Installation Instructions
Electronic pressure sensor
for industrial applications
PC3504
704967 / 00 12 / 2010
UK

2
1 Safety instructions
• Please read this document prior to installing the unit. Ensure that the product is
suitable for your application without any restrictions.
• If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
• Please check for all applications that the product materials (see Technical data)
are compatible with the media to be measured.
For the scope of validity cULus:
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated either
a) max 5 amps for voltages 0~20 Vrms (0~28.3 Vp) or
b) 100/Vp for voltages of 20~30 Vrms (28.3~42.4 Vp).
2 Function and features
The pressure sensor detects the system pressure and converts it into an analogue
output signal (4 ... 20 mA).
2.1 Applications
• Type of pressure: relative pressure
Order no. Measuring range Permissible
overload pressure
Bursting
pressure
bar PSI bar PSI bar PSI
PC3504 0...16 0...232 25 362 300 4351
MPa = bar ÷ 10 / kPa = bar × 100
Contents
1 Safety instructions ................................................................................................2
2 Function and features ...........................................................................................2
2.1 Applications ....................................................................................................2
3 Installation ............................................................................................................3
4 Electrical connection.............................................................................................3
5 Scale drawing .......................................................................................................4
6 Technical data .......................................................................................................5

3
UK
Static and dynamic overpressures exceeding the indicated overload pres-
sure are to be avoided by taking appropriate measures.
The indicated bursting pressure must not be exceeded. Even if the burst-
ing pressure is exceeded only for a short time, the unit can be destroyed.
NOTE: Risk of injury!
3 Installation
Before mounting and removing the sensor, make sure that no pressure is
applied to the system.
► Insert the unit in a G¼ process connection.
► Tighten firmly. Tightening torque: max. 25 Nm.
4 Electrical connection
The unit must only be connected by an electrician.
The national and international regulations for the installation of electrical
equipment must be observed.
Voltage supply to EN50178, SELV, PELV..
► Disconnect power.
► Connect the unit as follows:
Core colours of ifm sockets:
1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black),
n.c. = not connected.
Termékspecifikációk
Márka: | IFM |
Kategória: | nincs kategorizálva |
Modell: | PC3504 |
Szüksége van segítségre?
Ha segítségre van szüksége IFM PC3504, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva IFM
9 Április 2025
9 Április 2025
9 Április 2025
23 Március 2025
23 Március 2025
18 Március 2025
18 Március 2025
18 Március 2025
18 Március 2025
16 Január 2025
Útmutatók nincs kategorizálva
- nincs kategorizálva Plantronics
- nincs kategorizálva VAEMI
- nincs kategorizálva Napoleon
- nincs kategorizálva Gianni Ferrari
- nincs kategorizálva Reishunger
- nincs kategorizálva Mulex
- nincs kategorizálva Gridbyt
- nincs kategorizálva MaxCom
- nincs kategorizálva Gaggenau
- nincs kategorizálva Viscount
- nincs kategorizálva Tele Vue
- nincs kategorizálva Caple
- nincs kategorizálva Oster
- nincs kategorizálva Melitta
- nincs kategorizálva Profoto
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025