1
IMPORTANT:
IMPORTANT:
Go to www.extron.com for the
complete user guide, installation
instructions, and specifications.
AXI 016 • Setup Guide
This guide provides basic instructions for an experienced technician to install the AXI 016 Audio Expansion Interface. The AXI016
is a pure breakout device that provides 16 line-level outputs for EXP-enabled devices. The AXI016 is simple to use with no DSP
processing hardware controls. For additional information and specications, go to www.extron.com.
NOTES:
• EXP-enabled devices are devices that contain an Extron EXP port for routing 16 bidirectional channels of digital audio.
• In this guide, “EXP-enabled devices” and “EXP devices” are used interchangeably.
Disconnect Power and Mount the AXI 016
Disconnect power from the AXI 016 and power off all devices that will be connected to it. The AXI 016 is housed in a half-rack
width, 6-inch deep, 1U-high metal enclosure that can be rack mounted, set on a rack shelf, or placed on a table with the provided
rubber feet. Select a suitable mounting location, then choose an appropriate mounting option.
Rear Panel Connections
AXI 016
910
11 12
1
2
3
4
OUTPUTS
EXP INPUT
POWER
12V
0.7 A MAX
13
14
15 16
5
6
7
8
EXP THRU
PRIMARY
DEVICE
SECONDARY
DEVICE
INPUT THRU
EXP
AUDIO EXPANSION INTERFACE
AXI 016
CLIP
SIGNAL
1 2 3 4
5
6 7
8 9 10 11
12
OUTPUTS
13 14 15
16
A B D
C
A B
C
Figure 1. AXI 016 Rear Panel Connections
A
Power Inlet
B
Analog Audio Outputs
C
EXP Input Port and LED
D
EXP Thru Port and LED
A
12 VDC Power Inlet — Connect the 12 VDC power supply to the rear panel captive screw power inlet. Then, plug
the power cable into the IEC inlet on the external power supply (see figure 2 and the following Attention notices).
Rear Panel
Power Receptacle
DC Power Cord
Captive Screw
Connector
Ground
all devices.
External
Power Supply
12 VDC, 1.5 A max.
– Return
+12 VDC input
Ridged
Smooth
1A MAX
100-240V 50-60Hz
Figure 2. Connecting the External Power Supply
ATTENTION:
• Always use a power supply provided by or specified by Extron. Use of an unauthorized power supply voids all regulatory
compliance certification and may cause damage to the supply and the end product.
• Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non autorisée
annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.

2
ATTENTION:
• If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked “Class
2” or “LPS” and rated output 12VDC, 0.7 A minimum, 48 or 56 VDC (PoE), minimum 0.35 A.
• Si ce produit n’est pas fourni avec une alimentation, il doit être utilisé avec une source d’alimentation certifiée
UL de classe 2 ou LPS avec une tension nominale 12 Vcc, 0,7 A minimum (PoE), 48 Vcc (PoE), or 56 Vcc (PoE)
0,35Aminimum.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The
power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location,
Pollution Degree2, secured to the equipment rack within the dedicated closet, podium, or desk.
• Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d’aération
ou dans les cavités murales. La source d’alimentation doit être située à proximité de l’équipement de traitement
audiovisuel dans un endroit ordinaire, avec un degré2 de pollution, fixé à un équipement de rack à l’intérieur d’un
placard, d’une estrade, ou d’un bureau.
• The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70,
article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
• Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code
ANSI/NFPA70, article725, et au Canadian Electrical Code, partie1, section16. La source d’alimentation ne devra pas
être fixée de façon permanente à une structure de bâtiment ou à une structure similaire.
B
Analog Audio Outputs — Use 6-pole, 3.5 mm captive screw connectors to connect up to 16 balanced or
unbalanced line-level devices. Balanced or unbalanced mono devices can also be connected using 3-pole, 3.5 mm
captive screw connectors.
Tip
Sleeve
Tip
Sleeve
Tip
Slee
ve
Ring
Tip
Slee
ve
Ring
6-pole Audio OUTPUT Wiring
Balanced Output Unbalanced Output
NO Ground Here
NO Ground Here
3-pole Audio OUTPUT Wiring
Unbalanced Output
Tip
Sleeve
NO Ground Here
Balanced Output
Tip
Sleev
e
Ring
Figure 3. Audio Output Wiring
ATTENTION :
• For unbalanced audio outputs, connect the sleeves to the ground contact. DO NOT connect the sleeves to the
negative (-) contacts.
• Pour l’audio asymétrique, connectez les manchons au contact au sol. NE PAS connecter les manchons aux
contacts négatifs (–).
C
EXP Input Port and LED — This RJ-45 EXP port connects the AXI 016 to the EXP port of a primary EXP device.
The Expansion output channels of the primary EXP device are sent to the AXI016 line outputs (see Connecting
a Primary Device to the EXP Input Port on the next page). The LED to the right of the EXP INPUT port blinks to
indicate a primary EXP device is connected.
NOTE: A primary EXP device is a device that has been set as a Primary Unit in DSP Configurator (see the
DMP 128 Plus User Guide for more information regarding primary and secondary EXP devices). DMP 128 Plus units are
set to primary by default.
D
EXP Thru Port and LED — This RJ-45 EXP port connects the Expansion output channels of a secondary EXP
device to the AXI016. When a primary EXP device is connected to the EXP INPUT port, the Expansion output
channels of the secondary EXP device connected to the EXP THRU port are sent through the AXI016 to the Expansion
input channels of the primary device connected to the EXP INPUT port (see Connecting a Primary EXP Device and
Secondary EXP Device on page4). If no primary EXP device is connected to the EXP INPUT port, the Expansion
output channels of the secondary EXP device connected to the EXP THRU port are sent to the AXI016 line outputs
(see Connecting a Secondary EXP Device to the EXP Thru Port on page6). The LED to the right of the EXP
THRU port lights solid to indicate a secondary EXP device is connected.

3
AXI 016 • Setup Guide (Continued)
NOTE: A secondary EXP device is a device that has been set as a Secondary Unit in DSP Configurator (see the
DMP 128 Plus User Guide for more information regarding primary and secondary EXP devices). DTP CrossPoint units
are set to secondary by default.
Front Panel Features
AXI 016
910
11 12
1
2
3
4
OUTPUTS
EXP INPUT
POWER
12V
0.7 A MAX
13
14
15 16
5
6
7
8
EXP THRU
PRIMARY
DEVICE
SECONDARY
DEVICE
INPUT THRU
EXP
AUDIO EXPANSION INTERFACE
AXI 016
CLIP
SIGNAL
1 2 3 4
5
6 7
8 9 10 11
12
OUTPUTS
13 14 15
16
A B D
C
A B
C
Figure 4. AXI 016 Front Panel Features
A
Power Indicator LED
B
EXP Indicator LEDs
C
Output Signal and Clip LEDs
A
Power Indicator LED — This green LED lights solid when the AXI016 is powered and fully operational.
B
EXP Indicator LEDs — The green Input LED blinks to indicate a primary EXP device is connected to the rear-panel
EXP INPUT port. The green Thru LED lights solid to indicate a secondary EXP device is connected to the rear-panel
EXP THRU port.
C
Output Signal and Clip LEDs — Sixteen pairs of stacked green and red LEDs light steadily when signal is present
and increase in intensity from -60 dBFS (lowest intensity, signal presence indication) to -3 dBFS (full brightness). The
red clip LEDs light solid to indicate clipping when a signal exceeds -3 dBFS. The red clip LEDs stay lit for one second
after clipping ceases.
Application and Signal Flow Diagrams
The following diagrams display the different signal ows when primary and secondary EXP-enabled devices are connected to the
AXI 016.
NOTE: Daisy-chaining two or more AXI 016 units together is not supported.
Connecting a Primary Device to the EXP Input Port
The diagram below displays the AXI 016 signal ow when only a primary EXP device, such as the DMP128Plus, is connected to
the EXP INPUT port of the AXI016.
• All 16 Expansion output channels of the primary device are routed to the line outputs of the AXI016 (see path A1 in figure 5).
• Expansion output channel 1 of the primary device is routed to the AXI 016 line output 1, and so on.
Termékspecifikációk
Márka: | Extron |
Kategória: | nincs kategorizálva |
Modell: | AXI 016 |
Szüksége van segítségre?
Ha segítségre van szüksége Extron AXI 016, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva Extron
2 Április 2025
2 Április 2025
2 Április 2025
2 Április 2025
11 Január 2025
11 Január 2025
7 Január 2025
7 Január 2025
7 Január 2025
4 Január 2025
Útmutatók nincs kategorizálva
- nincs kategorizálva Kstar
- nincs kategorizálva Mestic
- nincs kategorizálva Seco-Larm
- nincs kategorizálva Endorphin.es
- nincs kategorizálva Synamodec
- nincs kategorizálva DeLonghi
- nincs kategorizálva Sherlock
- nincs kategorizálva Proel
- nincs kategorizálva Genius
- nincs kategorizálva Velux
- nincs kategorizálva Zenit
- nincs kategorizálva Videotel Digital
- nincs kategorizálva Tanaka
- nincs kategorizálva Hoffman
- nincs kategorizálva Bintec-elmeg
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025