Standby UPS
400VA/600VA/800VA
Inspection
The following items are inside the box:
UPS unit
User manual
Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
re-pack the unit and return it to the place of purchase.
Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to
charge inside battery. For best result, charge the battery for 6 hours
prior to initial use.
Plug in Equipment
Battery Backup Outlets(3)
Connect computer and monitor to the "Battery Backup" outlets.
These outlets provide battery backup, EMI filtering, line
conditioning, and surge protection. Battery power is automatically
provided in case of power failure.
Surge-Protected Outlets(3)
Connect a printer, fax machine, or scanner to the “Surge-protected”
outlets. These outlets do not provide power during power failure.
CAUTION: NEVER connect a laser printer or scanner to the
battery backup sockets of UPS. The equipment may draw
significantly power to overload the UPS.
Turn On/Off the UPS
To turn on the UPS unit, press the power switch lightly. Then, the
LED or LCD will light up. To turn off the UPS unit, press the power
switch again. Then, display will shut off.
1. LCD display or LED indicators
(Please check LED or LCD
section for the details)
2.
Power switch
3.
AC input
4.
Battery backup outlets
5.
Surge-protected outlets
6. USB port (option)
7.
Modem/phone/network surge
protection (option)
Operation Display
UPS
Mode
LCD
Description
UPS
Power on
When UPS is powered
on, it will enter this
mode for 4 seconds.
AC Mode
LCD information will be
displayed in the
following order when
LCD is touched.
1.
Output voltage
2.
Input voltage
3.
Load level
4.
Battery capacity
Overload
in AC
mode
icon will flash.
When overload occurs,
alarm will beep every
0.5 second.
Battery
Mode
When battery level is low,
icon will flash.
Alarm will beep every
10 seconds and LCD
information will be
displayed in the
following order when
LCD is touched.
1.
Output voltage
2.
Input voltage
3.
Load level
4.
Battery capacity
Overload
in battery
mode
icon will flash.
When overload occurs,
alarm will beep every
0.5 second.
NOTE: If backlight shuts off, you may activate it by touching the
screen.
Fault Code Table:
*Outlet type can be schuko,
UK or universal.
8.
Coax surge protection (option)
LED
Alarm
UPS Status
Green
Off
The mains is normal and
UPS is operated
normally.
Yellow
Sounding every
10 seconds
Power failure occurs and
UPS is on battery mode.
Yellow
Sounding every
second
Low battery
Green
Off
UPS is off.
Red
Continuously
sounding
UPS fault
LED on
LED Off
LED flashing
Fault condition
LCD
Solutions
Output short
circuited
Disconnect short-circuited
loads and restart the UPS
again.
Overload fault
Disconnect all output loads
and restart the UPS again.
Overcharge
Call for service immediately.
Bad or severely
discharged
battery
Please replace the battery.
High output
voltage fault
Call for service immediately.
If fault alarm occurs, please call for service immediately.