LG+5V - RF Boiler Control
Press the “SYNC“ button for 3 seconds
until LED starts ashing
The LG+5V is ready to be paired
with your compatible SALUS device.
6. Push t boiler control into housing.
7. Power up the boiler and check the
correct operation. Note: Once paired please close the boiler control panel
Installation Pairing the LG + 5V
5. Connect the electrical plug.
3 Sec

Introduction
The LG+5V boiler module 868MHz is a receiver with 5V DC to control ON/
OFF of Boiler or other heat system via the RF signal transmitted from the
thermostat.
Product Compliance
This product complies with the essential requirements and other
relevant provisions of Directives (RED) 2014/53/EU and 2011/65/EU.
The full text of the EU Declaration of Conformity is available at the
following internet address: www.salus-controls.com.
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your
device completely dry. Disconnect your device before cleaning it with
a dry cloth.
868MHz-868.8MHz; <13dBm
Terminal connections
The LG+V5 is compatible with the following SALUS products
RT310TX
RT510TX iT500TR
RT310iTX
ERT20TX
Compatibility
Terminal Identier Description
1 DC + DC power supply (+)
2 DC - DC power supply (-)
3 COM Common input
4 NO Normal Open
5 NC Normal Closed
Installation
Switch Position
1
1 2 3
2
3
The boiler receiver is o.
AUTO. RX will automatically
receive the RF signal from your
compatible SALUS device and
controls relay output.
Manual mode - Manual Override
(Note this mode will run your boiler continuously)
1. Ensure boiler is isolated and switched o.
2. Pull down control panel cover.
3. Remove existing mechanical timer and unscrew from plate.
4. Reverse the procedure to install the RXBC5V.
Note: When removing blanking plate also remove visible
thermostat link plug do not remove any internal link.
i
Termékspecifikációk
Márka: | Salus |
Kategória: | Vevő |
Modell: | LG+5V |
Szüksége van segítségre?
Ha segítségre van szüksége Salus LG+5V, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Vevő Salus
30 Augusztus 2024
19 Július 2024
Útmutatók Vevő
- Vevő ESX
- Vevő TIC
- Vevő Universal Audio
- Vevő Rockford Fosgate
- Vevő Axis
- Vevő Ampeg
- Vevő DB Technologies
- Vevő TOA
- Vevő LD Systems
- Vevő Aurel
- Vevő Cambridge
- Vevő Audioengine
- Vevő Renegade
- Vevő Russound
- Vevő Sinus Live
Legújabb útmutatók Vevő
9 Április 2025
9 Április 2025
5 Április 2025
5 Április 2025
2 Április 2025
2 Április 2025
2 Április 2025
31 Március 2025
31 Március 2025
30 Március 2025