Oldal 1/11

SM210
RS485 - JBUS/MODBUS®for SM102E
§
User instructions

Contents
Preliminary operations ................................................... 1
General informations...................................................... 1
Installation ...................................................................... 2
Programmation............................................................... 3
Acces to programming mode (COde= 100) ....................... 3
Communication address............................................... 5
Communication speed ................................................. 6
Communication parity.................................................. 6
Communication stop bit ............................................... 7
To quit programming ................................................... 7
Communication .............................................................. 8
The standard communications frame............................... 8
Communication table................................................... 8
Technical characteristics ............................................... 8
Glossary of abbreviations.............................................. 8
§

Preliminary operations
1
For personnel and product safety please read the
contents of these operating instructions carefully before
connecting.
Check the following points as soon as you receive the
package:
• the packing is in good condition
• the product has not been damaged during transit
• the product reference number conforms to your order
• the package contains the product and the operating
instructions.
Functions
The optional IP Communication module must be connected
to the SM102E. It provides an RS485 serial link (2 or 3 wires)
with JBUS/MODBUS®protocol for the use of SM102E from
a PC or PLC.
General points
For a standard configuration, an RS485 link is used to
connect up to 31 SM102E or SM103E with a PC or a PLC
over a distance of 1200 metres, using JBUS/MODBUS
®
protocol.
Recommendations
You should use a shielded twisted pair (LIYCY type). In a
disturbed environment or large network (in terms of
length) we recommend the use of a shielded twisted pair
(type LIYCY-CY).
A repeater (1 channel) or an arrestor (4 channels) should
be used if you intend to exceed the distance (1200 m.)
and/or maximum number (31) of SM102E.
Please contact us for more information.
N.B.
A 120 ohm resistance (found on the additional module)
must be fixed at both ends of the link.
N N 1 n
R=120Ω R=120Ω R=120Ω
+ - - +
RS485
R=120 Ω
RS232
N N N 1 2 n
R=120Ω
RS485
R=120 Ω
RS232
General informations
PLC
PLC
~
–1200 M or 32 UL
~
–1200 M or 32 UL ~
–1200 M or 32 UL
Repeater
Termékspecifikációk
Márka: | Hager |
Kategória: | multiméter |
Modell: | SM210 |
Szüksége van segítségre?
Ha segítségre van szüksége Hager SM210, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók multiméter Hager
21 Augusztus 2024
21 Augusztus 2024
21 Augusztus 2024
21 Augusztus 2024
21 Augusztus 2024
21 Augusztus 2024
21 Augusztus 2024
21 Augusztus 2024
21 Augusztus 2024
21 Augusztus 2024
Útmutatók multiméter
- multiméter Klein Tools
- multiméter Gossen Metrawatt
- multiméter Emos
- multiméter Yato
- multiméter Vimar
- multiméter Elworks
- multiméter Clas Ohlson
- multiméter Gembird
- multiméter Brennenstuhl
- multiméter Aldi
- multiméter Keithley
- multiméter Fluke
- multiméter BaseTech
- multiméter Brandson
- multiméter Digi-tool
Legújabb útmutatók multiméter
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
28 Március 2025
26 Március 2025
14 Január 2025