Before the measurement, please make sure the selected
button accords with the measured position.
TH52Z Multi-function Infrared Thermometer
Functions
Real Time Clock
The real time clock will be recorded with the memory function and help you to recognize each
measurement result. (It includes the 12/24 Format_Hour_Minutes_Date.)
Please see the “Real time clock setting” section to learn how to setup the time in the first use.
Room Temperature
Suitable ambient temperature is important for the baby and patient, the thermometer always help you
recognize the room temperature.
Setting “Real time clock” first to enable this function. After power off, room temperature will be shown
on the screen with icon.
Please see the “Use of the thermometer” section to learn how to get the correct room temperature.
Forehead / Ear
Temperature
The thermometer has been designed for practical use. It’s not meant to replace a visit to the doctor.
Please also remember to compare the measurement result to your regular body temperature. Please
consult with doctor if you have health concerns.
Please see the “Use of the thermometer” section to learn how to measure the body temperature.
Scan Mode
The Scan mode shows the actual, unadjusted surface temperatures, which is different from the body
temperature. It can help you to monitor if the object temperature is suitable for the baby or patient, for
example the baby’s milk.
Please see the “Use of the thermometer” section to learn how to measure the object temperature.
Stopwatch The thermometer built the stopwatch function to help you to monitor the heartbeat
since heartbeat is one
of the healthy indexes for people.
Please see the “Use of the Stopwatch” section to learn how to measure the heartbeat result.
Fever Alarm If thermometer detects a body temperature > 37.5°C, there will be a long beep sound followed by three
short beep sound to warn the user for potential fever.
Zone Indicator Under ear or forehead mode, if thermometer detects a body temperature< 37.5°C, there will be " Green"
light signal; if temperature > = 37.5°C and < 38.0°C, there will be" Yellow" light signal; if temperature
> =38.0°C, there will be" Red" light signal.
Memory Locations There are total 9 sets memories for body measurement. Each memory also records the measurement
date/time/mode icon and site location..
When in power on, Press the “ON/MEM” button to see the temperature stored with icon.
°C / °F Switch In “power off” mode (The LCD only shows the date, time and room temperature). Press and hold the
“FOREHEAD” button, then immediately press and release the “ON/MEM”
button. After 3 seconds, icon
“°C” will be switched to icon “°F”. (You may use the same way to switch back to “°C”)
Real time clock setting
1. Power on: Press the “ON/MEM” button. The thermometer is ready for use after hearing two beep sounds.
2. Press and hold the “ON/MEM” button for 5sec. When you see the Set icon starts flashing, it indicates that you are in the setting screen.(see the following figure.)
3. Press the “FOREHEAD” button to make the “24” icon flash. This indicates that you are in the 12/24-hour setting screen. Press the “FOREHEAD” button to set
12/24-hour Format from “24”(24-hour) to “12”(12-hour).
4. Press “ON/MEM” button to move the flashing in the sequence shown below to select our settings:
hourminutesyearmonthdayleave the setting screen.
5. While the hour, minutes, year, month, day setting is flashing, use “FOREHEAD” button to change it.
Use of the thermometer
1. Always make sure the probe is clean, and without damage.
2. Power on: Press “ON/MEM” button.(see figure 1)
3. Mode selection:
3.1 Ear mode :Press the “Ear” button, you can get the body temperature by ear measurement after
hearing two beep sounds. (see figure 1)
Specifications Temperature measurement range:
Forehead / Ear mode: 34~42.2°C (93.2~108°F), Scan mode: -22~80°C (-7.6~176°F)
Operating temperature range: 10~40°C (50~104°F)
Storage temperature range: It should be stored at room temperature between -20~+50°C,
RH≦85%
Transportation temperature shall be less than 70°C, RH≦95%
Comply with ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part
5:Performance of infra-red ear thermometers(with maximum device),
IEC/EN60601-1-2(EMC),IEC/EN60601-1(Safety) standards.
Accuracy:
For ear mode: +/-0.2°C (0.4°F) during 35.5~42°C (95.9~107.6°F),
+/-0.3°C (0.5°F) for other range.
For forehead mode: +/-0.2°C (0.4°F) during 36~39°C (96.8~102°F),
+/-0.3°C (0.5°F) for other range.
For scan mode: +/-0.3°C (0.5°F) during 22~42.2°C (71.6~108°F),
others +/-4% or +/-2°C (4°F) whichever is greater.
Fever alarm & Memory locations under “Ear/Forehead mode” (with each measurement
date/time/mode icon)
3 color LED Fever Indicator
Real time clock, °C / °F Switch mode
Battery: one lithium cell battery (CR2032 *1pcs)
This thermometer converts the ear/forehead temperature to display its “oral equivalent.”
There is no gender and age limitation for using infrared thermometer.
This is not an AP or APG product.
Figure 1 Figure2 Figure 3 Figure
4

3.2 Forehead mode: Press the “FOREHEAD” button, you can get the body temperature by forehead measurement after hearing two beep sounds. (see figure 2)
3.3 Scan Mode: Press and hold the “ON/MEM” button, and press the “FOREHEAD” button one
time, you can see the icon on your LCD display(see figure 3). In this mode,
press the “FOREHEAD” button to get the target surface temperature.
3.4 Stopwatch: Press and hold the “ON/MEM” button, and press the “FOREHEAD” button twice,
you can see the icon on your LCD display(see figure 4). In this mode, press the
“FOREHEAD” button to count by 0.01sec to 3 minutes.
4. Temperature taking:
4.1 Ear temperature measuring, points for attention:
Remarks: a. It is recommended that you measure 3 times with the same ear. If the 3 measurements are different, select the highest temperature.
b. To avoid the risk of cross contamination, please clean the probe according to “Care and cleaning” section after each use.
4.1.1 Gently pull the ear back to straighten the ear canal (Fig.4.1.1) and snugly position the probe into the ear canal, aiming towards the
membrane of the eardrum to obtain an accurate reading (Fig.4.1.2).
4.1.2 Press and hold the “Ear” button
until you hear a beep sound. Remove the probe from ear and read the temperature measurement
on the LCD.
c. The different temperature varies in healthy persons between different parts of the body can be between 0.2~1°C
d. Clinical repeatability: 0.23°C (<1 year old),0.22°C (1~5 years old),0.21°C (>5 years old)
4.2 Forehead temperature measuring, points for attention:
Remarks: a. Forehead temperature is displayed in oral mode. This mode converts the forehead temperature to display its “oral-equivalent” Value.
b. Before the measurement, please stay in a stable environment for 5mins and avoid exercise, bath for 30mins.
c. Remember to keep the temple area clean and away from sweat, cosmetics and scar while taking temperature.
4.2.1 The temporal artery is connected to the heart via the carotid artery. It is designed to measure the skin surface around
temporal artery, a major artery of the head (Fig.4.2.1).
4.2.2 Attach the thermometer to the required measurement location on the forehead (Fig. 4.2.2). (You can choose left or
right temple.)
4.2.3 Press the “FOREHEAD ” button, and gently scan around the temple area (Fig. 4.2.3). While scanning, you will hear a
beep sound, which indicates you the newest measurement is taking place. Measurement has been completed after
two short beeps are heard and the forehead icon stops flashing. The time consuming for measurement might be
between 5~8 sec (up to 30sec). It depends on how much time the device needs to get the correct forehead
temperature.
4.3 Measuring temperature under Scan mode:
4.3.1 When you press the “FOREHEAD” button, you will get the real time temperature immediately. If you press and hold the “FOREHEAD” button, the reading of
measurement will be continuous updated.
4.3.2 Applications include temperature measurements for Water, Milk, Cloth, Skin or other object.
* Note: This mode shows the actual, unadjusted surface temperatures, which is different from the body temperature.
4.4 Get the room temperature
4.4.1 Setting “Real time clock” first to enable this function. After power off, room temperature will be shown on the screen with icon.
4.4.2 For room temperature, the thermometer should be placed on the table and avoid the direct sunshine or air conditioner flow on.
4.4.3 The room temperature can be reference after 15min later.
5. After Measurement:
5.1 Power off: Device will automatically shut off if left idle for more than 1 minute to extend battery life. The LCD will only show the date, time and room temperature.
5.2 Clean the probe after each use to ensure an accurate reading and avoid cross contamination. (See the section of Care and Cleaning for details.)
5.3 Remember to put on the Probe Cap when not in use.
Use of the Stopwatch
1. Press and hold the “ON/MEM” button, and press the “FOREHEAD” button twice for “stopwatch” mode.
2. For start or stop counting, press the “FOREHEAD” button; for reset counting, press the “ON/MEM” button.
3. Press and hold the “ON/MEM” button, and press the “FOREHEAD” button to enter the forehead mode.
4. How to measure the heartbeat? If you count out the number of beating is 18 in 15sec, then you can calculate the heartbeat of patient is 72 times in 1min.
Figure 4.1.1 Figure 4.1.2
Figure 4.2.3 Figure 4.2.2 Figure 4.2.1

Ref No.:022011
Important Notes
Care and cleaning
The probe is the most delicate part of the thermometer. Use with care when cleaning the lens to avoid damage.
a. After the measurement, please use the cotton swab with the Alcohol (70% concentration) to clean the inside of the probe,
including lens and metal parts.
b. Allow the probe to fully dry for at least 1 minute.
c. Storage temperature range: It should be stored at room temperature between -20~+50°C,
RH≦85%
d .Keep the unit dry and away from any liquids and direct sunlight.
e. The Probe should not be submerged into liquids.
* Note: Please check the device if damaged once it falls. If you can’t make sure of it ,please send the
complete device to the nearest retailer for recalibration.
Holding the thermometer too long may cause a higher ambient temperature reading of the probe.
This could make the body temperature measurement lower than usual.
Battery replacement
○
1 Open the battery cover: Insert a pointed object, such as a pen, into battery cover pick hole.
At the same time, use thumb to push battery cover out.
○
2 Hold the device and flip the battery out with a small screwdriver
○
3 Insert the new battery under the metal hook on the left side and press the right side of the battery
down until you hear a click.
○
4 Replace the battery cover
Keep the battery away from children. (This device is supplied with one lithium cell (CR2032x1).)
The positive (+) side up and the negative (-) side pointed down.
Trouble shooting:
Error Message Problem Solution
Error 5~9, the system is not functioning properly. Unload the battery, wait for 1 minute and repower it. If the message
reappears, contact the retailer for service.
Measurement before device stabilization. Wait until all the icons stops flashing.
The device showing a rapid ambient temperature change.
The ambient temperature is not within the range between 10oC and 40oC (50oF
~104oF).
Allow the thermometer to rest in a room for at least 30 minutes at room
temperature: 10oC and 40oC (50oF ~104oF).
(1) In Ear/Forehead mode: Temperature taken is higher than +42.2oC (108°F)
(2) In Scan mode: Temperature taken is higher than +80oC (176°F)
(1) In Ear/Forehead mode: Temperature taken is lower than +34oC (93.2°F)
(2) In Scan mode: Temperature taken is lower than –22oC (-7.6°F)
Please select the target within specifications. If a malfunction still exists,
please contact the nearest retailer.
Device cannot be powered on to the ready stage. Change with a new battery.
Warranty:
Warranty :12 months
Manufacture Date:as the serial number( please open the battery cover, it is shown on the inside of the device.)
Ex.SN:E912A000001, the first “E” is External, the second number “9” is the manufacture year 2009, the third and the fourth number “12” is the manufacture month, the
others is the serial number.
Note: Suggest that the device is performed the re-test for accuracy after 3 years. Please send the complete device to the dealers or nearest service address.
However, if this device is used according to the operation instruction, periodic re-calibration is not required.
Please read the instructions for use BF type applied part
Radiant Innovation Inc.
Http://www.radiantek.com.tw
Add: 1F, No.3, Industrial East 9th Road,
Science-Based Industrial Park, HsinChu, Taiwan 300.
Medical Technology Promedt Consulting GmbH
Add: Altenhofstrasse 80, D-66386 St. Ingbert, Germany
Termékspecifikációk
Márka: | Radiant |
Kategória: | hőmérő |
Modell: | TH52Z |
Szüksége van segítségre?
Ha segítségre van szüksége Radiant TH52Z, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók hőmérő Radiant

24 Augusztus 2024
Útmutatók hőmérő
- hőmérő PeakTech
- hőmérő Braun
- hőmérő Nedis
- hőmérő Milwaukee
- hőmérő Philips
- hőmérő Oregon Scientific
- hőmérő SilverCrest
- hőmérő Bosch
- hőmérő AEG
- hőmérő Emerio
- hőmérő Nokia
- hőmérő Omron
- hőmérő Bartscher
- hőmérő Tefal
- hőmérő Auriol
- hőmérő Emos
- hőmérő Voltcraft
- hőmérő Motorola
- hőmérő Beurer
- hőmérő Medisana
- hőmérő Omega
- hőmérő Thomson
- hőmérő Esperanza
- hőmérő Scala
- hőmérő Cuisinart
- hőmérő Speco Technologies
- hőmérő Owon
- hőmérő Duronic
- hőmérő Clatronic
- hőmérő Hama
- hőmérő Sanitas
- hőmérő Sencor
- hőmérő Techno Line
- hőmérő Innoliving
- hőmérő Citizen
- hőmérő TurboTronic
- hőmérő Inventum
- hőmérő Telefunken
- hőmérő Bresser
- hőmérő Klein Tools
- hőmérő Chauvin Arnoux
- hőmérő Microlife
- hőmérő Denver
- hőmérő Trevi
- hőmérő Beha-Amprobe
- hőmérő Elta
- hőmérő Orbegozo
- hőmérő Respekta
- hőmérő Joy-It
- hőmérő Extech
- hőmérő TrueLife
- hőmérő Testo
- hőmérő Powerfix
- hőmérő TriStar
- hőmérő ProfiCare
- hőmérő BeSafe
- hőmérő Alecto
- hőmérő Velleman
- hőmérő Terraillon
- hőmérő TFA
- hőmérő Lanaform
- hőmérő Leifheit
- hőmérő Melissa
- hőmérő Trotec
- hőmérő Eurochron
- hőmérő Pancontrol
- hőmérő Elro
- hőmérő InfiRay
- hőmérő Fluke
- hőmérő Uni-T
- hőmérő Olympia
- hőmérő Rossmax
- hőmérő ZKTeco
- hőmérő La Crosse Technology
- hőmérő A&D
- hőmérő Konig
- hőmérő GlobalTronics
- hőmérő Pyle
- hőmérő Testboy
- hőmérő Laica
- hőmérő IFM
- hőmérő Greisinger
- hőmérő Kyoritsu
- hőmérő Stanley
- hőmérő Vemer
- hőmérő Silverline
- hőmérő Taylor
- hőmérő Cotech
- hőmérő Ebro
- hőmérő Thermoval
- hőmérő Arendo
- hőmérő Beper
- hőmérő Optex
- hőmérő SereneLife
- hőmérő Salter
- hőmérő Topcom
- hőmérő Weber
- hőmérő Comelec
- hőmérő Homedics
- hőmérő Orava
- hőmérő Laserliner
- hőmérő TensCare
- hőmérő Hazet
- hőmérő Zeiss
- hőmérő Fysic
- hőmérő Quigg
- hőmérő Ade
- hőmérő AnD
- hőmérő Amprobe
- hőmérő ATN
- hőmérő Aponorm
- hőmérő Kruidvat
- hőmérő Easypix
- hőmérő Cresta
- hőmérő Marquant
- hőmérő Perel
- hőmérő Flir
- hőmérő AcuRite
- hőmérő Summer
- hőmérő Technoline
- hőmérő Vicks
- hőmérő Welch Allyn
- hőmérő BabyOno
- hőmérő Safety 1st
- hőmérő Inkbird
- hőmérő Boso
- hőmérő Clas Ohlson
- hőmérő Turbotech
- hőmérő Luvion
- hőmérő Irox
- hőmérő Reer
- hőmérő Waeco
- hőmérő Miniland
- hőmérő CaterChef
- hőmérő Etekcity
- hőmérő Ecomed
- hőmérő Save Demp
- hőmérő Comark
- hőmérő Fora
- hőmérő AGM
- hőmérő Beaba
- hőmérő Grado
- hőmérő La Crosse
- hőmérő Medel
- hőmérő Geratherm
- hőmérő Hartig And Helling
- hőmérő Pacom
- hőmérő Westfalia
- hőmérő Bioland
- hőmérő Global Tronics
- hőmérő Levita
- hőmérő Blue Circle Medical
- hőmérő Kerbl
- hőmérő Okoia
- hőmérő Silvergear
- hőmérő Uebe
- hőmérő Dittmann
- hőmérő Sensitec
- hőmérő TFA Dostmann
- hőmérő CDN
- hőmérő Emga
- hőmérő Hartmann
- hőmérő Premiumful
- hőmérő MostEssential
- hőmérő VDH
- hőmérő Telesystem
- hőmérő General
- hőmérő Arya
- hőmérő RK Technology
- hőmérő Mobi
- hőmérő TQC
- hőmérő Bintoi
- hőmérő Veroval
- hőmérő Jumper
- hőmérő Elem6
- hőmérő Pasha
- hőmérő Innovo
- hőmérő Delta Ohm
- hőmérő Guide
- hőmérő Neno
- hőmérő PCE Instruments
- hőmérő Knikker
- hőmérő FlinQ
- hőmérő AvaTemp
- hőmérő EasyLife
- hőmérő Alter
- hőmérő Unknown
- hőmérő Yummly
- hőmérő Eks
- hőmérő Gima
- hőmérő Aspen
- hőmérő Salva Tec
- hőmérő Kuchenprofi
- hőmérő WBTT
- hőmérő Welby
- hőmérő Prologue
- hőmérő ClimeMET
- hőmérő Bearware
- hőmérő Senseca
- hőmérő A&D Medical
- hőmérő Alphamed
Legújabb útmutatók hőmérő

10 Április 2025

8 Április 2025

7 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

2 Április 2025

2 Április 2025

1 Április 2025