1. Introduction
Module A-165 (Dual Trigger Modifier)contains two
separate trigger modifiers, to use with logical / digital
levels (Gate, Clock, Trigger). Each half of the module
enables signals generated by the A-100 to communi-
cate with other instruments (such as an external se-
quencer), or is simply used where you want to reverse
a trigger polarity.
Whatever signal is patched into the input is inverted by
the module, and fed out of the Inv. Out (inverted
output) socket.
At the same time, a trigger signal of roughly 50 ms is
generated every time an edge of the trigger pulse is
sensed (negative as well as positive). This trigger
signal is available at the +/- output.
Two LEDs act as indicators showing the level of signal
available at the two outputs.