Installation & Operation
Inspection
• The following items are inside the box:
●UPS unit & User manual
• Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
re-pack the unit and return it to the place of purchase.
Connect to Utility Power
• Connect AC power cord to utility power. Then, the UPS will start
to charge inside battery. For best result, charge the battery for 6
hours prior to initial use.
Plug in Equipment
• Plug your equipment to Battery Backup Outlets on the rear panel
of the UPS.
• NOTE: Make sure that the UPS is powered on to protect all
important devices from data loss during power failure.
• CAUTION: NEVER connect a laser printer or scanner to the
battery backup outlets of UPS. The equipment may draw
significantly power to overload the UPS.
Turn On/Off the UPS
• Please transport the UPS system only in the original package to
protect against shock and impact.
Rear Panel
400-800VA
1000VA
1500-2000VA
A: Outlets
B: AC input
C: Fuse/Breaker
D: USB port
E: Surge protection
LCD Display
Operation Display
UPS
mode
LCD
Description
UPS
Power
on
When UPS is powered on, it
will enter this mode for 4
seconds.
AC Mode
When AVR is functioning,
icon will flash every
second.
LCD information will be
displayed in the following
order when LCD is touched.
1.Output voltage
2.Input voltage
3.Load level
4.Battery capacity
Overload
in AC
mode
icon will flash.
When overload occurs,
alarm will beep every 0.5
second.
Battery
Mode
When battery level is low,
icon will flash.
Alarm will beep every 10
seconds and LCD
information will be displayed
in the following order when
LCD is touched.
1.Output voltage
2.Input voltage
3.Load level
4.Battery capacity
Overload
in battery
mode
icon will flash.
When overload occurs,
alarm will beep every 0.5
second.
NOTE: If backlight shuts off, you may activate it by touching the screen.
Fault Code Table:
Fault condition
LCD
Solutions
Output short
circuited
Disconnect short-circuited loads and
restart the UPS again.
Overload fault
Disconnect all output loads and
restart the UPS again.
Overcharge
Call for service immediately.
Bad/severely
discharged
battery
Please replace the battery.
High output
voltage fault
Call for service immediately.
Over-
temperature
Call for service immediately.
If fault alarm occurs, please call for service immediately.
Line-interactive UPS
iFP 400VA~2KVA
FSP Manual Guide
EN
Termékspecifikációk
| Márka: | FSP |
| Kategória: | UPS |
| Modell: | iFP 800 |
Szüksége van segítségre?
Ha segítségre van szüksége FSP iFP 800, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók UPS FSP
30 Augusztus 2024
30 Augusztus 2024
29 Augusztus 2024
29 Augusztus 2024
29 Augusztus 2024
29 Augusztus 2024
28 Augusztus 2024
28 Augusztus 2024
28 Augusztus 2024
28 Augusztus 2024
Útmutatók UPS
- UPS Murr Elektronik
- UPS Riello
- UPS Minuteman
- UPS AEG
- UPS Ditek
- UPS Tripp Lite
- UPS Liebert
- UPS Lenovo
- UPS HP
- UPS Vanson
- UPS APC
- UPS Salicru
- UPS Eaton
- UPS Maruson
- UPS V7
Legújabb útmutatók UPS
9 Április 2025
9 Április 2025
3 Április 2025
3 Április 2025
31 Március 2025
31 Március 2025
31 Március 2025
30 Március 2025
29 Március 2025
29 Március 2025