User Manual s
K01-0000 - 855 00
Thank you for selecng the CyberPower UPS product. This UPS is designed to provide unsurpassed power protecon, operaon and
performance during the lifeme of the product. Please take a few minutes to register your product by vising:
CyberPowerSystems.com/registration. Registraon ceres your product's warranty, conrms your ownership in the event of a
product loss or the and entles you to free technical support.
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instrucons. Please read and follow all instrucons carefully during installaon and operaon of
the unit. Read this manual thoroughly before aempng to unpack, install, or operate your UPS.
CAUTION! To prevent the risk of re or electric shock, install in a temperature and humidity controlled indoor area ee of fr
conducve contaminants. (Please see specicaons for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside.
CAUTION! Hazardous live parts inside can be energized by the baery even when the AC input power is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protecon. Do not plug into an outlet
that is not grounded. If you need to de-energize this equipment, turn o and unplug the unit.
CAUTION! To avoid electric shock, turn o the unit and unplug it from the AC power source before installing a computer component.
CAUTION! Not for use in a computer room as dened in the Standard for the Protecon of Electronic Computer/Data Processing
Equipment, ANSI/NFPA 75.
CAUTION! To reduce the risk of re, connect only to a circuit provided with 20 amperes maximum branch circuit over current
protecon in accordance with the Naonal Electric Code, ANSI/NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
applicaons. use in any circumstance that would aect operaon and safety of life support equipment, any medical DO NOT
applicaons or paent care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium.
Condensaon from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of re or electric shock, do not use the unit on any
transportaon such as airplanes or ship. Th eect of shock or vibraon caused during transit and the damp environment can cause e
the unit to short out.
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(a) UPS unit (b) Users manual USB A+B type cable(c)
*PowerPanel® Personal soware is available as a free download at:CyberPowerSystems.com/products/soware.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into t UPS y (450VA/260W for EC450G, he does not exceed the UPS unit’s rated capacit
550VA/330W for EC550G, 750VA/450W for EC750G, 650VA/ 0W for EC650LCD, and 850VA/510W for EC850LCD). If the rated 39
capacies of the unit are exceeded, an overload condion may occur and cause the UPS unit to shut down or the circuit breaker to
trip.
2. There are many factors that can aect the amount of power that your electronic equipment ll require. For opmal system wi
performance keep the load below 80% of the unit’s rated capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, aer receiving
a new UPS, to ensure the baerys maximum charge capacity, it is
recommended that you charge the baery for at least 8 hours. Your UPS is
equipped with an auto-charge feature. When the UPS is plugged into an AC
outlet, the baery will automacally charge whether the UPS is turned on or
turned o.
Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment. Th rst me you turn e
the UPS on, you will need to have it connected to AC power or it will not power up.
2. With the UPS unit turned o and unplugged, connect your computer, monitor, and any other peripherals requiring baery backup
into the baery power supplied outlets. Plug the other peripheral equipment (e.g. printer, scanner, speakers, etc.) into the full-time
surge protecon outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other
large electrical device into the Baery and Surge Protected Outlets“ ”. The power demands of these devices will overload and
possibly damage the unit.
3. Plug the UPS into a 2 pole, 3 wire ground receptacle (wall outlet). Make sure the wall branch outlet is ed
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air
condioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips,
and surge strips in conjuncon with the UPS unit.
4. Press the power switch to turn the unit on. The Power On indicator light will illuminate green twice. and the unit will “beep”
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS o and
unplug at least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and
then turn the UPS on.
6. To maintain opmal battery charge, leave the UPS plugged into an AC outlet at all mes.
7. To store UPS for an extended period of me, cover it and store with the baery fully charged. While in storage, recharge the the
baery every three months to ensure opmal baery life.
8. Ensure the wall outlet and UPS are located near the equipment being aached for proper accessibility.
DESCRIPTION
1. Battery and Surge Protected Outlets
The unit has baery powered/surge suppression outlets to ensure temporary uninterrupted operaon of your equipment during a
power failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large
electrical device into the Baery and Surge Protected Outlets.“ ” The power demands of these devices will overload and
possibly damage the unit.)
2. Full-Time Surge Protecon Outlets / ECO Controlled Outlets
The unit has surge suppression outlets to provide surge and line noise protecon. Three of the surge-only outlets are also ECO
controlled outlets.
3. ECO Indicator
ECO Indicator shows the condion of ECO funcon. For more informaon, refer to secon. ECO Funcon Setup
4. Power On Indicator (green)
This LED is illuminated when the ulity power is normal and the UPS outlets are providing power, free of surges and spikes.
5. Power Switch
To turn the UPS , press the power buon for approximately 2 seconds - you will hear a constant tone (1 second) - and release ON
aer a short beep.
To turn the UPS , press the power buon for approximately 2 seconds - you will hear a constant tone (1 second) - and release OFF
aer two short beeps.
Alarm seng: The audible alarm can be turned by double click the POWER buon. The default seng is for the Alarm O or On
On. To turn the Alarm O, double click the buon. You will hear two short beeps when the Alarm is turned o . To turn the Alarm ff
back On, double click the buon. You will hear a single short beep when the Alarm is turned on. *When the Alarm is turned O,
there will be no audible nocaon when the UPS reaches a low baery state.
6. Mode Switch (EC650LCD and EC850LCD only)
Press the Mode Switch for approximately 3 seconds to enter setup mode to select four funcons: Ulity High Voltage Range,
Ulity Low Voltage Range ECO ON/OFF and LCD sleep ON/OFF. When a function is selected, press Mode Switch for 3 seconds to , ,
view opons. When an opon is selected, wait for 8 seconds for the seng to be conrmed. Aer the seng has been
conrmed the LCD screen will leave setup mode and go back to status display. If there is no acon for 8 seconds during setup, the
LCD will also leave setup mode and go back to the status display.
a. Ulity High Voltage Range: Adjust the value of high voltage range.
b. Ulity Low Voltage Range: Adjust the value of low voltage range.
c. ECO: Eon/EoF (ON/OFF) Turn on or turn off ECO funcon. more informaon, refer to section. : For ECO Funcon Setup
d. LCD L1/L0 (ON/OFF): :
* When LCD is set to L1, LCD will be always ON When LCD is set to , LCD will dim if untouched for 1 minute. . L0
* In baery mode, LCD is always on regardless if the setng is L1 or L0.
ECO Buon (EC450G, EC550G, and EC750G only)
Press ECO buon for 3 seconds to turn on or turn o ECO funcon in line mode.
7. Circuit Breaker
Located on the side of the UPS, the circuit breaker serves to provide overload and fault protecon.
8. USB Port to PC
The USB port allows connecon and communicaon between the USB port on the computer and the UPS unit. The UPS
communicates its status to the PowerPanel ® Personal soware. The USB port is also used for operang the UPS in ECO mode. For
more informaon, refer to secon. ECO Funcon Setup
9. ECO Mode, Surge Protected Outlets
ECO Mode outlets automacally cut power to peripherals when your computer is in Sleep mode or is turned o (USB connecon
required).
10. Outlets Designed for AC Adapters
The UPS unit has 4 widely-spaced outlets so AC power adapters can be plugged into the UPS without overlapping or blocking
adjacent outlets.
ECO FUNCTION SETUP
ECO Funcon
When the ECO funcon is acve the UPS can detect whether the PC that is connected to the USB port is turned on or o. If the PC is
turned o, the UPS will turn o the ECO controlled outlets and cut power to the devices connected to them in order to save power.
Generally, these are peripherals that are not used when the PC is not turned on.
ECO Controlled Outlets
Three of the surge-only outlets are also ECO controlled outlets. When that is connected to the USB port is turned o, UPS the PC the
will turn o the ECO controlled outlets to save energy.
ECO Setup
1. The factory default seng is OFF. ECO mode can only be enabled/disabled and will only be acve when the UPS is receiving
ulity power and not in baery mode.
2. For the EC650/850LCD, press the Mode switch for approximately 3 seconds to enter setup mode and select the ECO funcon.
When the ECO funcon is selected, press the Mode switch for 3 seconds to turn the funcon ON or OFF. Once ON or OFF is
selected, wait 8 seconds for the seng to be conrmed and the LCD screen will return to status mode. For the EC450/550/750G,
press the ECO buon for 3 seconds to turn ON or OFF the ECO funcon.
3. When the ECO funcon is OFF, ulity power from the ECO outlets will always be on. When the ECO funcon is ON, ulity power
from the ECO outlets will turn o if the PC connected to the UPS via the USB port is turned o or if there is no PC is connected to
the UPS via USB.
ECO Indicator
The LED will be blinking when the ECO funcon is turned ON but the PC is either o or not connected. The LED will be solid if the ECO
funcon is turned on and the connected PC is on. The LED is o when the ECO funcon is disabled. See below table for more
informaon.
ECO Indicator
ECO Funcon
ECO Outlet Sta tus
Condion
Solid (green)
ON
With Ulity Power
When PC is ON and USB port on the UPS is connected,
Peripherals will receive power to operate.
Blinking
ON
Without Ulity
Power
When PC is OFF or the USB port on the UPS is not connected,
power to the Peripherals will be turned o.
OFF
OFF
Always with Ulity
Power
When PC is ON/OFF, Peripherals is always ON.
DEFINITIONS FOR ILLUMINATED LED INDICATORS
Power ON
Alarm
CONDITION
On
O
Normal
On
Beep twice
every 30 seconds
Ulity Failure- The UPS is providing power to baery power-supplied outlets from its
baery.
On
Rapid Beeping every
1/2 second
Ulity Failure- The UPS is providing baery power. Rapid beeping indicates the unit will
run out of power shortly.
O
Constant tone
Baery Overload - Occurs when connected equipment exceeds the listed capacity of the
UPS Turn the UPS o, unplug at least one piece of equipment from baery outlets, wait .
10 seconds, reset the circuit breaker and turn the unit on.
INPUT voltage meter: This meter measures the AC voltage that the UPS system is receiving
from the ulity wall outlet. The UPS is designed to connuously supply connected equipment
with stable output voltage. In the event of a complete power loss, severe brownout, or
over-voltage, the UPS relies on its internal baery to supply consistent 110/120 output voltage.
The INPUT voltage meter can be used as a diagnosc tool to idenfy poor-quality input power.
OUTPUT voltage meter: This meter measures, in real me, the AC voltage that the UPS system
is providing to the computer during normal AC/Ulity Power mode, and baery backup mode.
ESTIMATE RUN TIME: This displays the run me esmate of the UPS with the current battery
capacity and load.
NORMAL icon: This icon appears when the UPS is working under normal condions.
BATTERY icon: During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to
indicate the UPS is operang from its internal baery The alarm will connue to sound during a prolonged brownout or blackout. The .
BATT.CAPACITY meter will show one 20% capacity segment remaining to indicate the UPS's baery nearly out of power. You should is
save les and turn o your equipment immediately.
OVER LOAD icon: This icon appears and an alarm sounds to indicate the baery-supplied outlets are overloaded. To clear the
overload, unplug some of your equipment from the baery-supplied outlets unl the icon turns o and the alarm stops.
BATT. CAPACITY meter: This meter displays the approximate charge level of the UPS's internal baery in 20% increments. During a
blackout or severe brownout, the UPS switches to baery power (the BATTERY icon appears) and the baery charge level decreases.
LOAD CAPACITY meter : This meter displays the approximate output load level of the UPS baery outlets in 20% increments.
INSTALLING YOUR UPS SYSTEM
IMPORTANT SAFETY WARNINGS
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
The LCD display indicates a variety
of UPS operational conditions. All
descriptions apply when the UPS is
plugged into an AC outlet and turned
on or when the UPS is on battery.
PRODUCT REGISTRATION
EC650LCD (8 outlets)
EC850LCD (12 outlets)
EC4 / EC550G (8 outlets) 50G
EC750G (12 outlets)

Termékspecifikációk

Márka: CyberPower
Kategória: UPS
Modell: EC650LCD

Szüksége van segítségre?

Ha segítségre van szüksége CyberPower EC650LCD, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek