GlucoTeq - BGM 200
IB BGM 200_mg EN 5120 - Revision Date: 2020-12-11
Explanation of Symbols
For In vitro diagnostic use Temperature limitation
Please consult instructions for use Use by / Expiry date
Do not reuse Manufacturer
Lot number Caution, consult accompanying document
Keep dry Keep away from sunlight
Humidity limitation EU representative
This product fulfils the requirements of Directive 98/79/EC in vitro diagnostic medical 
device.
Do not use if package is damaged Serial number
Wholecare 
Biomedical Corporation
8F, 443, RuiGang Road, NeiHu
Taipei, 11492, Taiwan
Medical Device Safety Service GmbH
(MDSS GmbH)
Schiffgraben 41
30175 Hannover / Germany
LOT
0123
0123
Overview
1.Before you begin
2.Getting to know your system
3.Prepare for blood sampling
4.Performing blood test
5.Alternative site testing
6.Control solution testing
7.Memory recall
8.Caring for your meter and test strip
9.Specifications
10.System Troubleshooting
11.Performance Characteristics
12.Guarantee
1. Before you begin
Please read this before using.
The following basic safety precautions should always be taken.
1.Close supervision is necessary when the device is used by, on, or near children or people with disabil-
ities.
2.Use the device only for the intended use described in this user guide.
3.Do not use test strips and control solutions which are not supplied by the manufacturer.
4.Do not use the device if it is not working properly, or if it has suffered any damage.
5.Before using any product to test your blood glucose, read all instructions thoroughly and practice the 
test. Do all quality control checks as directed and consult with a diabetes healthcare professional.
Keep this user guide with you.
Intended use:
Principle of Measurement
Blood glucose is measured by an electrical current that is produced when a blood sample mixes with 
the reagent (special chemicals) of the test strip. The electrical current changes with the amount of 
glucose in the blood sample. The Microlife GlucoTeq meter measures the strength of the electrical 
current, calculates your blood glucose level and then displays your result in either milligrams of glucose 
per deciliter (mg/dL) or millimoles of glucose per liter (mmol/L).
Caution
1.The user should not take any decision of medical relevance without first consulting his or her medical 
practitioner.
2.Call your doctor immediately if you experience symptoms that are not consistent with your blood 
glucose test results.
3.High altitudes above 3,402 meter (11,161 ft) may affect the test results.
4.Temperatures outside the range of 10°C to 40°C (50°F to 104°F) may affect the test results. Do not 
test outside of these temperature ranges.
5.Do not perform servicing and maintenance while the meter is in use.
6.Modification of this equipment is not allowed. If the equipment is used in a manner not specified by 
the manufacturer, the protection provided by the equipment may be impaired.
7.Do not use this meter near cellular or cordless telephones in a call, walkie-talkies, garage door 
openers, radio transmitters, or other electrical or electronic equipment that are sources of electromag-
netic radiation, as these may interfere with the proper operation of the meter.
Important Health-Related Information
1.Apply only capillary whole blood sample to test your blood glucose. Applying other substances or 
plasma, serum will cause wrong results.
2.Severe dehydration and excessive water loss may cause false low results. If you believe you are 
suffering from severe dehydration, consul essional immediately.t your healthcare prof
3.Test results below 60 mg/dL (3.3 mmol/L)*1 indicates low blood glucose (hypoglycemia). Test results 
greater than 240 mg/dL (13.3 mmol/L)*2 indicates high blood glucose (hyperglycemia).If your results 
are below 60 mg/dL (3.3 mmol/L) or above 240 mg/dL (13.3 mmol/L), repeat the test, and if the results 
are still below 60 mg/dL (3.3 mmol/L) or above 240 mg/dL (13.3 mmol/L), consult your healthcare 
professional immediately.
4.Inaccurate results may occur in severely hypotensive individuals or patients in shock. Inaccurate low 
results may occur for individuals experiencing a hyperglycemic-hyperosmolar state, with or without 
ketosis. Critically ill patients should not be tested with blood glucose meters.
5.Abnormal red blood cell counts may cause false results. Please consult your healthcare professional 
if you do not know your hematocrit level.
6.Interference: Reducing substances occurring in the blood naturally (uric acid, bilirubin) or from thera-
peutic treatments (ascorbic acid, acetaminophen) will not significantly affect Microlife GlucoTeq test 
results. However, elevated concentrations of these substances may affect test results. The 
compounds listed in the table were found to have no affect at the concentration indicated.
REFERENCE:
Kahn, R. and Weir, G.: Joslinis Diabetes Mellitus, 13thed Philadelphia: Lea and Febiger (1994), 489. *1
Krall, L.P. and Beaser, R. S.: Joslin Diabetes Manual. Philadelphia: Lea and Febiger (1989), 261-263. *2
2. Getting to know your System
The Microlife GlucoTeq Glucose Monitoring System
The Microlife GlucoTeq system uses the latest technology to provide you with easy and comfortable 
testing. The system requires only 0.5uL blood sample to complete the testing in only 5 seconds.
Please review the contents of your purchase to confirm that all the components are included as listed 
on the side of your meter box.
The system is intended for use outside the body (in vitro diagnostic use only). It should be used 
only for self-testing blood glucose (blood sugar) and only with fresh capillary whole blood 
samples. The system is intended for use in the home and in clinical settings. The system should 
not be used for the diagnosis of diabetes or for the testing of newborns.
Compounds Concentrations higher than the following values may cause 
inaccurate results
Acetaminophen 8.0 mg/dL (0.53 mmol/L)
Ascorbic Acid 5.0 mg/dL (0.28 mmol/L)
Aspirin 60 mg/dL (3.33 mmol/L)
Bilirubin 90 mg/dL (1.54 mmol/L)
Cholesterol 500 mg/dL (12.9 mmol/L)
Creatinine 5.0 mg/dL (0.44 mmol/L)
Dopamine 2.0 mg/dL (0.11 mmol/L)
EDTA 360 mg/dL (12.3 mmol/L)
Galactose 900 mg/dL (50 mmol/L)
Gentisic Acid 5.0 mg/dL (0.32 mmol/L)
Glutathione 53 mg/dL (1.72 mmol/L)
Haemoglobin 500 mg/dL (0.08 mmol/L)
Heparin 8,000 U/dL
Hydroxyurea 3.0 mg/dL (0.39 mmol/L)
Ibuprofen 50 mg/dL (2.42 mmol/L)
Icodextrin 13 mg/dL (0.01 mmol/L)
L-dopa 10 mg/dL (0.51 mmol/L)
Maltose 900 mg/dL (26.3 mmol/L)
Methyldopa 3.0 mg/dL (0.13 mmol/L)
Pralidoxime Iodide 25 mg/dL (0.94 mmol/L)
Salicylate 60 mg/dL (4.34 mmol/L)
Tolazamide 100 mg/dL (3.21 mmol/L)
Tolbutamide 400 mg/dL (14.8 mmol/L)
Triglycerides 2,000 mg/dL (22.6 mmol/L)
Uric Acid 8.0 mg/dL (0.48 mmol/L)
Xylose 100 mg/dL (6.66 mmol/L)
1Illuminated Test Strip Slot
Insert the test strip here. The meter will turn on auto-
matically and the slot LED light will illuminate.
To track the position of test strip slot without strip 
inserting, press main button
and the slot LED light will be flashing.
2LCD Display
Guides you through the test using symbols and 
simple messages.
3Main Button
Turns the meter on or performs other functions 
described in this user guide.
4Data Port
Allows you to transfer the information stored in the 
meter to a computer to view, analyze and print.
5Set Button
Located on the back of the meter, inside the battery 
compartment; used to set up the meter.
6Battery Compartment
Holds ONE 3V Lithium battery (battery type 
CR2032). Please install battery into meter before 
you start testing.
7Meter Label
Each meter has its unique number on it. Do not alter 
or tear the label off.
vcc
GND
1
2
33
4
5
6
7
If any part of the display is not working, contact your local distributor for help.
Battery
Microlife GlucoTeq meters come with one (1) CR2032 lithium battery. The battery is manufactured in a 
charged state and not designed for recharging. Recharging the battery can cause battery leakage, or 
in some cases, high pressure rupture.
Warning: Batteries can explode or leak and cause burns if installed backwards, disassembled, 
charged or exposed to water, fire or high temperatures.
Low Battery
The meter will alert you when the power is getting low by displaying two different messages:
When the battery symbol AR appears alone on the display, the meter is functional and the results 
remain accurate, but you should change the battery as soon as possible.
When the battery symbol AR appears together with the «E-b» symbol on the display, the battery does 
not have enough power for a test. You must change the battery before using the meter.
Replacing the battery does not affect the meter’s memory (previous test results stored in 
memory). However, the date, time and unit settings may need to be updated; update the settings 
by following the steps in «Setting Time and Date». 
As with all small objects, the battery should be kept away from small children. If the battery is swal-
lowed, seek medical assistance immediately.
Remove the battery if you are not going to use the device for a long period of time (i.e. 3 months 
or more), or the battery might leak chemicals.
Please discard the product or the batteries properly according to the regulations of your country.
Setting Mode
Please install battery first and complete the setting before you begin to test.
8Contact Bars
Insert this end of the test strip into the meter. Push 
it in firmly until it will not go any further.
9Test Strip Handle
Hold this part to insert the test strip into the test strip 
slot on the meter.
AT Confirmation Window
Shows whether enough blood has been drawn into 
the test strip’s absorbent channel.
AK Absorbent Channel
Apply a drop of blood and it will be drawn in auto-
matically.
AL Test Result Area
Displays test results.
AS Unit of Measure
Indicates what unit of measure 
the test result is displayed in.
AM Appears when test result is 
lower than 70 mg/dL (3.9 
mmol/L) or higher than 180 
mg/dL (10 mmol/L).
BT Temperature Symbol
Appears when temperature is 
outside of operating range.
Appears when test result is 
within the range of 70 to 120 
mg/dL (3.9 mmol/L to 6.7 
mmol/L).
BK Control Solution Test 
Symbol
Shows that you are in control 
solution mode.
AN Ketone Symbol
Appears when test result is 
higher than 240 mg/dL (13.32 
mmol/L).
BL Memory Symbol
Appears when you review the 
memory.
AO Alarm Symbol
Appears when you are 
setting alarms.
BM After Meal
Indicates that your test is an 
After Meal test.
AP Test Strip Symbol
Appears when the meter is in 
testing mode.
BN Before Meal
Indicates that your test is a 
Before Meal test.
AQ Blood Drop Symbol
Flashes when sample should 
be applied.
BO Date
AR Low Battery Symbol
Appears when the battery 
power is low.
BP Time
STEP 1: With the meter off, press 
the   mark on the battery cover 
and slide up to open the cover.
STEP 3: Replace with a new 
battery. Be sure to align the 
battery properly with the positive 
(+) side up.
STEP 2: Remove the old battery 
by pressing on the buckle beside 
the battery and gently pulling it at 
the same time.
STEP 4: Close the battery cover. 
If the meter does not power on 
and enter setting mode after you 
have replaced the battery, check 
that the battery is correctly 
installed.
STEP 1: Enter Setting Mode
If your meter is off, press the SET 
button 5 located in the battery 
compartment. The meter is now 
in the setting mode.
STEP 4: Set the Date
Press and release the main button 
3
 to advance the date. With the 
correct date on the display, press 
the 
SET
 button 
5
 and the time 
will appear on the display with the 
hour segment flashing.
STEP 2: Set the Year
Press and release the main button 
3
 to advance the year. With the 
correct year on the display, press 
the 
SET
 button 
5
 and the date 
will appear on the display with the 
month segment flashing.
STEP 5: Set the Hour
Press and release the main 
button 3 to advance the hour. 
With the correct hour on the 
display, press the SET button 5 
and the minutes segment will 
start flashing.
STEP 3: Set the Month
Press and release the main button 
3
 to advance the month. With the 
correct month on the display, 
press the 
SET
 button 
5
 and the 
date segment will start flashing.
STEP 6: Set the Minutes
Press and release the main 
button
3
 to advance the minutes. 
With the correct minutes on the 
display, press the 
SET
 button 
5
and the 
«OFF»
 will start flashing.
Fig. A STEP 7: Set the Alarm
The meter allows you to set 4 different alarms with an order from 1 to 4.   
will be displayed during the alarm setting.
Fig. B 1 - Press the main button3 to turn the alarm ON (Fig.A) or OFF (Fig.B).
2 - Press SET button 5 to move to hour setting for alarm. (Fig.C) Use the 
main button 3 to set your desired hour. 
Press SET button5 again to set the minute. (Fig.D).
Fig. C 3 - Press SET button to set the next alarm.
4 - Repeat step 1-3 to set the second, third and fourth alarm. 
After completing fourth alarm, the AC/PC will start flashing.
Fig. D
STEP 8: Set AC/PC
Press and release the main button   to select ON/OFF. With the correct 3
setting, press the SET button 5 for confirmation.
STEP 9: Delete Memory
If you do not want to clear the memory, press the SET button again to skip 
this step.
If you want to clear ALL memory, press the main button for five (5) seconds. 
The «- - -» will appear to indicate all memory has been deleted and the meter 
will turn off.
STEP 10: Complete Setting
Setup is now complete. «OFF» is displayed and the meter will turn off.
8
9 AT
AK
AL
AM
AN
AO AP AQ
AR
AS
BT
BK
BL
BM
BN
BP BO
vcc
GND
vcc
GND
vcc
GND
vcc
GND
3. Prepare for blood sampling
If your lancing device did not come with a lancing device insert, the following information shall take 
the place of the insert.
Microlife LD-100 Lancing Device
Your lancing device and lancets are used for obtaining blood samples from the puncture site.
Special Features
Intended Use: The lancing device is intended for use by a single person with the lancet puncturing 
through the skin for collecting blood sample.
Safety Switch design: when the depth adjustable cap is open, the trigger will be relieved automatically 
which prevents users from being pricked if you are not intended to start the test. You can eject the used 
disposable lancet on one hand operation by pushing the plunger with your thumb at this status.
When the cap is closed, it will lock the lancet eject function and prevent the lancet from being removed 
when you are intended to start the test.
Stable and sophisticated structure design ensures almost no vibration, so that the lancet pricking is 
steadier with almost no pain. It lowers the psychological pressure of users very much and let people 
recover the test frequencies which recommended by HCPs.
A stylish, slim and ergonomic design is very convenient and user friendly.
Clear indication for depth penetration (numeric display): easy to read and adjust for users.
Important Lancing Device and Lancets Information
1.Lancet is for single use only.
2.Keep lancing device and lancets clean.
3.Use caution when removing the used lancet from the device and when disposing the used lancet.
The meter and lancing device are for single patient use.
Do NOT share them with anyone including family members.
Do NOT use on multiple patients.
Setting your Lancing Device
4. Performing a Blood Test
1A stylish, slim and ergonomic design is very 
convenient and user friendly.
2Big window to show the penetration depth with 
numeric display which is easy for the user to 
read.
3Big release button, comfortable and easy to 
operate.
4Patented feature of lancet ejection by one 
thumb pushing with only one hand operation.
5Patented safety switch design:
when the cap is closed, it allows only load but 
lock the function of lancet ejection. When cap 
is open, it allows lancet ejection but release the 
trigger automatically to prevent accidental 
pricking.
6Depth adjustable cap
7Release button
8Plunger
9Hub
AT Clear cap (optional)
AK Disposable lancet (optional)
1. Hold the depth adjustable 
cap in one hand and hold 
hub in the other hand, twist 
off the depth adjustable 
cap.
5. Select a depth of pene-
tration by rotating the top 
portion of the depth adjust-
able cap until the number 
matched to the window.
Settings are based on skin 
type.«1,2» are for
soft or thin skin. «3,4» are 
for average skin.
«5,6» are for thick or 
calloused skin.
2. Insert a new disposable 
lancet firmly into the lancet 
holder.
6. Hold the hub in one hand 
and push on the plunger in 
the other hand. The device 
will be cocked.
Release the plunger; it will 
go back to its original posi-
tion near the hub.
3. Twist off and set aside 
the protective cover of the 
disposable lancet.
4. Replace the depth 
adjustable cap.
The Lancing device is made by
MEDIFUN CORPORATION
No.8, Shuyi Rd., South Dist., Taichung 
City, 40241, Taiwan (R.O.C.)
1. Wash Your Hands and the Puncture Site:
Wash your hands in warm, soapy water. Rinse and dry completely. Warm your 
fingers to increase blood flow.
2. Insert Test Strip: 
Remove a new test strip from vial. Be sure to tightly replace vial cap after 
removing test strips. Insert a test strip with the contact bar end entering into the 
test strip slot first. Push the test strip as far as it will go without bending it. The 
meter turns on automatically.
*To track the position of test strip slot, press main button and the slot LED light will flashing.
3. Select and Lance a Puncture Site:
Hold the prepared lancing device firmly against the side of your fingertip. Press 
the release button.
NOTE: If you want to do alternative site testing, please refer to the «About Alter-
native Site Testing (AST)» section. Please consult your healthcare professional 
before obtaining blood from site other than your fingertip.
4. Obtain a Blood Sample:
Gently massage your finger or puncture site to obtain the required blood 
volume. To perform the test, you need only 0.5 μL of blood sample. Do not 
smear the blood sample. To obtain best accurate result, wipe off the first drop 
of blood and gently squeeze another drop of blood.
5. Apply Blood Sample:
When the meter shows the «» symbol, apply blood to the opening of the absor-
bent channel of the test strip where it meets the narrow channel. Blood will be 
drawn into the test strip. If the test strip confirmation window is full, you will hear 
a beep.
6. Read Your Result:
After the meter counts down from 5 to 1, your blood glucose test result appears 
along with the unit of measure, date and time.
7. Turn Off the Meter:
This blood glucose result is automatically stored in the meter memory. Turn the 
meter off by removing the test strip. Discard the used test strip carefully to avoid 
contamination.
8. Remove the Adjustable Comfort Tip:
After use, put the Protective Cap back onto the exposed needle of the lancet.
9. Dispose the used lancet correctly:
Slide the Lancet Ejector forward and dispose the used lancet in an approved 
container. Dispose the used lancet according to your country's safety regula-
tions. Replace the Lancing Device Cap.
1 2
3
4
5
6 7
9
8
AT
AK
1
5
2
6
3 4
AM
Incorrect Correct
GlucoTeq
Blood Glucose Monitoring System
EN Instruction Manual
Model No: BGM 200
ood
G
l
u
c
o
s
e
M
o
n
it
o
r
i
ng 
Sy
s
t
e
m
N
In
s
tr
u
c
ti
o
n
M
a
nu
a
l
M
odel No: B
G
M 200
Termékspecifikációk
| Márka: | Microlife | 
| Kategória: | Vércukormérő | 
| Modell: | GlucoTeq | 
Szüksége van segítségre?
Ha segítségre van szüksége Microlife GlucoTeq, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Vércukormérő Microlife
                        
                         10 Augusztus 2024
                        
                    
                                                            
                        
                         17 Július 2024
                        
                    
                                                            Útmutatók Vércukormérő
- Vércukormérő Medisana
 - Vércukormérő Accu-Chek
 - Vércukormérő IHealth
 - Vércukormérő Glucofix
 - Vércukormérő Rossmax
 - Vércukormérő AktivMed
 - Vércukormérő Beurer
 - Vércukormérő OneTouch
 - Vércukormérő GE
 - Vércukormérő Scala
 - Vércukormérő Sanofi
 - Vércukormérő HMM
 - Vércukormérő LifeScan
 - Vércukormérő Bioland
 - Vércukormérő Wellion
 
Legújabb útmutatók Vércukormérő
                        
                         31 December 2025
                        
                    
                                                            
                        
                         28 Augusztus 2024
                        
                    
                                                            
                        
                         28 Augusztus 2024
                        
                    
                                                            
                        
                         24 Augusztus 2024
                        
                    
                                                            
                        
                         24 Augusztus 2024
                        
                    
                                                            
                        
                         24 Augusztus 2024
                        
                    
                                                            
                        
                         24 Augusztus 2024
                        
                    
                                                            
                        
                         22 Augusztus 2024
                        
                    
                                                            
                        
                         21 Augusztus 2024
                        
                    
                                                            
                        
                         20 Augusztus 2024