                        Oldal 1/8
                    
                    
                    
THE RECEIVER
The receiver comes in the format of a wristwatch.
•   You can wear it on your wrist:
EFFECTIVE RANGE
The  transmitter  and  receiver  will  start  transmitting  and 
receiving  signals  after  the  batteries  are  in  place.  When 
the battery is full, both  units can  be worn  or  mounted  up to           
76 cm (30 inches) apart.
If signals become unsteady:
•   Shorten the distance between the transmitter and  
  receiver.
•   Re-adjust the position of the transmitter.
•   Check the batteries. Replace them when necessary.
USE IN THE WATER
The SE200 is water-resistant up to 50 meters (164 feet).
 NOTE  Set the unit before  exposing it to excessive water. 
Pressing  the  keys  while  in  the  water  or  during  heavy 
rainstorms may cause water to enter the unit.
OPERATION
THE BACK LIGHT
Press   to turn on the backlight for five seconds.
OPERATING MODES
There are four operating modes:
                   Clock                                      Alarm
                 Stopwatch                            Heart Rate              
          Measurement
Press MODE to switch between:
•   Clock
•   Alarm
•   Stopwatch
Press  TIME  /    to  enter  HR  Measurement  mode.  Press 
TIME /  to return to the previous mode.
 NOTE  When no signals are received or the measurement 
is out of range for five minutes, the receiver will automatically 
return to the previous operating mode.
HEART RATE LIMITS
The heart rate limits help you determine if you are exercising 
within your training zone.
•   If you go above your limits (   ) will flash
•   If you go below your limits (   ) will flash
To set the heart rate limits:
1.  Press TIME /  to enter HR measurement mode.
2.  Press and hold   until “ MODE  ” appears.
3.  Press    SET MODE to choose the lower limit, then press 
  to confirm.
4.  Press   to choose the upper limit ( SET  ), then press  
 MODE to confirm.
  NOTE   The  upper limit  must exceed  the lower  limit. The 
transmitter will adjust the ranges automatically according to 
the data  entered.  You can  also activate the  heart rate  limit 
alert  function,  so  the  transmitter  will  emit  beeping  sound 
when the limits are exceeded.
To activate the heart rate limits alarm:
1.  Press TIME /   .
2.  Press and hold TIME /   .
TIME AND DATE
To set the time and date:
1.  Press   until Clock mode is displayed.MODE
2.  Press and hold MODE.
3.  Press SET to choose between 12 / 24-hour time.
4.  Press   to confirm.MODE
5.  Repeat steps 3 and 4 to set the:
  •   Hour
  •   Minutes
  •   Month
  •   Day
  •   Day of week
 TIP  Press and hold SET to rapidly change a value.
 NOTE  The date format for 12-hour display is MONTH-DAY 
while that for 24-hour display is DAY-MONTH.
To display the date:
Press SET in Clock mode.
 TIP   If  no key  is pressed  for ten  seconds, the  display will 
return to Clock mode.
To set the alarm:
1.  Press   to enter Alarm mode.MODE
ICON                HIGH / LOW ALARM
 On
No O Icon   ff 
                       Heart Rate Monitor
Model: SE200                                             
 USER MANUAL    
EN
INTRODUCTION
Thank you for selecting  the Oregon ScientificTM Heart Rate 
Monitor  (SE200).  The  SE200  is  a  very  useful  healthcare 
product  that  can  help  you  achieve  and  maintain  your 
optimum exercise zone  by  monitoring your  heart rate  while 
working out.
The  SE200  bundles  a  heart  rate  transmitter  and  receiver 
watch  complete  with  real-time  clock,  stopwatch,  and 
backlight functions.
KNOW YOUR DATA
To  help  achieve  the  maximum  health  benefits  from  your 
workout program, it is important to know your:
• Maximum heart rate (MHR) training zone
• Upper heart rate limit
• Lower heart rate limit
MHR  is  expressed  in  beats per  minute.  You can  get  your 
MHR  from  a  MHR  test,  or  you  can  estimate  it  using  the 
following formula:
220 - age = MHR
There  are  several  training  zones  that  that  are relevant  to 
a  fitness  program.  The  most  popular  zone  range  is  from 
50% to 80% of your  maximum heart rate. This is where you 
achieve cardiovascular benefits, burn fat, and become fitter. 
When programming your watch, the lower % of the zone you 
choose becomes your lower heart rate limit and the higher % 
becomes the upper heart rate limit.
The  upper  and  lower  heart  rate  limits  are  calculated  by 
multiplying  your  MHR  by  the  percentages  of  the  selected 
training zone.
For example:
A 40-year-old user training for basic health maintenance:
• His Upper Heart Rate Limit [220 - 40(age)] x 78% 
• His Lower Heart Rate Limit [220 - 40(age)] x 65% 
TRAINING ZONES
Always  warm  up  before  exercise  and  select  the  training 
zone  that best  suits  your  physique. Exercise  regularly,  20 
to 30  minutes  per session, three to four times a week for a 
healthier cardiovascular system.
There are three training zones, as described below:
 WARNING     Determining your individual  training zone  is 
a critical  step  in  the process  towards an  efficient and  safe 
training  program.  Please  consult  your  doctor  or  health 
professional  to  help  you  determine  your  maximum  heart 
rate, upper and lower limits, exercise frequency and duration 
appropriate for your age, condition and specific goals.
RECEIVER CONTROL BUTTONS
1.  SET BUTTON                                                         
 Changes values in Settings mode, turns the alarm on /  
  off  in Alarm mode, resets the stopwatch.
2.  MODE BUTTON                                                          
 Changes operating modes or press and hold to enter  
  Settings mode.
3.  ST / SP BUTTON                                                            
 Starts or stops the stopwatch.
4.    BUTTON                                                           
 Turns the EL backlight on for five seconds.
5.  TIME /   BUTTON                                                  
  Displays your heart rate or press and hold to activate  
  the high / low heart rate alert.
THE TRANSMITTER
The transmitter is used to count your heartbeat and transmit 
the data to the receiver. To put it on:
1.  Wet the conductive pads on the underside of the  
  transmitter with water or a conductive gel to help  
  establish solid contact.
2.  Strap the transmitter across the chest. Adjust the strap  
  until the transmitter sits snugly below the pectoral  
  muscles for an accurate heart rate signal.
 HINTS 
•   The position of the transmitter affects its performance.  
  Move the transmitter along the strap for the best  
  transmission. Avoid areas with dense chest hair.
•   In dry, cold climates, it takes the transmitter a while to  
  function steadily. This is normal, as the conductive pads  
  need a film of sweat to improve contact with the skin.
TRAINING ZONE
Health 
Maintenance 
Aerobic  
Exercise
Anaerobic 
Exercise
MHR % 
65 - 78%
65 - 85%
78 - 90%
DESCRIPTION
This is the lowest  training 
intensity level. It is good for 
beginners and those who 
want to strengthen their 
cardiovascular systems.
Increases strength and 
endurance. It works within 
the body’s oxygen intake 
capability, burns more 
calories, and can be 
maintained for a long period 
of time.
Generates speed and 
power. It works at or above 
the body’s oxygen intake 
capability, builds muscle, 
and cannot be maintained 
for a long period of time.
1 3
4
5
2
50%
60%
70%
80%
90%
100%
Moderate Activity
Weight Management
Aerobic Zone
Anaerobic Threshold Zone
Red Line Zone ( maximum capacity )
2.  Pres  until the hour digits flash.s and hold MODE
3.  Press SET MODE to adjust the hour, press   to confirm.
4.  Press   to adjust the minutes, press SET MODE to  
  confirm.
 TIP   If  no key  is pressed  for ten  seconds, the  display will 
return to Clock mode.
To activate or deactivate the alarm:
1.  Press   to enter Alarm mode.MODE
2.  Press   to turn the alarm on or off. A SET  will indicate  
  that the alarm has been activated.
 NOTE   When the  alarm  clock is activated, it will sound at 
the set time every day. Press any button to stop the alarm for 
that day. The alarm clock is still active and will set off  again 
the following day.
STOPWATCH
To use the stopwatch:
•   Press   repeatedly until you enter Stopwatch  MODE
  mode.
•   Press ST/SP to start the stopwatch.
•   Press ST/SP to stop the stopwatch.
•   Press and hold SET to reset.
 NOTE  Unless you stop the  , “   ” will blink in all stopwatch
modes to remind you that the stopwatch is still timing.
ADDITIONAL INFORMATION
BATTERY
The SE200 uses a CR2032 lithium battery for the transmitter 
and a  CR2032 for  the receiver. Both  are included  with the 
unit. When the receiver battery is running low, the low battery 
indicator   will light up on the watch display.
If  the  heart  rate  readings  become  erratic  or  stop,  your 
transmitter battery may need replacing.
To change the battery:
1.  Open the transmitter battery lid with a coin by turning 
  counterclockwise.
2.  Insert a new CR2032, 3V lithium battery.
3.  Replace the battery compartment door.
 NOTE  Take care  not  to touch  the two contacts otherwise 
the  battery  can  discharge.  If  you  are  unsure  about  the 
procedure consult your dealer.
ENERGY SAVING FEATURE
If the  watch receives  no  transmitter signal  after 5 minutes, 
the SE200 will switch back to the previous display mode.
SPECIFICATIONS
Real time clock:   12/24 hour with hour / minute / second
Stopwatch:   00:00:00 to 29:59:59 (hrs: min: sec)
Heart rate:   30 - 240 bpm
Upper limit:   80 - 240 bpm
Lower limit:   30 - 220 bpm
Power:   Watch 1 x CR2032 3V battery                        
    Chest belt 1 x CR2032 3V battery
Operating temp:   -10°C to +50°C (14°F to 122°F)
Storage temp:   -20°C to +60°C (-4°F to 140°F)
Water resistant:   Up to 50 meters (164 feet) without  
    pressing keys
SAFETY AND CARE
This product is designed to give you years of service if 
handled properly. Observe the following guidelines:
•   Clean the unit with a damp cloth and mild detergent.
•   Avoid dropping the unit.
•   Do not subject the main unit to extreme force, shock, or  
  fluctuations in temperature.
•   Do not tamper with the internal components.
•   Do not mix new and old batteries or batteries of different  
  types.
•   Remove the batteries if storing this product for a long  
  period of time.
•   Do not scratch the LCD display.
•   Do not make any changes or modifications to this  
  product. Unauthorized changes may void your right to  
  use the product.
•  Do not dispose this product as unsorted municipal  
  waste.  Collection of such waste separately for special  
  treatment is necessary.
•   The technical specifications for this product and the  
  contents of the user guide are subject to change without  
  notice.
•   Images not drawn to scale.
ABOUT OREGON SCIENTIFIC
Visit our website  (www.oregonscientific.com)  to  learn  more 
about  Oregon  Scientific  products  such as  digital cameras; 
MP3  players;  children’s  electronic  learning  products  and 
games; projection  clocks; health  and fitness  gear; weather 
stations;  and  digital  and  conference  phones.  The  website 
also  includes  contact  information  for  our  customer  care 
department  in  case  you  need  to  reach  us,  as  well  as 
frequently asked questions and customer downloads.
We hope  you will  find all  the information  you  need  on our 
website, however if you’re in the US and would like to contact 
the  Oregon  Scientific  Customer  Care  department  directly, 
please visit:
www2.oregonscientific.com/service/default.asp
OR
Call 1-800-853-8883. 
For international enquiries, please visit:
www2.oregonscientific.com/about/international.asp
EU-DECLARATION OF CONFORMITY SECTION
Hereby,  , declares  that  this  SmartHeart Oregon  Scientific
Heart  Rate  Monitor SE200   model   is  in  compliance  with 
EMC directive  89/336/CE. A copy  of the  signed and  dated 
Declaration  of  Conformity  is  available  on  request  via  our 
Oregon Scientific Customer Service.
RAIN 
SPLASHES
ETC
OK
SHOWERING
(WARM/
COOL
WATER
ONLY)
OK
LIGHT
SWIMMING
/ SHALLOW
WATER
OK
SHALLOW
DIVING/
SURFING/
WATER 
SPORTS
OK
SNORKELING
/ DEEP
WATER
DIVING
NO
50M /          
164 FEET
Termékspecifikációk
| Márka: | Oregon Scientific | 
| Kategória: | sportóra | 
| Modell: | SE200 | 
Szüksége van segítségre?
Ha segítségre van szüksége Oregon Scientific SE200, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók sportóra Oregon Scientific
                        
                         18 Augusztus 2024
                        
                    
                                                            
                        
                         15 Augusztus 2024
                        
                    
                                                            
                        
                         13 Augusztus 2024
                        
                    
                                                            
                        
                         8 Augusztus 2024
                        
                    
                                                            
                        
                         7 Augusztus 2024
                        
                    
                                                            
                        
                         6 Augusztus 2024
                        
                    
                                                            
                        
                         5 Augusztus 2024
                        
                    
                                                            
                        
                         5 Augusztus 2024
                        
                    
                                                            
                        
                         5 Augusztus 2024
                        
                    
                                                            
                        
                         5 Augusztus 2024
                        
                    
                                                            Útmutatók sportóra
- sportóra Lezyne
 - sportóra Krontaler
 - sportóra Amazfit
 - sportóra TFA
 - sportóra Acme
 - sportóra Xiaomi
 - sportóra Umidigi
 - sportóra Suunto
 - sportóra Asus
 - sportóra Pyle
 - sportóra Trevi
 - sportóra Cmee
 - sportóra Apple
 - sportóra Runtastic
 - sportóra Garmin
 
Legújabb útmutatók sportóra
                        
                         30 Március 2025
                        
                    
                                                            
                        
                         5 Január 2025
                        
                    
                                                            
                        
                         5 Január 2025
                        
                    
                                                            
                        
                         27 December 2024
                        
                    
                                                            
                        
                         27 December 2024
                        
                    
                                                            
                        
                         16 December 2024
                        
                    
                                                            
                        
                         16 December 2024
                        
                    
                                                            
                        
                         16 December 2024
                        
                    
                                                            
                        
                         16 December 2024
                        
                    
                                                            
                        
                         14 December 2024