Short instructions
Cooling water control panel
ZZ0432
80000588 / 00 10 / 2021
UK
UK
UK
UK
UK
2
1 System overview
1
3 4 5
350
360
33
426,8
129,1
M22x1,5R
½
2
67
8
1 Flow sensor Monitors and indicates the cooling water flow rate.
The setting of two switch points enables detection of:
- excess flow (leakage / burst pipes / lost tips),
- low flow (clogged /damaged pipes).
3
UK
2 Water stop valve Closes the water supply to the system in case of failure and
prevents water spillage.
3 Backstop Prevents cooling water loss through the return pipe in case of
failure (broken tip / burst pipe).
4 Regulating valve Continuous regulation of the flow rate.
5 Pressure sensor Monitors the operating pressures, very fast response times are
attained if pressure falls (broken tips).
6 Expansion
cylinder
When a welding tip is replaced or if there is a fault (2/2-way
valve in the inlet pipe is closed), the expansion cylinder actively
sucks back the cooling water and switches off the pressure.
7 5/2-way valve The 5/2-way valve controls the expansion cylinder.
8 tube connection Ø 8 mm
► →Observe the instructions of the sensors www.ifm.com.
2 Functions and features
Pressure Equipment Directive (PED)
The units comply with the Pressure Equipment Directive and are designed
and manufactured for group 2 fluids in accordance with the sound engineering
practice.
Use of group 1 fluids on request.
3 Setting of the flow sensor
The flow sensor monitors the flow rate in the supply pipe by means of a window
function. This is achieved by setting the output function of the two outputs:
OU1 and OU2 = Fno, window / normally open. With this setting an acceptable
range is monitored.
The flow rate depends on the water supply and the set-up of the welding tongs.
The setting of the switch-on points (SP1, SP2) and the switch-off points (rP1, rP2)
depends on the installation.
Optimum monitoring of the start up characteristics as well as processrelated flow
fluctuations during operation is possible via additional monitoring times in the
robot software.

Termékspecifikációk

Márka: IFM
Kategória: nincs kategorizálva
Modell: ZZ0432

Szüksége van segítségre?

Ha segítségre van szüksége IFM ZZ0432, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva IFM

IFM

IFM E40581 Útmutató

9 Április 2025
IFM

IFM O3R252 Útmutató

9 Április 2025
IFM

IFM PG1704 Útmutató

9 Április 2025
IFM

IFM PE2599 Útmutató

23 Március 2025
IFM

IFM MK5312 Útmutató

23 Március 2025
IFM

IFM RU6035 Útmutató

18 Március 2025
IFM

IFM SF3210 Útmutató

18 Március 2025
IFM

IFM RU6045 Útmutató

18 Március 2025
IFM

IFM KI0200 Útmutató

18 Március 2025
IFM

IFM PT2400 Útmutató

16 Január 2025

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva