Operating instructions
AS-i PCB module
AC2750
AC2751
AC2752
AC2753
80285129/00 04/2019
UK

2
1 Preliminary note
An instruction is indicated by "►".
Example: ► Mount the unit as shown.
Important note
Non-compliance can result in malfunction or interference.
2 Safety instructions
• Please read the operating instructions prior to set-up of the device.
• Ensure that the product is suitable for your application without any restrictions.
• The unit conforms to the relevant regulations and EC directives.
• Improper or non-intended use may lead to malfunctions of the unit or to
unwanted effects in your application.
• Installation, electrical connection, set-up, operation and maintenance of the
unit must only be carried out by qualified personnel authorised by the machine
operator.
3 Functions and features
The AS-i module functions as digital I/O slave in the AS-i system and is exclusively
supplied via AS-i. It connects 4 sensors (2-wire sensors or 3-wire sensors) and
max. 4 actuators (pnp) with the AS-i master.
• Maximum number of modules per master: 62 (A/B slave)
• Watchdog function: If the connection to the master is interrupted for more than
40 ms, all outputs are disconnected.
• AS-Interface version 3.0, downward compatible
4 Installation
► Disconnect the system from power before installation.
► Install the module in a protected location, e.g. in a housing with at least IP 54.
Use the supplied adhesive pad or the DIN rail adapter E70432 (accessory) for
fixing.
► When using the adhesive pad, the surfaces must be kept free from dust, oil,
release agents and other kinds of contamination.

3
UK
► Position the adhesive pad in the centre of the back of the PCB module.
► Carry out a set-up test after installation of the module.
5 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical equipment
must be adhered to.
► Disconnect the installation from power and connect the unit.
5.1 External protective circuitry for inductive loads
The switch-on and switch-off capacity for triggering solenoids is rated up to 2.5 W
(IEC 60947-5-1, utilisation category DC-13).
Recommendation: For inductive loads use a free wheel diode on the load.
5.2 Wiring
AC2750 (4 DI / 4 DO) / AC2751 (4 DI / 3 DO)
Connection cables
I1 WH (white)
I2 WH (white)
I3 WH (white)
I4 WH (white)
O1 YE (yellow)
O2 YE (yellow)
O3 YE (yellow)
O4 YE (only AC2750)
0- BK (black)
I+ RD (red)
AS-i - (FLT) BU (blue)
AS-i + (PWR) BN (brown)
Switching input sensor 1
Switching input sensor 2
Switching input sensor 3
Switching input sensor 4
Switching output actuator 1
Switching output actuator 2
Switching output actuator 3
Switching output actuator 4
Sensor and actuator supply 0 V
Sensor and actuator supply 24 V
AS-i -
AS-i +
Termékspecifikációk
Márka: | IFM |
Kategória: | nincs kategorizálva |
Modell: | AC2750 |
Szüksége van segítségre?
Ha segítségre van szüksége IFM AC2750, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva IFM
9 Április 2025
9 Április 2025
9 Április 2025
23 Március 2025
23 Március 2025
18 Március 2025
18 Március 2025
18 Március 2025
18 Március 2025
16 Január 2025
Útmutatók nincs kategorizálva
- nincs kategorizálva Empress Effects
- nincs kategorizálva EZ Dupe
- nincs kategorizálva Mobli
- nincs kategorizálva Phil And Teds
- nincs kategorizálva JLab
- nincs kategorizálva Prologue
- nincs kategorizálva Musser
- nincs kategorizálva 3B
- nincs kategorizálva M-Audio
- nincs kategorizálva Max Pro
- nincs kategorizálva Vaddio
- nincs kategorizálva FontaFit
- nincs kategorizálva Rikon
- nincs kategorizálva Vasagle
- nincs kategorizálva Vroomshoop
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025