Használati útmutató Valcom VP-6124-UPS
Valcom
Akkumulátor töltő
VP-6124-UPS
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Valcom VP-6124-UPS (3 oldal) a Akkumulátor töltő kategóriában. Ezt az útmutatót 14 ember találta hasznosnak és 7.5 felhasználó értékelte átlagosan 5.0 csillagra
Oldal 1/3

VSP VP- - -6124 UPS
Issue 3
1947271
VP- -6124 UPS
ADD ON OPTION FOR THE VP- - -6124/VP 6124 E
POWER SUPPLY
INTRODUCTION
The VP- -6124 UPS is an optional unit that allows the
VP- - -6124/VP 6124 E to supply power during a power
outage.
The VP- - - -6124 UPS is comprised of a VP 6124 UPS
(Charger) and a VBB-1424 (Battery Enclosure). The
VP- - -6124 UPS connects to the VP 6124 Power Supply
(To receive power to charge the batteries).
Listed below are specifications and recommendations
for power sources as well as precautionary
instructions.
UPS Float Standby Charging
Charging Voltage: 27.6 Volts (13.8 Volts per battery)
Current Limit: 900mA charging
100mA at 27 Volts final charge
Fusing: 1 Amp auto-reset polyswitch
6 Amps accidental reverse battery polyswitch
Time Required to Recharge Battery
7AH Battery: 14 hours
Length of Time Battery Will Provide
Power
• With four 7AH 12V batteries for 14AH total
3 Amps load draw: 3 hours run time
6 Amps full load: 1.5 hours run time
Use of batteries greater than 7AH is not
recommended since 90% of all power outages are less
than an hour in length and the time to evacuate a
building is less than an hour.
NOTE: To insure trouble- -free UPS back up
operation, five years batteries must be replaced five
years from the date of manufacturing.
DIMENSIONS/WEIGHT
• 10.30"H x 3.50"W x 2.25"D
• (26.16cm H x 8.89cm W x 5.72cm D)
2.90 lbs. (1.32 kg)
INSTALLATION
The VP- -6124 UPS (Charger) is designed for wall
mounting only. Screw the mounting plate to the wall
near the VP- - -6124/VP 6124 E and position the
VP- -6124 UPS onto the mounting plate.
Attach the UPS unit securely to the bracket lip using
the 6- -32 x 3/8" long Phillips head self tapping screw
supplied. Place the VBB-1424 on the floor within six
feet of the unit.
CONNECTIONS
• Disconnect AC power from the power supply.
• Remove plug button from the VP- - -6124/VP 6124 E.
• Remove wire access cover from the
VP- - -6124/VP 6124 E.
• Using the cable designated by the tag labeled
Valcom P/N WA-784 with four positions
connector and attached to VP- -6124 UPS
(Charger), place the Molex connector through the
hole on the power supply and connect the
charger to the Molex input connector on the
VP-6124 Power Supply.
• Snap strain relief into place.
• Replace wire access cover on the
VP- - -6124/VP 6124 E.
• Remove cover from Battery Backup.
• Push cable labeled Valcom P/N WA-783 with two
positions connector through the hole on the
battery enclosure and snap strain relief into
place.
Termékspecifikációk
| Márka: | Valcom |
| Kategória: | Akkumulátor töltő |
| Modell: | VP-6124-UPS |
Szüksége van segítségre?
Ha segítségre van szüksége Valcom VP-6124-UPS, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Akkumulátor töltő Valcom
5 Szeptember 2024
Útmutatók Akkumulátor töltő
- Akkumulátor töltő Speed & Go
- Akkumulátor töltő Lockncharge
- Akkumulátor töltő Davis
- Akkumulátor töltő Ultimate Speed
- Akkumulátor töltő Perel
- Akkumulátor töltő Interphone-Cellularline
- Akkumulátor töltő PACO
- Akkumulátor töltő DJI
- Akkumulátor töltő V7
- Akkumulátor töltő ABB
- Akkumulátor töltő Emtop
- Akkumulátor töltő StarTech.com