Használati útmutató Emos MD-210
Emos
multiméter
MD-210
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Emos MD-210 (56 oldal) a multiméter kategóriában. Ezt az útmutatót 4 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra
Oldal 1/56

2202007000_31-M0391_00_01 115 × 165 mm
www.emos.eu
M0391 | MD-210
GB Digital Multimeter
CZ Digitální multimetr
SK Digitálny multimeter
PL Multimetr cyfrowy
HU Digitális multiméter
SI Digitalni multimeter
RS|HR|BA|ME Digitalni multimetar
DE Digitales Multimeter
UA Цифровий мультиметр
RO Multimetru digital
LT Skaitmeninis multimetras
LV Digitālais multimetrs
EE Digitaalne multimeeter
BG Цифров мултиметър

2
1
300
300
300
300
300
EVERY
1
2
35
4
GB | Digital Multimeter
Before you begin using multimeter MD-210, read
this instruction manual thoroughly. It contains
particularly important passages concerning occupa-
tional safety principles when using the device. Such
passages are highlighted. Reading the manual will
prevent potential injury by electric current or damage
to the device.
The multimeter was designed in accordance with the
IEC-61010 standard regarding electronic measuring
devices in the category (CAT III 300 V), for 2nd pol-
lution degree.
Category CAT III is designed for measuring circuits
powered by a xed output power supply, such as relays,
sockets, switchboards, power supplies, short branching
circuits and lighting systems in large buildings.
alternating current (AC)
direct current (DC)
direct and alternating current (AC/DC)
earthing
double insulation
low battery
diode
fuse
warning
risk of injury by electric current
product complies with applicable EU standards
This symbol means: warning, risk of danger. Read
the manual in all cases where this symbol is used!
This symbol indicates risk of injury by electric
current.
ATTENTION
Comply with the following instructions in particular:
• Make sure the device is not damaged before you
begin using the multimeter. If you nd obvious
signs of damage on the body of the device, do not
make any measurements! Check that the surface of
the multimeter does not have scratches and that
the side joints are not coming apart.
• Do not measure voltage higher than 300 V, or
current higher than 10 A!
• The COM terminal must always be connected to
reference ground.
• Also check the measuring tips. Insulation on the
measuring probes should have no visible signs of
damage. Damaged insulation may result in injury
by electric current. Therefore, do not use damaged
measuring probes.
• If you nd that the multimeter is making abnormal
measurements, stop using it. These may be caused
by a disrupted fuse. If you are unsure of the cause
of the defect, contact a service centre.
• -Do not use or store the multimeter in environ
ments with high temperature, dust or humidity.
It is also not recommended to use the device in
environments with potentially strong magnetic
elds or risk of explosion or re.

3
• Do not measure voltages and currents higher than
indicated on the front panel of the multimeter.
Risk of injury by electric current or damage to
the multimeter!
• Check that the multimeter is working properly
before use. Test on a circuit with known electrical
values.
• Before you connect the multimeter to a circuit you
intend to measure, turn o the power to the circuit.
• -If you need to replace a component of the mul
timeter (e.g. battery, fuse), always use spare parts
of the same type and specifications. Change
parts only when the multimeter is disconnected
and turned o.
• Do not alter or otherwise interfere with the internal
circuitry of the multimeter!
• Be extra careful when measuring voltages higher
than 30 V AC rms, 42 V peak or 60 V DC. Risk of
injury by electric current!
• When using measuring tips, make sure you are
holding them behind the nger barriers.
• -Disconnect the measuring tips from the tested cir
cuit before opening the casing of the multimeter.
• Do not perform measurements if the multimeter‘s
casing is removed or loose.
• Change the battery once the low battery warning
indicator appears on the screen. Otherwise,
subsequent measurements may be inaccurate.
Incorrect measurements may then result in injuries
by electric current!
ATTENTION
Use multimeter MD-210 only in the manner specied
below. Otherwise, the device could get damaged or
the user may suer injury. Comply with the following
instructions:
Before measuring resistance, diodes or current, discon-
nect the circuits from the power supply and discharge
the high-voltage capacitors.
Before measuring, make sure the circular switch for
measuring range is in the correct position. Under no
circumstances should you make any changes to the
measuring range (by moving the circular switch for
measuring programs) while measuring. Doing so could
damage the device.
If you intend to measure current, check the multimeter‘s
fuse and turn o the power supply to the circuit before
you connect the multimeter.
When you are measuring, rst connect the black con-
ductor (probe) and then the red conductor (probe).
When disconnecting the testing conductors, discon-
nect the red one rst.
Maintenance Instructions
Attention
Do not attempt to repair or modify the multimeter in
any way if you are not qualied for the task or do not
have access to the necessary calibration equipment.
To prevent injury by electric current, make sure that
water does not enter the inside of the multimeter!
• -Disconnect the measuring tips from the tested cir
cuit before opening the casing of the multimeter.
• Regularly clean the body of the multimeter with a
moist cloth and a mild detergent. Perform cleaning
only when the multimeter is disconnected and
turned o.
• Do not use solvents or abrasive agents for cleaning!
• If you are not using the multimeter for an extended
period of time, turn it o and remove the batteries.
• Do not store the multimeter in places with high
humidity and temperature or in places with a
strong magnetic eld!
Device Description
Multimeter MD-210 is a compact device with a 3.5
digit display. It is designed for measuring direct and
alternating voltage, direct and alternating current,
resistance, temperature, test diodes and perform audio
testing of conductivity and of circuits. The multimeter
provides protection against overload and informs the
user when the battery is low. It is ideal for use in e.g.
workshops, laboratories and households.
Front View of the Multimeter
1 – Screen – displays 3.5 digits i.e. a maximum value
of 1999
2 – Function and range switch – allows selecting
functions and the desired range as well as turning
the multimeter on or o. If you are not using the
multimeter, turn it o. The battery will then last
you longer.
3 – 10 A socket – used for connecting the plug of the red
(positive) tipped measuring conductor to measure
currents in 10 A DC current range.
4 – socket – used for connecting the plug of the red
(positive) tipped measuring conductor to measure
voltage, resistance or current to up to 200 mA.
5 – COM socket – used for connecting the plug of the
red (positive) tipped measuring conductor.
Specications
Screen: LCD, 1999 (3.5 digits) with automatic polarity
indication
Measuring method: dual-slope integration via an
A/D converter
Reading frequency: 2–3× per second
Operating temperature and humidity: 0°C to 40°C,
<75 %
Storage temperature and humidity: -10°C to 50°C,
relative humidity <85 %
Power supply: 1× 9 V (6F22) battery
Fuses: F 250 mA/300 V, ø 5×20 mm, F 10 A/300 V,
ø 5×20 mm
Low battery: indication via a battery symbol on the
screen
Indication of exceeded range: shows „OL“ on the LCD
Measuring category: CAT III (300 V)
Enclosure: IP20
Dimensions 28 × 138 × 70 mm
Weight: 141 g (battery included)
Termékspecifikációk
Márka: | Emos |
Kategória: | multiméter |
Modell: | MD-210 |
Szüksége van segítségre?
Ha segítségre van szüksége Emos MD-210, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók multiméter Emos

3 Szeptember 2024

2 Szeptember 2024

15 Augusztus 2024

8 Augusztus 2024

5 Augusztus 2024

4 Augusztus 2024

30 Július 2024

29 Július 2024

29 Július 2024

29 Július 2024
Útmutatók multiméter
- multiméter PeakTech
- multiméter Milwaukee
- multiméter Parkside
- multiméter Maxwell
- multiméter Voltcraft
- multiméter Vimar
- multiméter Digitus
- multiméter GW Instek
- multiméter Owon
- multiméter Aim TTi
- multiméter Gossen Metrawatt
- multiméter Amiko
- multiméter Klein Tools
- multiméter Chauvin Arnoux
- multiméter Workzone
- multiméter Beha-Amprobe
- multiméter Qian
- multiméter Joy-It
- multiméter Extech
- multiméter Gembird
- multiméter Testo
- multiméter Powerfix
- multiméter Biltema
- multiméter BaseTech
- multiméter REV
- multiméter BENNING
- multiméter Alecto
- multiméter Yato
- multiméter Velleman
- multiméter TFA
- multiméter Monacor
- multiméter Elro
- multiméter Fluke
- multiméter Uni-T
- multiméter Metrix
- multiméter Abus
- multiméter Megger
- multiméter Testboy
- multiméter Sonel
- multiméter Wiha
- multiméter Schneider
- multiméter Kyoritsu
- multiméter Brandson
- multiméter Stanley
- multiméter Silverline
- multiméter Rigol
- multiméter Projecta
- multiméter Multimetrix
- multiméter Weidmüller
- multiméter Laserliner
- multiméter Ideal
- multiméter Aldi
- multiméter Appa
- multiméter Amprobe
- multiméter Brennenstuhl
- multiméter Ferm
- multiméter Tacklife
- multiméter Somogyi
- multiméter Profile
- multiméter Steren
- multiméter Perel
- multiméter Flir
- multiméter Proline
- multiméter Hager
- multiméter Topcraft
- multiméter Clas Ohlson
- multiméter Altai
- multiméter Plieger
- multiméter Jung
- multiméter Etekcity
- multiméter Cablexpert
- multiméter Greenlee
- multiméter Högert
- multiméter Wago
- multiméter Bruder Mannesmann
- multiméter Keithley
- multiméter Metrel
- multiméter Digi-tool
- multiméter Skandia
- multiméter Elma
- multiméter Hubinont
- multiméter Kewtech
- multiméter Strex
- multiméter Mastech
- multiméter MBS
- multiméter MGL Avionics
- multiméter PCE Instruments
- multiméter Micronta
- multiméter CEM
- multiméter Horex
- multiméter Cosinus
- multiméter Kurth Electronic
- multiméter Testec
- multiméter IWH
- multiméter Weltron
- multiméter Sanwa
- multiméter Rohde & Schwarz
- multiméter EEVBlog
- multiméter Kingcraft
- multiméter HT Instruments
- multiméter Caltek
- multiméter Elworks
- multiméter Bearware
- multiméter Noyafa
Legújabb útmutatók multiméter

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

28 Március 2025

26 Március 2025

14 Január 2025