Használati útmutató Kern FS 2-5KOY1
Kern
Mérőberendezések
FS 2-5KOY1
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Kern FS 2-5KOY1 (2 oldal) a Mérőberendezések kategóriában. Ezt az útmutatót 16 ember találta hasznosnak és 8.5 felhasználó értékelte átlagosan 4.1 csillagra
Oldal 1/2

Sauter GmbH
Ziegelei 1
D-72336 Balingen
E-mail: info@kern-sohn.com
Tel. : +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.sauter.eu
Manual
SAUTER FS
V. 1.0
01/2022
EN
FS-BA-en-2210.docx
Measuring channel CH2
Measuring channel CH1
Interface socket
(optional)
Measuring channel
CH4 (optional)
Measuring channel
CH3 (optional)

2 FS-BA-en-2210.docx
EN
SAUTER FS
V. 1.0 01/2022
Manual
Congratulations on your purchase of a digital force gauge with internal or external
measuring cell from SAUTER. We hope you enjoy your quality measuring device with
its wide range of functions. If you have any questions, requests or suggestions, please
do not hesitate to contact us.
Table of contents:
1 Introduction .................................................................................................... 5
2 Check before use ........................................................................................... 5
3 Intended use ................................................................................................... 5
4 Warnings ........................................................................................................ 5
4.1 Transport ................................................................................................................................... 5
4.2 Electrostatic sensitive device ................................................................................................. 5
4.3 Risk of accident ........................................................................................................................ 6
4.4 Damage / defective equipment ................................................................................................ 6
4.5 Accuracy ................................................................................................................................... 6
4.6 Maximum measuring range ..................................................................................................... 7
5 Available models............................................................................................ 7
6 Scope of delivery ........................................................................................... 8
7 Connections ................................................................................................... 8
7.1 USB C socket ............................................................................................................................ 8
7.2 Connection sockets for external sensors .............................................................................. 9
7.2.1 Compatibility and necessary accessories .................................................................................. 9
7.2.2 Plug & play from external sensors .............................................................................................. 9
7.2.3 Pin assignment connector ........................................................................................................ 10
7.3 Expansion from 2 to 4 measuring channels ........................................................................ 10
7.4 Connection socket for optional data interface .................................................................... 10
8 Technical data .............................................................................................. 10
8.1 Battery ..................................................................................................................................... 10
8.2 Display and measurement ..................................................................................................... 11
8.3 Temperature ............................................................................................................................ 11
8.3.1 Storage temperature ................................................................................................................. 11
8.3.2 Use temperature ....................................................................................................................... 11
8.4 Fastening option ..................................................................................................................... 12
Termékspecifikációk
Márka: | Kern |
Kategória: | Mérőberendezések |
Modell: | FS 2-5KOY1 |
Szüksége van segítségre?
Ha segítségre van szüksége Kern FS 2-5KOY1, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Mérőberendezések Kern
1 Április 2025
1 Április 2025
1 Április 2025
1 Április 2025
1 Április 2025
1 Április 2025
1 Április 2025
1 Április 2025
1 Április 2025
1 Április 2025
Útmutatók Mérőberendezések
- Mérőberendezések ZKETECH
- Mérőberendezések HT Instruments
- Mérőberendezések Pancontrol
- Mérőberendezések Rotronic
- Mérőberendezések SecuTech
- Mérőberendezések Greisinger
- Mérőberendezések MSW
- Mérőberendezések Zircon
- Mérőberendezések Sauter
- Mérőberendezések Eltako
- Mérőberendezések Seaward
- Mérőberendezések Hikmicro
- Mérőberendezések Midland
- Mérőberendezések VirtuFit
- Mérőberendezések Topex
Legújabb útmutatók Mérőberendezések
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025