Használati útmutató Jung 1702SE

Jung kapcsoló 1702SE

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Jung 1702SE (7 oldal) a kapcsoló kategóriában. Ezt az útmutatót 19 ember találta hasznosnak és 10 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/7
LB management
LB management
LB management
LB managementLB management
Relay switch insert 2-channel
Relay switch insert 2-channel
Relay switch insert 2-channel
Relay switch insert 2-channel
Relay switch insert 2-channelRelay switch insert 2-channel
Art. no.: 1702SE
Operating instructions
Operating instructions
Operating instructions
Operating instructionsOperating instructions
1
1
1
11 Safety instructions
Safety instructions
Safety instructions
Safety instructionsSafety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.
Electrical devices may only be mounted and connected by electrically skilled persons.Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Serious injuries, fire or property damage possible. Please read and follow manual fully.Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the device or load.
Danger of electric shock. Always disconnect before carrying out work on the device or load.
Danger of electric shock. Always disconnect before carrying out work on the device or load.
Danger of electric shock. Always disconnect before carrying out work on the device or load.Danger of electric shock. Always disconnect before carrying out work on the device or load.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.
These instructions are an integral part of the product, and must remain with the end customer.These instructions are an integral part of the product, and must remain with the end customer.
2
2
2
22 Intended use
Intended use
Intended use
Intended useIntended use
Switching of lighting and motors
Mounting in appliance box according to DIN 49073
Operation with suitable cover from LB management
3
3
3
33 Product characteristics
Product characteristics
Product characteristics
Product characteristicsProduct characteristics
In combination with 2-gang push-button top
Two independent outputs
Time function for output a2
a2
a2
a2a2 adjustable
Connection of extensions possible
In combination with 1-gang push-button top
Output a2
a2
a2
a2a2 switches depending on output a1
a1
a1
a1a1 e.g. to switch on ventilation, depending on the
lighting, and switch it off with a delay.
Switch-on delay of output a2
a2
a2
a2a2 adjustable
Switch-off delay for output a2
a2
a2
a2a2 can be preset
Connection of extensions possible
4
4
4
44 Operation with 2-gang push-button top
Operation with 2-gang push-button top
Operation with 2-gang push-button top
Operation with 2-gang push-button topOperation with 2-gang push-button top
Switch load
Switch load
Switch load
Switch loadSwitch load
Left: operation of output a1
a1
a1
a1a1.
Right: operation of output a2
a2
a2
a2a2.
Press push-button.
Output a1
a1
a1
a1a1, a2
a2
a2
a2a2 switches on and off.
Extension unit operation
Extension unit operation
Extension unit operation
Extension unit operationExtension unit operation
Operation via 3-wire extension with 2-gang push-button top: Press top to switch on, press bot-
tom to switch off.
A 2-wire extension or push-button always switches both outputs.
Rotary dimmer extension only switches output a1
a1
a1
a1a1.
Time function
Time function
Time function
Time functionTime function
If a time function is set for output a2
a2
a2
a2a2 (see Setting the time function/switch-off delay), it switches
off after the set time has expired. The time function starts as soon as output a2
a2
a2
a2a2 is switched on.
To terminate the time function prematurely, output a2
a2
a2
a2a2 must be switched off manually.
The time function cannot be restarted by pressing again.
1 / 7
82401733 07.01.2021
J0082401733

Termékspecifikációk

Márka: Jung
Kategória: kapcsoló
Modell: 1702SE

Szüksége van segítségre?

Ha segítségre van szüksége Jung 1702SE, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók kapcsoló Jung

Jung

Jung W8180 Útmutató

10 December 2024
Jung

Jung 201TE Útmutató

10 December 2024
Jung

Jung BTA17102 Útmutató

2 Október 2024
Jung

Jung ASLS1280-1 Útmutató

20 Szeptember 2024
Jung

Jung BTLC17102P Útmutató

15 Szeptember 2024
Jung

Jung ME5201DTU Útmutató

3 Szeptember 2024
Jung

Jung BTES17101 Útmutató

2 Szeptember 2024
Jung

Jung 1701PSE Útmutató

31 Augusztus 2024
Jung

Jung SL1180 Útmutató

26 Augusztus 2024
Jung

Jung AS5544.03VWW Útmutató

26 Augusztus 2024

Útmutatók kapcsoló

Legújabb útmutatók kapcsoló

Tork

Tork SS700ZA Útmutató

9 Április 2025
Cudy

Cudy FS1024 Útmutató

9 Április 2025
Lancom

Lancom GS-2412 Útmutató

5 Április 2025
Lancom

Lancom GS-2412P Útmutató

5 Április 2025
Lancom

Lancom GS-2426 Útmutató

5 Április 2025
Lancom

Lancom GS-2426P Útmutató

5 Április 2025
Hager

Hager ARF970D Útmutató

3 Április 2025
Hager

Hager ARF920D Útmutató

3 Április 2025