Operating instructions
AS-i CompactModule M8
AC2488
AC2489
7390940/04 10/2018
UK

2
1 Preliminary note
Technical data, approvals, accessories and further information at
www.ifm.com.
1.1 Safety instructions
• Read this document before setting up the product and keep it during the entire
service life.
• The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
• Only use the product for its intended purpose (→ Functions and features).
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
• The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
• Installation, electrical connection, set-up, operation and maintenance of the
product must be carried out by qualified personnel authorised by the machine
operator.
• The plant manufacturer is responsible for the safety of the plant in which the
device is installed.
• If the device is used in a way that is not intended by the manufacturer, the
protection supported by the device may be impaired.
• Protect units and cables against damage.
1.2 Symbols used
► Instructions
> Reaction, result
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note

3
UK
2 Functions and features
• AC2488: 8 inputs CTT3 (AS-i profile S-7.A.A) / AS-interface version 3.0 /
master profile M4 / extended addressing mode: yes / maximum number of
modules per master: 62
• AC2489: 2x4 inputs (AS-i profile 2x S-0.A.E) / AS-interface version 3.0,
backwards compatible / master profile M3 or M4 / extended address mode:
yes / maximum number of modules per master: 31 (2 independent A/B slaves
per module)
3 Installation
► Disconnect power before installation.
► For installation choose a flat mounting surface.
The entire bottom of the module must lie flat on the mounting surface.
► Fix the module onto the mounting surface using M4 screws and washers.
4 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical equipment
must be adhered to.
► Disconnect the installation from power and connect the unit.
To ensure the protection rating:
► Connect the plugs of the sensors to the M8 sockets.
► Tighten firmly, recommended tightening torque 0.3...0.5 Nm.
► Cover the unused sockets with the enclosed protective caps.
► Tighten firmly, recommended tightening torque 0.3...0.5 Nm.
Termékspecifikációk
Márka: | IFM |
Kategória: | nincs kategorizálva |
Modell: | AC2488 |
Szüksége van segítségre?
Ha segítségre van szüksége IFM AC2488, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva IFM
9 Április 2025
9 Április 2025
9 Április 2025
23 Március 2025
23 Március 2025
18 Március 2025
18 Március 2025
18 Március 2025
18 Március 2025
16 Január 2025
Útmutatók nincs kategorizálva
- nincs kategorizálva TrueLife
- nincs kategorizálva IK Multimedia
- nincs kategorizálva HIOAZO
- nincs kategorizálva Auto XS
- nincs kategorizálva Aligator
- nincs kategorizálva H-Tronic
- nincs kategorizálva Sole Fitness
- nincs kategorizálva Dualit
- nincs kategorizálva Real Cable
- nincs kategorizálva PKM
- nincs kategorizálva Gravity
- nincs kategorizálva Profoto
- nincs kategorizálva Cosina
- nincs kategorizálva Verbos Electronics
- nincs kategorizálva Laserluchs
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025