Használati útmutató Hager ECP140D

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Hager ECP140D (4 oldal) a Stoomkokers kategóriában. Ezt az útmutatót 21 ember találta hasznosnak és 7 felhasználó értékelte átlagosan 4.0 csillagra

Oldal 1/4
ECP140D
92
45
18
60
744
5 7
z i y
Technical dataTechnische dataDati tecnici
Data in compliance with EN 50470-1, EN 50470-3,
IEC 62053-21, IEC62053-23 and IEC 62053-31
Gegevens conform EN 50470-1, EN 50470-3, IEC 62053-21,
IEC 62053-23 en IEC 62053-31
Dati conformi alle norme EN 50470-1, EN 50470-3, IEC
62053-21, IEC62053-23 e IEC 62053-31
General characteristicsAlgemene karakteristiekenCaratteristiche generali
HousingDIN 43880BehuizingDIN 43880InvolucroDIN 43880DIN 1 0
MountingEN 60715MontageEN 60715MontaggioEN 6071535 mmDIN rail
DepthDiepte Profondità60mm
WeightGewicht Peso60g
Operating featuresBedieningsfunctiesFunzionalità operative
Connectionto single-phase network - number
of wiresVerbindingnaar eenfasig netwerk - aantal
draden Connessione alla rete monofase - numero di li-2
Storage of energy values
and conguration
Internal ash non volatile memoryOpslag van energiewaarden
en cong.
Intern ash niet-vluchtig geheugenMemorizzazione dei valori di
energia e congurazione
Memoria interna non volatile-c
Approval (according to EN 50470-1, EN 50470-3)Goedkeuring (volgens EN 50470-1, EN 50470-3)Omologazione (secondo EN 50470-1, EN 50470-3)
Reference Voltage (Un) (Un)Referentiespanning Tensione di riferimento 230(Un) VAC
Reference Current Referentie stroom Corrente di riferimento 5(Iref)(Iref)(Iref) A
Minimum Current Minimumstroom Corrente minima (Imin) (Imin) (Imin) A0.25
Maximum Current Maximale stroom Corrente massima 40(Imax)(Imax)(Imax) A
Starting Current Startstroom Corrente di avviamento (Ist)(Ist)(Ist)A 0.020
Reference Frequency Referentie frequentie Frequenza di riferimento 50(fn)(fn)(fn) Hz
Number of phases / number of wiresAantal fasen / aantal draden1 / 2Numero di fasi / numero di li-
Certied MeasuresGecerticeerde maatregelenMisure certicatekWh kWh kWh
AccuracyNauwkeurigheid Precisione
- Active Energies (accord. to EN 50470-3)- Reële energie (conform EN 50470-3)- Energia attiva (secondo EN 50470-3)classe B
- Active Powers (accord. to IEC 62053-21 and IEC 61557-12)- Reëel vermogen (conform IEC 62053-21 en IEC 61557-12)- Potenza attiva (secondo IEC 62053-21 e IEC 61557-12)classe 1
Supply Voltage and Power ConsumptionVoedingsspanning en EnergieverbruikTensione di alimentazione e potenza assorbita
Operating Supply Voltage rangeIntervallo tensione di alimentazione184 … 276Bedrfsspanningbereik V
Maximum Power Consumption (Voltage circuit)Maximaal energieverbruik (Spanningscircuit)Potenza massima assorbita (circuito voltmetrico)VA / W≤2 / ≤1
Maximum VA burden (Current circuit) @ Maximale VA last (stroom circuit) @ Massimo assorbimento VA (circuito amperometrico) @ ≤1ImaxImaxImax VA
Voltage Input WaveformMeetspanningsvormForma d'onda tensione di ingressoAC-
Voltage impedanceImpedantie spanningsingangImpedenza circuito voltmetrico1
Current impedanceImpedantie stroomingangImpedenza circuito amperometrico≤20
Overload capabilityOverbelastingscapaciteitCapacità di sovraccarico
VoltagecontinuousSpanning doorlopendTensionecontinuo276VAC
temporary (1 s)tdelk (1 s)temporaneo (1 s)VAC 300
CurrentcontinuousStroomdoorlopendCorrente continuo40A
temporary (10 ms)tdelk (10 ms)temporaneo (10 ms)A1200
Measuring FeaturesMeetfunctiesFunzioni di misura
Voltage rangeSpanningsbereikIntervallo di tensione184 … 276VAC
Current rangeStroombereikIntervallo di correnteA0.020 … 40
Frequency rangeFrequentiebereikIntervallo di frequenza45 … 65Hz
Measured QuantitiesGemeten hoeveelhedenQuantità misurateV, A, kWh, PF, Hz, kW-
Display featuresDisplay functiesCaratteristiche del display
Display typeLCDDisplay typeLCDTipo di
visualizzazione LCD -7.0 / 5.2
Active Energy5 digits + 2 decimal digitsReële EnergieEnergia attiva5 cifre + 2 cifre decimali5 cfers + 2 decimalenkWh 0.01 … 99999.99
Voltage3 digits + 2 decimal digitsSpanningTensione3 cifre + 2 cifre decimali3 cfers + 2 decimalenV184.00 … 276.00
Current2 digits + 2 decimal digitsStroomCorrente2 cifre + 2 cifre decimali2 cfers + 2 decimalenA0.00 … 40.00
Power factor1 digit + 2 decimal digits with sign + capac./
induc. indic.PowerfactorFattore di 1 cfer + 2 decimalen + capaciteit./induc. indic.potenza 1 cifra + 2 cifre decimali con segno + indic.
capac. / indutt.--1.00 … 1.00
Frequency2 digits + 2 decimal digitsFrequentieFrequenza2 cifre + 2 cifre decimali2 cfers + 2 decimalenHz 45.00 … 65.00
Active Power2 digits + 2 decimal digits with signReëel vermogenPotenza attiva2 cifre + 2 cifre decimali con segno2 cfers + 2 decimalen met tekenkW 0.00 … 11.04
Display refresh periodToon verversingsperiodeFrequenza di aggiornamento del display1s
Optical metrological LEDOptische metrologische LEDLED metrologico ottico
Front mounted red LED (meter
constant) proportional to active imp/
exp EnergyAan voorzde gemonteerde rode LED
(meter constant)evenredig met actieve
imp / exp EnergieLED rosso frontale (costante del
contatore) proporzionale all'energia
imp / exp. Attivap/kWh 5000
SafetyVeiligheid Sicurezza
Overvoltage categoryOverspanningscategorieCategoria di sovratensione3-
Protective classBeschermingsklasseClasse di protezioneIIclasse
AC voltage test (EN 50470-3, 7.2)AC spanningstest (EN 50470-3, 7.2)Test di tensione AC (EN 50470-3, 7.2)kV 4
Degree of pollutionVervuilingsgraadGrado di inquinamento2-
Operational voltageNominale spanningTensione di funzionamento300V
Impulse voltage test Impulsspanningstest Test di tensione ad impulso 6(Uimp)(Uimp)(Uimp) 1.2/50 μs-kV
Housing material ame resistanceUL 94UL 94Resistenza alla amma del materiale Behuizing materiaal vlamwerendheid
dell'involucro
UL 94classe V0
Ultrasonic safety welding between upper and lower housing
part Ultrasoon veiligheidslassen verbinden bovenste en onderste
behuizingsdelen Saldatura ad ultrasuoni di sicurezza tra la parte superiore e
quella inferiore della custodia-c
IR Connectable Communication ModulesIR-koppelbare communicatiemodulesModuli di comunicazione IR collegabili
For communication modulesVoor communicatiemodulesPer moduli di comunicazione-c
Pulse Outputs (S0 signals, acc. to IEC 62053-31)Pulsuitgangen (S0-signalen, conform IEC 62053-31)Uscite ad impulsi (segnali S0, secondo IEC 62053-31)
Pulse outputPulsuitgangUscite ad impulsikWh -
Pulse Rate (number of pulses per kWh)Pulsfrequentie (aantal pulsen per kWh)Frequenza degli impulsi (numero di impulsi per kWh)p/kWh 1000
Pulse ON durationDurata dell'impulso ON100Puls AAN duurms
Operating voltageNominale spanningTensione di funzionamentoVAC / VDC3 … 27.6 / ±5 … 39
Pulse ON maximum currentin the range 3 … 27.6 VAC / ±5 …
39 VDCPuls AAN maximale stroomin het bereik 3 … 27,6 VAC / ±5 …
39 VDCCorrente massima
dell'impulso ONnella gamma 3 … 27,6 VAC / ±5
… 39 VDCmA 90
Pulse OFF leakage currentin the range 3 … 27.6 VAC / ±5 …
39 VDCPulse "uit" lekstroomin het bereik 3 … 27,6 VAC / ±5 …
39 VDCImpulso OFF corrente di
dispersione nella gamma 3 … 27,6 VAC / ±5
… 39 VDCμA 1
Isolation classSELVIsolatieklasseSELVClasse di isolamentoSELVc
Environmental conditionsMilieuomstandighedenCondizioni ambientali
Storage temperature rangeOpslagtemperatuurTemperatura di stoccaggio-25 … +70°C
Operating temperature rangeTemperatura di funzionamento-25 … +55Bedrfstemperatuur °C
Mechanical environmentMechanische omgevingAmbiente meccanicoM1-
Electromagnetic environmentElektromagnetische omgevingAmbiente elettromagneticoE2-
Installationindoor onlyInstallatiealleen binnenInstallazionesolo all'interno-c
Altitude (max.)Hoogte (max.)Altitudine (max.)≤2000m
Humidityyearly average, without
condensation
Vochtigheid jaarlks gemiddelde, zonder
condensatie
Umiditàmedia annuale, senza condensa-≤75%
on 30 days per year, without
condensation
op 30 dagen per jaar, zonder
condensatie
su 30 giorni all'anno, senza
condensa
-≤95%
IP ratingIP ratingGrado di protezione IPin condizione di incasso (parte in built-in condition (front part)in ingebouwde conditie (voorkant)
frontale)
-IP51(*)
terminal blockklemblokmorsettieraIP20-
(*) For use in accordance with the MID Directive, the energy meter must be installed in a
distribution board/enclosure for modular products with a minimum protection rating IP30
The IP51 ratings apply to the meter parts exposed in front of (outside of) the cover of the
enclosure.
(*) Voor gebruik in overeenstemming met de MID-richtln moet de energiemeter
worden gemonteerd in een verdeelkast voor modulaire producten met een minimale
beschermingsklasse IP30. De IP51 is van toepassing op het gedeelte van de behuizing van
de energiemeter dat door de afdekplaat heen naar buiten steekt..
(*) Per l'utilizzo in conformità alla direttiva MID, il contatore di energia deve essere installato
in un quadro di distribuzione per apparecchi modulari con grado di protezione minimo
IP30. Il grado di protezione IP51 è relativo a parti del contatore esterne al quadro (frontale
dell'apparecchio).
Sealable terminal coverDimension
Verzegelbare
schroefklemafdekkap Afmetingen
Coprimorsetto sigillabileDimensione
z
i
y
Wiring diagram
Cable stripping length and terminal screw torque
Aansluitschema
Kabelstriplengte en aandraaimomenten van de
aansluitklemmen
Schema di collegamento
Lunghezza di sguainatura del cavo e coppia della
vite del morsetto
MID certied
MID gecerticeerd
Certicato MID
6LE005492Ad
1Hager Electro S.A.S., Boulevard d’Europe, B.P. 3, 67215 OBERNAI CEDEX, France - www.hager.comHager 09.196LE005492AdOCOM 136679