Használati útmutató Optex FTN-AM

Oldalak 8 Engels nincs kategorizálva

Olvassa el ingyen online a(z) Optex FTN-AM használati útmutatóját, vagy töltse le PDF-ben. Az útmutatót 35 ember találta hasznosnak. Kérdése van a modellről? Tegyen fel kérdést

< CONTENTS >
< FEATURES >
Multilingual instructions
Visit to the Web site to find
valious language versions.
https://navi.optex.net/manual/08697/
EN-1
EN
INSTALLATION INSTRUCTIONS
fit
fit
FTN-STStandard model with 2 PIRs
FTN-AMFTN-ST with anti-masking
Compact outdoor
detector
Compact outdoor
detector
series
series
WIRED MODEL
•Compact design
•190° adjustable bracket
•Intelligent AND logic
•Digital anti-masking (AM model)
•Wall tamper (option)
1 INTRODUCTION
1-1 BEFORE INSTALLATION......................................1
1-2 PARTS IDENTIFICATION......................................2
1-3 DETECTION AREA................................................2
2 INSTALLATION
2-1 INSTALLATION......................................................3
3 WALK TEST
3-1 WALK TEST...........................................................5
4 DIP SWITCH SETTING
4-1 LED........................................................................5
4-2 ALARM OUTPUT...................................................5
4-3 PIR SENSITIVITY..................................................5
4-4 ANTI-MASKING......................................................6
5 OTHERS
5-1 WALL TAMPER (OPTION) CONNECTION...........6
5-2 EXAMPLE OF EOL WIRING..................................7
5-3 LED LIGHT PATTERN...........................................7
6 SPECIFICATIONS
6-1 SPECIFICATIONS..................................................8
6-2 DIMENSIONS.........................................................8
The check
mark indicates recommendation.
The nix
sign indicates prohibition.
Warning
Caution
Failure to follow the instructions provided with this indication and improper handling may cause
death or serious injury.
Failure to follow the instructions provided with this indication and improper handling may cause
injury and/or property damage.
Warning
CautionCaution
Do not remove the PCB.
ON
234
1
0.8 to 1.2 m
(2.6 to 3.9 ft.)
Parallel
Mounting height.
Tilt
Keep the detector parallel to the ground.
Consider the direction of the intruder,
for the setting of the detection area.
Do not touch the PCB except for the
DIP switch.
1
INTRODUCTION
1-1
BEFORE INSTALLATION

Értékelje ezt az útmutatót

Termékspecifikációk

Márka: Optex
Kategória: nincs kategorizálva
Modell: FTN-AM

Szüksége van segítségre?

Ha segítségre van szüksége Optex FTN-AM, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek