FED-2 Instruction manual
– – 1
FED 2
Fed-2 35mm FILM CAMERA instruction manual
This text is NOT identical to the one in the ocial Instruction Manual.
Fed-2 frontal View
01. Film Counter
02. Film wind knob
03. Rangender optic
04. Aperture index dot
05. Scale setting ring
06. Viewnder aperture
07. Automatic releaser button
08. Automatic releaser lever
09. Synchronizer socket
10. Front lens nut
11. Aperture setting ring
12. Depth of eld scale
13. Focusing ring
This manual contains a brief description of camera Fed-2 and the basic rules
for using the camera. It
cannot serve as a photography manual.
Slight dierences between the description and the camera may occur as a
result of technical
modication being introduced in the design of the camera.
Camera Fed-2 operated on standard 35 mm lm with a picture size of
24×36 mm. The great
resolving power of the lens makes it possible to
obtain perfect large-size pictures. The wide range of
shutter speeds,
the trigger winder, synchronizer, automatic releaser, dioptric view-nder setting, the
light weight and compactness of the camera will
satisfy the requirements of either amateur or
professional
photographer. The camera is tted with lens Industar-26M or with
Industar-61 with
lanthanum Optics. The camera is so designed that it
is also possible to use interchangeable lenses
Industar-50, Jupiter-9, Jupiter-11, Jupiter-12 and others. In taking a picture the camera
is focused with
the help of the range-nder. The automatic releaser
incorporated in the camera allows

FED-2 Instruction manual
– – 2
the photographer to take pictures
of himself. The automatic shutter speed ranging from 1/500 to
1/25
(1/30) sec permits the photographer to use the camera under any
lighting conditions. At the bottom of
the camera there is a socket
for a tripod. It is possible to photograph with a tripod without
taking the
camera out of its case.
Fed-2 rear View
14. Dioptric correction level
15. Rewind knob
16. Shutter speed selection knob
17. Shutter speed scale
18. Rewind release ring
19. Shutter release button
20. Frame counter disc
21. GOST lm speed reminder
22. Range and viewnder eyepiece
23. Accsessory shoe
24. Base locking latch.

FED-2 Instruction manual
– – 3
The camera can be loaded under ordinary soft lighting conditions in the
following way. By turning
the nut on the case bottom unscrew the tripod screw
retaining the camera, remove the camera from the
case. Raise the lock shackles
with the nail and turn them half-way round as far as they will go. Then
pressing with the thumbs, shift the camera back in such a way that its edge
comes out of the camera
slot and remove it.
Open the camera and take out the take-up reel and magazine. The reel is removed
with a certain
amount of eort. Load the magazine with lm (the magazine is
loaded in the darkness). Having pulled
out a free end of lm about 10cm long
from the magazine, fasten it on the reel in such a way that the
spring tooth
enters one of the perforations.
Fit the take-up reel on the bush and then place the magazine in the camera. At
this point the lm
should be slightly stretched and the teeth of the sprocket
should enter the perforations of the lm.
Close the camera.
The unexposed lm is fed to the picture aperture by winding the shutter twice
pressing the release
button after each winding. The winding lever should be
turned as far as it will go.
When properly loaded the camera is wound easily without jerky motions and
noticeable eorts.
Then by turning the dial scale set the O point of the“ ”
picture counter opposite the indicator. Align the
sensitivity scale dial with
the lm-type indicator index in accordance with the data of the lm loaded in
the camera. The lm indicator is a memory device consisting of a movable
sensitivity scale in lm
speed units (ASA, DIN) and a stationary indicator
with conventional designations of lm types.
The camera is equipped with lens Industar-26M or Industar-61“ ” “ ” with lanthanum
optics. The
scales are located on the lens mount. The diaphragm scale 1
indicates changes in the lens speed. When
focusing, the depth-of-eld scale 2
indicates on the distance scale the limits within which the range
sharpness
will be satisfactory for each selected diaphragm value. The distance scale serves for 3
focusing the lens. The scale designations correspond to the distance
from the object being
photographed to the surface of the lm in meters.
The camera is focused with the help of optical range-nder. In order to set
the camera at an accurate
and proper focus turn the lever of the dioptric
focusing, focus the view-nder by sight (the dioptric
focusing mechanism
provides a correction of ± diopters).
Termékspecifikációk
Márka: | FED |
Kategória: | nincs kategorizálva |
Modell: | 2 v1 |
Szüksége van segítségre?
Ha segítségre van szüksége FED 2 v1, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva FED
19 Augusztus 2024
18 Augusztus 2024
17 Augusztus 2024
16 Augusztus 2024
15 Augusztus 2024
Útmutatók nincs kategorizálva
- nincs kategorizálva Exped
- nincs kategorizálva Möhlenhoff
- nincs kategorizálva MantelMount
- nincs kategorizálva Luxul
- nincs kategorizálva Fortinge
- nincs kategorizálva Deaf Bonce
- nincs kategorizálva Insect Lore
- nincs kategorizálva Konica Minolta
- nincs kategorizálva Hartke
- nincs kategorizálva Dorman
- nincs kategorizálva Bazooka
- nincs kategorizálva Goodway
- nincs kategorizálva Phase One
- nincs kategorizálva Lervia
- nincs kategorizálva Indiana Line
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025