Quick Reference Guide

SlimBANK T18 USB QRG EN
2
About This
Guide
The SlimBANK T18 USB Quick Reference Guide (QRG) has basic product
information such as mounting, menu options, and DMX values. Download the User
Manual from www.chauvetlighting.com for more details.
Disclaimer
The information and specifications here are subject to change without notice. Chauvet
reserves to right to revise or reissue this QRG.
Safety Notes
These Safety Notes include important information about product mounting, use, and
maintenance.
•
ONLY connect this product to a grounded and protected circuit.
• DISCONNECT from power before cleaning or replacing the fuse.
• DO NOT look at the light source when the product is on.
• Make sure the power cord is not crimped or damaged.
• Never disconnect this product from power by pulling on the cord.
• When mounting this product overhead, ALWAYS use a safety cable.
• DO NOT allow flammable materials close to the product when it is operating.
• DO NOT touch the product’s housing when it is on because it will be hot.
• DO NOT operate this product if the housing, lenses, or cables appear damaged.
• The voltage of the outlet to which you are connecting this product must be within
the range stated on the decal or rear panel of the product.
• This product is for
indoor use only! (IP20) To prevent risk of fire or shock, do not
expose this product to rain or moisture.
• Always mount this product in a location with adequate ventilation, at least 20 in
(50 cm) from adjacent surfaces.
• Be sure that no ventilation slots on the unit’s housing are blocked.
• Never connect this product to a dimmer or rheostat.
• Replace the fuse with the same type and rating.
• ONLY carry this product by the hanging/mounting brackets.
• The maximum ambient temperature is 104 °F (40 °C). Do not operate this
product at higher temperatures.
• In the event of a serious operating problem, stop using immediately.
• DO NOT open this product. It contains no user-serviceable parts.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-
use completely disconnect the product from power via breaker or by unplugging
it.
Contact
Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux, contact your
distributor to request support or return a product. Visit www.chauvetlighting.com
for
contact information.
What Is
I
ncluded
• SlimBANK T18 USB
• Barn Doors
• Power Cord
• Warranty Card
• Quick Reference Guide
To Begin
Unpack your SlimBANK T18 USB and make sure you have received all parts in good
condition. If the box or contents appear damaged, notify the carrier immediately, not
Chauvet.

SlimBANK T18 USB QRG EN
3
Product
Description
The SlimBANK T18 USB is a tri-color LED panel. Removable barn doors direct light
where needed. Built-
in infrared technology offers easily controllable static colors and
automated programs with the optional IRC-
6 remote. DMX control wirelessly with the
convenient built in D-Fi USB port. Eighteen high-power, tri-
color LEDs nearly
eliminate multicolored shadows and the smooth and even output makes it perfect
for
frontlight applications.
Product
Overview
WARNING! DO NOT plug anything other than a D-
Fi USB into the USB port.
Doing so may cause damage to the product.
AC Power
This product has an auto-ranging power supply that can work with an input voltage
range of 100 to 240 VAC, 50/60 Hz.
To eliminate wear and improve its lifespan, during periods of non-
use completely
disconnect from power via breaker or by unplugging it.
Power Linking
For the maximum number of SlimBANK T18 USB products that you can power link at
each voltage, see the User Manual or the sticker on the product.
Fuse
Replacement
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the safety cap out of the housing.
4.
Remove the blown fuse from the clip on the front of the safety cap and replace with
a fuse of the exact same type and rating.
5. Re-insert the fuse holder and reconnect power.
Power In
Fuse Holder
LED Display
DMX In/Out
Microphone
D-Fi USB Port
Menu Buttons
Power Out
Safety Cable
Pass-Through
Mounting Brackets
Bracket
Adjustment
Knob
Termékspecifikációk
Márka: | Chauvet |
Kategória: | DJ Gear |
Modell: | SlimBANK T18 USB |
Szüksége van segítségre?
Ha segítségre van szüksége Chauvet SlimBANK T18 USB, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók DJ Gear Chauvet
4 Szeptember 2024
30 Augusztus 2024
30 Augusztus 2024
30 Augusztus 2024
30 Augusztus 2024
30 Augusztus 2024
30 Augusztus 2024
Útmutatók DJ Gear
- DJ Gear Technaxx
- DJ Gear Gemini
- DJ Gear Vonyx
- DJ Gear Power Dynamics
- DJ Gear Audio-Technica
- DJ Gear IK Multimedia
- DJ Gear Korg
- DJ Gear Cambridge
- DJ Gear SilverCrest
- DJ Gear American DJ
- DJ Gear Native Instruments
- DJ Gear ION
- DJ Gear Auna
- DJ Gear Thorens
- DJ Gear Eurolite
Legújabb útmutatók DJ Gear
15 Március 2025
12 Január 2025
12 Január 2025
8 Január 2025
6 Január 2025
6 Január 2025
6 Január 2025
6 Január 2025
6 Január 2025
6 Január 2025