-24
mounting screws.
3
Termékspecifikációk
Márka: | Dormakaba |
Kategória: | nincs kategorizálva |
Modell: | RCI F1114 |
Szüksége van segítségre?
Ha segítségre van szüksége Dormakaba RCI F1114, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva Dormakaba
19 Augusztus 2024
19 Augusztus 2024
19 Augusztus 2024
19 Augusztus 2024
19 Augusztus 2024
19 Augusztus 2024
19 Augusztus 2024
19 Augusztus 2024
19 Augusztus 2024
19 Augusztus 2024
Útmutatók nincs kategorizálva
- nincs kategorizálva Eve Audio
- nincs kategorizálva Emilia
- nincs kategorizálva Integral LED
- nincs kategorizálva CyberPower
- nincs kategorizálva Medisana
- nincs kategorizálva C2G
- nincs kategorizálva Spektrum
- nincs kategorizálva Qute
- nincs kategorizálva AOC
- nincs kategorizálva Standard Horizon
- nincs kategorizálva Ocean Matrix
- nincs kategorizálva Brigmton
- nincs kategorizálva Fulltone
- nincs kategorizálva Vonroc
- nincs kategorizálva Playmobil
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025