Oldal 1/3

• Quietoperation,32db
• Fanspeedsproportionaltotemperatureofenclosure
toextendfanlife,reducedustandmaintenance
• Proprietaryblowersprovidehighstaticpressureto
maintainairowevenincrowdedracks.
• Forsmallerracksystemsandcredenzaswherespace
isatapremiumandquietoperationisamust
• Compactdesignoccupiesonly1rackspace
• 1/2rackmodelalsoavailable
QBP Series Quiet Blower Panel
96-01163/rev1b/5-24-12
The QBP-2 is quieter, yet puts out more CFM than
other 1 space fan panels
96-01163/rev1b/5-24-12/QBPSeriesQuietBlowerPanel
EXCEPTIONAL SUPPORT & PROTECTION™
Features
c u s t o m i z a b l e s p e c i f i c a t i o n c l i p s a v a i l a b l e a t m i d d l e a t l a n t i c c o m .
US: New Jersey • California • Illinois • Voice: 973-839-1011 Fax: 973-839-1976 • middleatlantic.com
Canada: Ontario • British Columbia • Voice: 613-836-2501 Fax: 613-836-2690 • middleatlantic.ca
QBP Series
Architects’ and Engineers’ Specifications
EIA/TIA Compliant
QBP-2A
(invertedpositiontodrawairfromthetop)
HR-QBP-1
(1/2rackmodel)
QBP-2A
HR-QBP-1

QBP-2 basic dimensions
All dimensions in inches unless otherwise noted [All dimensions in brackets are in millimeters]
US: New Jersey • California • Illinois • Voice: 973-839-1011 Fax: 973-839-1976 • middleatlantic.com
Canada: Ontario • British Columbia • Voice: 613-836-2501 Fax: 613-836-2690 • middleatlantic.ca
1.75 [44]
1 RACKS CEPA
10.11 [257]
8.69 [221]
5.76 [146]
8.69 [221] 5.46 [139]
8.36 [212] fre
19.00 [483]
Ø 5.20 [132]
FRONT VIEW
TOP VIEW
BOTTOM VIEW
SIDE VIEW
AIRFLOW DIRECTION
AIRFLOW DIRECTION
AIRFLOW DIRECTION
TEMPER URE PROBE, 9FTAT
NOTE(S):
1. N SPECIFICATIONS:FA
2. QBP-2A SHOWN. ANODIZED VERSION
CONTAINS “A” SUFFIX. INTERN IONAL AT
MODELS, IQBP-2 AND IQBP-2A, COME
WITH UNIVERSAL VOLTAGE PLUG-IN
POWER SUPP AND ADAPTERS.LY
AIRFLOW: 100 CFM [2.8 M³/MIN]
CURRENT DRA 840mA @ 12 VDCW:
SOUND LEVEL: 32 dBA @ 1 M
STATIC PRESSURE: 0.31 IN H
²0 [77.22 Pa]

QBP-1 basic dimensions
All dimensions in inches unless otherwise noted [All dimensions in brackets are in millimeters]
TEMPERATURE PROBE, 9FT
NOTE(S):
FAN SPECIFICATIONS:
AIRFLOW: 50 CFM [1.4 M3/MIN]
CURRENT DRA 420mA @ 12 VDCW:
SOUND LEVEL: 28 dBA @ 1 M
S TIC PRESSURE: 0.31 IN H20 [77.22 Pa]TA
AIRFLOW DIRECTION
AIRFLOW DIRECTION
FRONT VIEW
TOP VIEW
BOTTOM VIEW
SIDE VIEW
1.72 [ 44 ]
1 RACKSPACE
10.40 [ 264 ]
5.50 [140]
5.76 [ 146]
8.36[ 212]
10.11 [257]
8.69 [ 221]
US: New Jersey • California • Illinois • Voice: 973-839-1011 Fax: 973-839-1976 • middleatlantic.com
Canada: Ontario • British Columbia • Voice: 613-836-2501 Fax: 613-836-2690 • middleatlantic.ca
Termékspecifikációk
Márka: | Middle Atlantic |
Kategória: | Hardverkoeling |
Modell: | IQBP-2A |
Szüksége van segítségre?
Ha segítségre van szüksége Middle Atlantic IQBP-2A, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók Hardverkoeling Middle Atlantic
27 December 2024
27 December 2024
27 December 2024
26 December 2024
26 December 2024
26 December 2024
26 December 2024
26 December 2024
26 December 2024
26 December 2024
Útmutatók Hardverkoeling
- Hardverkoeling AZZA
- Hardverkoeling Dynatron
- Hardverkoeling Corsair
- Hardverkoeling Intel
- Hardverkoeling Thermalright
- Hardverkoeling Akasa
- Hardverkoeling Be Quiet!
- Hardverkoeling EK Water Blocks
- Hardverkoeling DeepCool
- Hardverkoeling Lian Li
- Hardverkoeling Evolveo
- Hardverkoeling AeroCool
- Hardverkoeling Raijintek
- Hardverkoeling SilverStone
- Hardverkoeling Emerson
Legújabb útmutatók Hardverkoeling
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
8 Április 2025
8 Április 2025
8 Április 2025
8 Április 2025
8 Április 2025
8 Április 2025