3CONNECTION DIAGRAMS
2
V3IS00263–100
DIMENSIONS
1User Manual
DIGITAL FREQUENCY METER
Read all the instructions carefully
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: info@vemer.it - web site: www.vemer.it
Mod.EVF-2DIN
EVF-R
EVF-2DIN
EVF-R
36 60
45
65
88
5
72 75
72
66
EVF-2DIN
EVF-R
EVFis an electronic device to measure frequencies in single-phase
systems.
Code Model Description
VM258100EVF-2DIN Frequency meter 2DIN
VM325800EVF-R Frequency meter 72x72mm
SAFETY WARNINGS
During the installation and operation of the device, proceed in accordance
with the instructions below:
1) The device should be installed by a competent operator following the
connection diagrams carefully
2) Do not power or connect the device if any part of it is damaged
3) The device should be installed in a panel from which no access can be
gained to the terminals after installation
4) The electrical system of the building in which the instrument is to be
installed should have a switch and a protective device against over-currents
5) The device is designed for installations with over-voltage category III and
pollution level 2, in accordance with the EN 61010-1 standard.
6) The device must be installed and put into operation in accordance with the
current regulations regarding electrical systems.
TECHNICAL SPECIFICATIONS
• Power supply
- 230 V AC (-15% ÷ +10%) 50/60Hz
- maximum consumption: 2 VA
• Frequency measurements:
- measurement range: 20 ÷ 100 Hz
- resolution: 0.1 Hz
- accuracy: ± 0.5% of full scale ± 1 digit (from 3% to 100% of F.S.)
- maximum power consumption: 2 VA
• Measurement input:
- minimum voltage: 20 V
- maximum voltage: 600 V
- input impedance: 2 Mohm
• Terminals for links:
- connection blocks for cables with 6 mm² maximum cables section for EVF-
2DIN
- plug-in terminal block for cables with 2.5 mm² maximum cables section up
for EVF -R
• 3-digits 7-segments LED display for viewing
• Operating temperature: -10°C to + 45°C
• Storage temperature: -20°C to + 70°C
• Relative humidity: 10% to 90% non-condensing
• Insulation: power supply circuits and electrically insulated measurement at
the level of main insulation (EN 61010-1). Accessible parts and other insulated
terminals at reinforced insulation level
• Protection degree: IP20 / IP51 on the front
4OPERATION
During normal operation, the device displays the
measured value of the frequency.
Error messages
• Memory error: EEE
Indicates a damage of the device that affect the
operation
• Overload Error: KKK
Indicates that the frequency is higher than the
maximum allowed value: f > 99.9 Hz
Reset is automatic
• Error: 000
Indicates that the measured frequency is lower than
20 Hz
REFERENCE STANDARS
Conformity to the EU directives:
2014/35/UE (LVD), 2014/30/UE (EMCD)
is declared with reference to the following harmonised standards:
• EN 61010-1, EN 61000-6-2 and EN 61000-6-4
03-2018
Hz
21
65
3 4
7 8
max. 600V~
2
3
0
V
~
5
0
-
6
0
H
z
~
5 4312
2
3
0
V
~
5
0
-
6
0
H
z
~
Hz
max. 600V~
Termékspecifikációk
| Márka: | Vemer |
| Kategória: | nincs kategorizálva |
| Modell: | EVF-R |
Szüksége van segítségre?
Ha segítségre van szüksége Vemer EVF-R, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók nincs kategorizálva Vemer
4 Október 2024
3 Október 2024
2 Október 2024
22 Szeptember 2024
22 Szeptember 2024
22 Szeptember 2024
21 Szeptember 2024
18 Szeptember 2024
16 Szeptember 2024
13 Szeptember 2024
Útmutatók nincs kategorizálva
Legújabb útmutatók nincs kategorizálva
10 Április 2025
10 Április 2025
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025