Használati útmutató PCE Instruments PCE-USM
PCE Instruments
Mérőberendezések
PCE-USM
Olvassa el alább 📖 a magyar nyelvű használati útmutatót PCE Instruments PCE-USM (6 oldal) a Mérőberendezések kategóriában. Ezt az útmutatót 3 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.3 csillagra
Oldal 1/6

PCE-USM RS-232 - USB Logger
The logger enables the user to save the transmission data of the RS-232 interface to one or more
folders in txt format, along with the me and date. The logger can receive and retrieve data. This
means that with the right conguraon (consider pin assignment of the RS-232), the PCE-USM
adaptor can be connected with any RS- 2 interface to record the data. 23
With the scales PCE-LSM / PCE-LS / PCE-AB / PCE-ABZ / PCE-PM / PCE-TP / PCE-BDM / PCE-BT / PCE-
TB and PCE-SD Series, the PCE-USM can be plugged directly onto the RS-232 interface.
In case it is not possible to plug the adaptor directly onto the RS-232 interface, you have the
possibility to use an extension cable The standard edion comes with an external power supply. .
(12V / 100 mA mains adaptor in + / out -)

1. Connect the PCE-USM adaptor with the RS-232 interface. Then provide power supply and watch
the diodes at the PCE-USM storage adaptor. Both diodes will light up briey and the diode at the side
of the RS-232 interface should be lit now. If it does not, this normally means that the PCE-USM is not
connected to the power supply. Check the power supply If the diode at the side of the RS-232 .
interface ashes, a data transfer to the PCE-USM storage adaptor takes place.
2. Now insert the USB pen drive into the PCE-USM USB storage adaptor and watch the diodes. The
diode at the side of the RS-232 interface will ash briey and then light up permanently. During the
me the diode was ashing, a conguraon le was saved to the pen drive (see below).If the diode
at the side of the USB interface did not light up, this can mean that the USB pen drive was not
recognised or that it is full. Check the USB pen drive’s formang and, if necessary, try using another
pen drive. FAT12 / FAT16 and FAT32 formatng is possible Now try to transmit a few data to the .
PCE-USM adaptor via the RS-232 interface and watch the diodes of the PCE-USM adaptor. If the data
transmission was successful, the diode at the side of the RS-232 interface should ash rst, followed
by the diode at the side of the RS-232 interface. This ashing indicates: date received and transferred
to USB.

In case the data transmission was successfully completed, there will be two les on the USB pen
drive.
„CONFIG.TXT“ This is the conguraon le in which you can set individual parameters.
„LOG.TXT“ This is the le which contains your saved values.
The conguraon le “CONFIG.TXT“ looks as follows:
The values can easily be changed and thus adapted to your individual needs and dierent devices.
The values behind the can be changed On the right behind , you can see the possibilies of „=“ . „//“
what you can enter (allowed values).
Termékspecifikációk
Márka: | PCE Instruments |
Kategória: | Mérőberendezések |
Modell: | PCE-USM |
Szüksége van segítségre?
Ha segítségre van szüksége PCE Instruments PCE-USM, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Mérőberendezések PCE Instruments
29 Március 2025
28 Március 2025
28 Március 2025
28 Március 2025
28 Március 2025
28 Március 2025
28 Március 2025
28 Március 2025
28 Március 2025
28 Március 2025
Útmutatók Mérőberendezések
- Mérőberendezések Chauvin Arnoux
- Mérőberendezések Sekonic
- Mérőberendezések Steinberg
- Mérőberendezések Muller
- Mérőberendezések IFM
- Mérőberendezések Megger
- Mérőberendezések CESYS
- Mérőberendezések Extech
- Mérőberendezések Elgato
- Mérőberendezések Dahua Technology
- Mérőberendezések HT Instruments
- Mérőberendezések Uni-T
- Mérőberendezések RK Technology
- Mérőberendezések Clean Air Optima
- Mérőberendezések Maximum
Legújabb útmutatók Mérőberendezések
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025
3 Április 2025