Használati útmutató Monacor MH-950/2
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Monacor MH-950/2 (6 oldal) a mikrofon kategóriában. Ezt az útmutatót 14 ember találta hasznosnak és 7.5 felhasználó értékelte átlagosan 4.9 csillagra
Oldal 1/6

IP65 IP67
SPECIFICATION
MODEL
OUTPUT
DC VOLTAGE
24V
48V
54V
CONSTANT CURRENT REGION
Note.4
12 ~ 24V
24 ~ 48V
27 ~ 54V
RATED CURRENT
5A
2.5A
2.3A
RATED POWER
120W
120W
124.2W
RIPPLE & NOISE (max.) Note.2
150mVp-p
200mVp-p
200mVp-p
VOLTAGE ADJ. RANGE Note.6
22 ~ 27V
43 ~ 53V
49 ~ 58V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer A type only
2.5 ~ 5A
1.2 ~ 2.5A
1.1 ~ 2.3A
VOLTAGE TOLERANCE Note.3
±1.0%
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME Note.8
1200ms,50ms/115VAC 500ms,50ms/230VAC at full load ; B type 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
HOLD UP TIME (Typ.)
12ms at full load 230VAC / 115VAC
INPUT
VOLTAGE RANGE Note.5
90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading 50% at 115VAC/230VAC input and output loading 75% at 277VAC input≧ ≧
EFFICIENCY (Typ.)
93%
93.5%
93.5%
AC CURRENT (Typ.)
1.4A / 115VAC 0.6A / 230VAC 0.55A / 277VAC
INRUSH CURRENT (Typ.)
COLD START 60A(t =375width μs measured at % I ) at V50 peak 230 AC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
PROTECTION
OVER CURRENT
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
28 ~ 34V
54 ~ 63V
59 ~ 65V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")℃
WORKING HUMIDITY
20 ~ 95% RH -condensingnon
STORAGE TEMP., HUMIDITY
-40 ~ +80 , 10 ~ 95% RH℃
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50 )℃ ℃
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
SAFETY STANDARDS Note.7
UL8750, CSA C22.2 No. 250.0-08, ENEC, TUV EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1,
J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3≧
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERS
MTBF
192.2K hrs min. MIL-HDBK-217F (25 )℃
DIMENSION
220*68*38.8mm (L*W*H)
PACKING
1.12Kg; 12pcs/14.4Kg/0.8CUFT
NOTE
℃
File Name:HLG-120H-SPEC 2017-11
120W Single Output Switching Power Supply
HLG- 120 H series
■
Baua rt g epru ft
Sic h erhe it
egel m a g e
od o s
be w ac g
www . tuv .co m
ID 2 000 000 00 0
HLG- -120H 24
HLG- -120H 48
HLG- -120H 54
Termékspecifikációk
| Márka: | Monacor |
| Kategória: | mikrofon |
| Modell: | MH-950/2 |
Szüksége van segítségre?
Ha segítségre van szüksége Monacor MH-950/2, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók mikrofon Monacor
14 Augusztus 2024
14 Augusztus 2024
13 Augusztus 2024
13 Augusztus 2024
13 Augusztus 2024
13 Augusztus 2024
12 Augusztus 2024
12 Augusztus 2024
11 Augusztus 2024
11 Augusztus 2024
Útmutatók mikrofon
- mikrofon Ambient
- mikrofon ART
- mikrofon The T.bone
- mikrofon Majestic
- mikrofon Gravity
- mikrofon Clockaudio
- mikrofon Auray
- mikrofon Ambient Recording
- mikrofon Skytec
- mikrofon Dorr
- mikrofon Scope Labs
- mikrofon Peavey
- mikrofon Williams Sound
- mikrofon Perfect Choice
- mikrofon BOYA
Legújabb útmutatók mikrofon
10 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
9 Április 2025
2 Április 2025
2 Április 2025
2 Április 2025